T <br /> Mr. Joel Haack <br /> Haack Brothers Homes <br /> Plan Check Number: C2004-001, Second Building Review <br /> August 11, 2020 <br /> width is correct. The drawings should be coordinated for consistency. See IBC Section <br /> 107.2.1. <br /> Gravity System: <br /> 8. This comment has not been addressed. The original comment stated that the framing plans <br /> should specify hardware connections for the beams, headers, and joists. The provided <br /> response does not appear to address the comment. The plans do not appear to provide the <br /> required connection hardware. See IBC Sections 107.2.1, 1603.1, and 1604.4. The following <br /> comments should be addressed: <br /> a. The plans do not appear to clearly show all gravity framing. The load paths cannot be <br /> verified. This includes vertical components (e.g., posts) of the system. Headers and beams <br /> appear to be missing. Joist framing appears to be required in many locations without clear <br /> specification of the framing extents and sizes. The plans should be revised to provide a <br /> complete and clear load path to the foundations. <br /> b. Connections should be specified between all framing members where direction bearing is <br /> not provided. The make and model of proprietary hardware should be stated. <br /> Lateral System: <br /> 14.This comment has not been completely addressed. Detail 14/S-2 (previously Detail 5/S-1) <br /> shows an ordinary steel moment frame. Additional calculations and details are required for this <br /> portion of the lateral system. See IBC Sections 1604.1, 1604.4, 1613.1, and 2205.2.1.2. The <br /> following comments should be addressed: <br /> a. The design of the column connections to the wood-framed structure are required to comply <br /> with the seismic detailing requirements of AISC 341-10 Sections D2.6a and D2.6b. Note <br /> that 2014 version of this standard may provide preferable design criteria and is permitted <br /> for use per IBC Section 104.11. <br /> b. The proposed lateral system (i.e., steel moment frame to wood shear wall) is not vertically <br /> continuous to the foundation (i.e., in-plane offset between the frame and walls), and <br /> constitutes a Type 4 Vertical Structural Irregularity per ASCE 7-10 Table 12.3-2. The <br /> supporting wood posts, and the connections between the steel and wood posts and to the <br /> foundation, should be designed including overstrength per Section 12.3.3.3. The load <br /> combinations of Section 12.4.3.2 including vertical load effects of Section 12.4.2.2 should be <br /> used. <br /> c. Continuing with the previous comment, steel column bases should be provided with <br /> collectors transferring the shear loads to the wood shear walls. The collectors and their <br /> connections to both the column bases and the walls should be designed for a 25% increase <br /> per ASCE 7-10 Section 12.3.3.4. <br /> Miscellaneous: <br /> 20.This comment has not been addressed. The original comment addressed Details 4/A5.2 and <br /> 6/A5.2 show guards and their connections to the structure. The details do not appear to <br /> include revisions as stated in the response. The calculations pages referenced in the response <br /> were not included. See IBC Section 1607.8.1. The following comments should be addressed: <br /> O3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.