Drew Martin <br /> From: Drew Martin <br /> Sent: Tuesday,June 29, 2021 3:35 PM <br /> To: Taylor Fjeran; Steve Banks <br /> Cc: Kurt Keck; Michael List; David Foster <br /> Subject: RE: B2006-008 2110 Rockefeller Detached Garage Permit <br /> Taylor, <br /> I've reviewed the approved drawings and the sketch, and identified three issues as follows: <br /> 1. The wall should be a 1-hour rated from both directions. A minimum 5/8"exterior-grade GWB should be <br /> provided outside the exterior panel sheathing under the siding. The rated north and south walls require <br /> inspection ad approval prior to covering. <br /> 2. The roof eaves on the north and south sides are limited to 4" measured from the face of the wall. Vents should <br /> not be provided on these sides. <br /> 3. Detail 3/04 states that the roof sheathing on the rake edges can extend up to 18 inches without structural <br /> support. This is not correct. Unsupported cantilever sheathing is limited to 9 inches. The rake edges should be <br /> strengthened as needed. <br /> Drew Martin, P.E.,S.E. <br /> Li <br /> iii Associate Engineer—Commercial Plans Examiner I Permit Services <br /> 425.257.8813 13200 Cedar Street, 2nd Floor, Everett,WA 98201 <br /> EVERETT Hours: M/W/Th/F: 7:30am-12:OOpm & 1:00pm-3:OOpm;Tu: 1:OOpm-3:OOpm <br /> everettwa.gov I Facebook I Twitter <br /> From:Taylor Fjeran<taylor.fjeran@gmail.com> <br /> Sent:Tuesday,June 29, 2021 2:30 PM <br /> To:Steve Banks<SBanks@everettwa.gov>; Drew Martin <dmartin@everettwa.gov> <br /> Cc: Kurt Keck<KKeck@everettwa.gov>; Michael List<list.micha@gmail.com> <br /> Subject: B2006-008 2110 Rockefeller Detached Garage Permit <br /> Hello Steve and Drew, <br /> I was referred to you both from the permit service desk as our building inspector, Kurt Keck is out of town right now.We <br /> are building a detached garage (Permit#B2006-008), and it appears that the approved permit did not have any fire- <br /> assembly listed. Kurt brought this to our attention and requested that we provide a document with fire-rated materials <br /> per IRC302.1. I've attached the document that our designer provided with the fire-rated materials.We were planning on <br /> asking Kurt this in person today during our exterior sheath inspection, but he is currently on vacation. Our contractor is <br /> going to start siding tomorrow(Wednesday), but before he does, we were hoping you could confirm that the attached <br /> fire-assembly is in compliance.Thank you! <br /> 1 <br />