My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2401 TAYLOR DR Geotech Report 2022-10-25
>
Address Records
>
TAYLOR DR
>
2401
>
Geotech Report
>
2401 TAYLOR DR Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 2:01:33 PM
Creation date
3/2/2022 8:55:30 AM
Metadata
Fields
Template:
Address Document
Street Name
TAYLOR DR
Street Number
2401
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2401 Taylor Drive Geotechnical Engineering Study <br /> Everett, Washington <br /> respectively. The seismic surcharge should be modeled as a rectangular distribution with the <br /> resultant applied at the midpoint of the walls. <br /> The lateral pressures presented above are based on the conditions of a uniform backfill consisting <br /> of excavated on-site soils, or imported structural fill compacted to 90 percent of ASTM:D 1557. <br /> A higher degree of compaction is not recommended, as this will increase the pressure acting on <br /> the walls. A lower compaction may result in settlement of the slab-on-grade or other structures <br /> supported above the walls. Thus,the compaction level is critical and must be tested by our firm <br /> during placement. Surcharges from adjacent footings or heavy construction equipment must be <br /> added to the above values. Perimeter footing drains should be provided for all retaining walls, <br /> as discussed under the "Drainage Considerations" section of this report. <br /> It is imperative that proper drainage be provided so that hydrostatic pressures do not develop <br /> against the walls. This would involve installation of a minimum 1-foot-wide blanket drain to <br /> within 1 foot of finish grade for the full wall height using imported, washed gravel against <br /> the walls. <br /> Passive Resistance and Friction Factors <br /> Lateral loads can be resisted by friction between the foundation and the natural soils or <br /> supporting structural fill soils, and by passive earth pressure acting on the buried portions of the <br /> foundations. The foundations must be backfilled with structural fill and compacted to at least <br /> 95 percent of the maximum dry density to achieve the passive resistance provided below. We <br /> recommend the following allowable design parameters for permanent walls: <br /> • Passive equivalent fluid = 350 pcf <br /> • Coefficient of friction =0.3 <br /> Drainage Considerations <br /> All perimeter footing walls should be provided with a drain at the base of the footing elevation. <br /> Drains should consist of rigid, perforated, polyvinyl chloride (PVC) pipe surrounded by washed <br /> pea gravel. The level of the perforations in the pipe should be set at or slightly below the bottom <br /> of the footing and the drains should be constructed with sufficient gradient to allow gravity <br /> discharge away from the buildings. Roof and surface runoff should not discharge into the footing <br /> drain system but should be handled by a separate, rigid, tightline drain. In planning, exterior <br /> grades adjacent to foundations should be sloped downward away from the structures to achieve <br /> surface drainage. <br /> November 6, 2019 SONDERGARRD GEOSCIENCES, PLLC <br /> 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.