Rucker Hill—3 Lot Short Plat <br /> No.3—Under ground Detention Pipes/Manias <br /> Nfuinlenance Defect Conditions When Maintenance is Needed Results Expected When <br /> Component Maintenance is <br /> Performed <br /> Storage Area Plugged Air Vents One-half of the cross section ofa vent is blocked Vents open and <br /> at any point or the vent is damaged. functioning. <br /> Debris and Sediment The average sediment depth measured at All sediment,debris, <br /> multiple locations exceeds Ifl%ofthe detention and organic matter <br /> pipe diameter(or the depth of the storage area) removed from storage <br /> or the sediment depth measured at a any single area.. <br /> point exceeds 15%of the pipe diameter. <br /> (Example:The sediment depth in a 60-inch <br /> diameter detention pipe is measured at three <br /> locations.The sediment would need to be <br /> removed if the average depth of the three <br /> measurements is at least 6 inches or if the depth <br /> of any single measurement is at least 9 inches. <br /> Joints Between Any openings or voids at section joint allowing All joints between <br /> Tank/Pipe Section material to seep into or water to leak out of tank/pipe sections are <br /> facil ity. sealed. <br /> Note:This may need an engineering analysis to <br /> aasets the structural stability. <br /> Tank Pipe Ben:Out Any part of tank/pipe is bent out of shape more Tank/pipe section is <br /> of Shape than 10%of its design shape. repaired or replaced to <br /> Note:This may need an engineering analysis to design- <br /> assess the structural stability. <br /> Tank/Pipe Material Any visible holes or cracks wider than a quarter Tank;pipe is repaired or <br /> of an inch or evidence of material seeping into nr replaced to design <br /> water leaking out of pipe wall,or qualified specifications and is <br /> maintenance or inspection personnel determine structurally sound. <br /> that tank/pipe is not structurally sound. <br /> Access Hole Cover Not in Place Cover is missing or only partially in place.Any Manhole is closed. <br /> open manhole requires maintenance. <br /> Locking Mechanism Locking mechanism cannot he opened or lock Mechanism or lock <br /> Not Working bolts cannot be removed by one maintenance bolts open with proper <br /> person with proper hand tools. hand tools. <br /> Cover Difficult to One maintenance person cannot remove lid after Cover can be removed <br /> Remove applying normal lifting pressure with proper and reinstalled by one <br /> hand tools. intent is to keep cover from sealing maintenance person <br /> off access to maintenance. with proper hand tools. <br /> Ladder Rungs Unsafe Ladder is unsafe due to missing rungs, Ladder meets design <br /> cracked/broken rungs,misalignment,rungs not standards and allows <br /> securely attached to structure~wall,rust,or maintenance person <br /> cracks. sale access. <br /> Catch Basins See-Catch Basins.' See--Catch Basins'.(No.5). Sec-Catch Basins- <br /> (No.5) (No.5). <br /> Standpipe, Obstructions,Damaged, Sec-Control Structure/Flow Rcstrictors"(No.4) Sec-Control <br /> Cicanout Gate, or Missing Structure/Flow <br /> Orifice Plate Restrictors"(No.4) <br /> WESTERN ENGINEERS,INC. 2 PROJECT: 16-1584-A <br />
The URL can be used to link to this page
Your browser does not support the video tag.