My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2201 100TH ST SW AD SYSTEMS 2022-03-07
>
Address Records
>
100TH ST SW
>
2201
>
AD SYSTEMS
>
2201 100TH ST SW AD SYSTEMS 2022-03-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2022 2:19:18 PM
Creation date
3/2/2022 2:15:51 PM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SW
Street Number
2201
Tenant Name
AD SYSTEMS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Envelope Summary ENV-SUM <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Info Project Title: AD Systems Warehouse Addition Date 08/11/2017 <br /> Applicant Information. Provide contact information for individual who can For Building Department Use <br /> Compliance forms respond to inquiries about compliance form information provided. <br /> do not require a <br /> password to use. Company Name: Fisher Construction Group,INC. <br /> Instructional and Company Address: 625 Fisher Lane,Burlington,WA 98233 <br /> calculating cells areg <br /> write-protected. Applicant Name: Seth Burwash <br /> Applicant Phone: (360)757-5676 <br /> Applicant Email: sjb@fishercgi.com <br /> (Project Description ❑ New Building ❑✓ Addition ❑Alteration <br /> Occupancy Type <br /> All Commercial 0 Group R-All R1 and R2,R3, R4 over 3 stories <br /> Selection required to enable forms. <br /> Envelope Compliance Path 0 Prescriptive 0 Component Performance <br /> Selection required to enable forms. <br /> Component Performance ® Standard 0 Change of Occupancy/Conditioning 0 <br /> Calculation Type <br /> Selection required to enable ENV-UA ❑Additional Efficiency Package Option-C406.8 Enhanced Envelope <br /> and ENV-SHGC forms. To comply, demonstrate building thermal envelope performance is 15%lower than the Target UA. <br /> ❑ Air barrier testing per Section C402.5.1.2 EAir barrier testing not required <br /> included in project scope <br /> Air Barrier Testing ❑ Additional Efficiency Package Option-C406.9 Reduced Air Infiltration <br /> To comply, demonstrate that measured air leakage of building envelope does not exceed <br /> 0.25 cfm/ft2(air barrier surface area)under test pressure of 0.3 inch w.g. <br /> Vertical Fenestration and Total Vertical Gross Exterior <br /> Skylight Area Calculation Fenestration Above Grade %Vertical <br /> Prescriptive Path-Enter values for (rough opening) divided by Wall Area times 100 equals Fenestration <br /> vertical fenestration, skylights,gross 48 .0 _ 15563.0 X 100 = 0.3% <br /> walls and roof on this ENV-SUM <br /> worksheet. Gross Exterior <br /> Component Performance-Enter values Total Skylight divided by Roof Area times 100 equals %Skylight <br /> in ENV-UA and/or ENV-UA-GROUP-R <br /> worksheet. These values auto-fill from 183.0 — 20158.0 X 100 = 0. 9% <br /> Vertical <br /> Fenestration VERTICAL FENESTRATION AREA COMPLIES <br /> Fenestration Area Area <br /> Compliance <br /> Skylight Area SKYLIGHT AREA COMPLIES <br /> Vertical Fenestration 0 High performance fenestration U-factors and SHGC per C402.4.1.3 <br /> Alternates 0 Dedicated outdoor air system per C402.4.1.4 and C403.6 <br /> Show locations of qualifying daylight zone 0 In buildings>_3 stories,25%or more of NET floor area is in daylight zones per <br /> areas and ft2 on project plans. <br /> 0 In buildings<3 stories,50%or more of CONDITIONED floor area is within daylight zones per <br /> For Daylight Zone Area Calculations- C402.4.1.1 <br /> a)Sidelight areas include primary+ Daylight Zone Calculations <br /> secondary daylght zone areas. Daylight Zone Fenestration Alternate Sidelight Daylight ' Toplight Daylight Percent Daylight <br /> b)Include overlapping toplight and Not Selected. No Calculations Required Zone Area Zone Area Zone Area <br /> sidelight daylight zone areas under <br /> Toplight. <br /> c)Refer to Chapter 2 for net floor area <br /> Spaces in Single Story List all enclosed spaces that exceed 2,500 ft2,have ceiling height greater than 15 ft,and are <br /> Building Requiring Skylights space types required to comply with this provision. <br /> Code requires a minimum of 50%of the floor Space Area(ft2) DLZ Area(ft2) SRR or Aperature Exception <br /> area to be within a skylight daylight zone for <br /> snarifir.snares tvnpc Rnfnr to C402 4 2 for ( - <br />
The URL can be used to link to this page
Your browser does not support the video tag.