Riverview J I WSEC Air Barrier Testing Report <br /> Report Glossary <br /> air-leakage*, n-the movement/flow of air through the building envelope,which is driven by either or both positive <br /> (infiltration)and negative(exfiltration)pressure differences across the envelope. <br /> air-leakage rate*,n-the volume of air movement/unit time across the building envelope including airflow through joints, <br /> cracks, and porous surfaces, or a combination thereof driven by mechanical pressurization and depressurization, natural <br /> wind pressures,or air temperature differentials between the building interior and the outdoors,or a combination thereof. <br /> building envelope*, n-the boundary or barrier separating different environmental conditions within a building and from <br /> the outside environment. <br /> effective leakage area*,n-the area of a hole,with a discharge coefficient of 1.0,which,with a 75 Pa pressure difference, <br /> leaks the same as the building,also known as the sum of the unintentional openings in the structure. <br /> flow coefficient, n-the constant parameter of the power law equation that relates flow to differential pressure across a <br /> building envelope.It represents the theoretical flow rate that exists at a differential pressure of 1 Pa. <br /> pressure exponent, n -the exponent applied to the pressure parameter of the power law equation that relates flow to <br /> differential pressure across a building envelope.The exponent is a value between 0 and 1 that is indicative of how turbulent <br /> the air flow is.A value of 1 represents totally laminar flow. <br /> * Definition as given in ASTM E779-15 Standard Method for Determining Air Leakage Rate by Fan Pressurization. <br /> Page 8 ) 8 <br />