Laserfiche WebLink
• <br /> • Rucker Hill—3 Lot Short Plat <br /> No.4—Control Structure/Flow Resirictors <br /> Maintenance Defect Condition When Maintenance is Needed Results Expected <br /> Component When Maintenance is <br /> Performed <br /> Standpipe Obstructions Any material blocking(or having the potential of Pipe is free of all <br /> blocking)the pipe overflow. obstructions and works <br /> as designed. <br /> Structural Damage Structure is not securely attached to manhole Structure is securely <br /> wall. attached to wall and <br /> outlet pipe. <br /> Structure is not in upright position(allow up to Structure is in correct <br /> ID%from plumb). position. <br /> Connections to outlet pipe arc not watertight and Connections to outlet <br /> show signs of rust. pipe are water tight; <br /> structure repaired or <br /> replaced and works as <br /> designed. <br /> Any holes other than designed boles in the Structure has no holes <br /> structure. other than designed <br /> holes. <br /> C:canoL:LL Gate Damaged or Missing, Cleanout gate is not watertight or is missing. Gate is watertight and <br /> works as designed_ <br /> Gate cannot be moved up and down by one Gate moves up and <br /> maintenance person. down easily and is <br /> watertight. <br /> Chain/rod leading to gate is missing or damaged. Chain is in place and <br /> works as designed. <br /> Gate is rusted over 50 o of its surface area Gate is repaired or <br /> replaced to meet design <br /> standards. <br /> Orifice Plate Damaged or Missing Control device is not working properly due to Plate is in place and <br /> missing,out of place,or bent orifice plate. works as designed.. <br /> Obstructions Any trash,debris,sediment,or vegetation Plate is free ofall <br /> Hocking the plate. obstructions and works <br /> as designed. <br /> Ovcrfl A.Pipc Obstructions Any trash or debris blocking for having the Pipe is free of all <br /> potential of blocking)the overflow pipe. obstructions and works <br /> as designed. <br /> Access Hole Cover Not in Place Cover is missing or only partially in place.Any Manhole is closed. <br /> open manhole requires maintenance. <br /> Locking Mechanism Locking mechanism cannot he opened or lock Mechanism or lock <br /> Not Working bolts cannot be removed by one maintenance bolts open with proper <br /> person with proper hand tools. hand tools. <br /> Cover Difficult to One maintenance person cannot remove lid after Cover can be removed <br /> Remove applying normal lifting pressure with proper and reinstalled by one <br /> hand tools. Intent is to keep cover from scaling maintenance person <br /> off access to maintenance. with proper hand tools. <br /> Ladder Rungs Unsafe Ladder is unsafe due to missing runes, Ladder meets design <br /> cracked/broken rungs,misalignment,rungs not standards and allows <br /> securely attached to structure wall,rust,or maintenance person <br /> cracks. safe access. <br /> WESTERN ENGINEERS,INC. 3 PROJECT: 16-1584-A <br />