Laserfiche WebLink
Vertical Fenestration's. irget Area Adjustment Cap . lations <br /> If vertical fenestration area exceeds maximum allowed per Section C402.4.1,then Target Area Adjustment of all applicable envelope elements is <br /> required. This worksheet automatically calculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information <br /> shown in this worksheet is for reference only and is write-protected.Submit this Target Area Adjustment form with ENV-UA and ENV-SHGC forms. <br /> VF=Vertical fenestration NW=Net above grade wall(excludes fenestration and doors.) <br /> DR=Opaque doors Gross Exterior Above-Grade Wall Area=VF+NW+DR <br /> AG=Above-grade <br /> Proposed Areas <br /> Vertical Fenestration-> VF= 48.0 <br /> Opaque-> NW= 15563.0 DR= 586.0 <br /> Gross Exterior Max Vert.Fen.% Maximum Target <br /> AG Wall Area (C402.3.1) Vert. Fen.Area <br /> 16197.0 X 30.0% — 100 = 4859.1 <br /> Total Vertical Delta Vertical Excess Vertical <br /> Fenestration Maximum Target Fenestration 0 Fenestration <br /> 48.0 — 4859.1 = -4811.1 ? greater = <br /> �> -4811.1 / Multiplier applied to all <br /> Total Vertical Excess Vertical iG Target Vertical Total Vertical Proposed Vertical <br /> _ Target VF Multiplier Fenestration Areas to <br /> Fenestration Fenestration Fenestration Fenestration <br /> calculate Target Vertical <br /> 48.0 — = 48.0 - 48.0 _ 1.00 Fenestration Area <br /> Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Mult. Multiplier applied to all <br /> 15563.0 +. = 15563.0 — 15563.0 = 1.00 Proposed Opaque Above- <br /> Grade Wall Areas to <br /> Tar et Areas - UA calculate Target Above- <br /> Target Grade Wall Area <br /> Commercial <br /> Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> Non-metal frame 48.0 X 1.00 = - <br /> 48.0 <br /> = <br /> Metal frame,fixed X <br /> Metal frame,operable X _ <br /> Metal frame,entrance door X = <br /> Target areas in shaded <br /> Above-grade Wall Proposed Area Target Net Wall Mult. Target Area boxes are applied to <br /> Steel Frame X = target areas on ENV-UA <br /> Metal Building 15563.0 X 1.00 = 15563.0 <br /> Wood/Other frame X = <br /> Mass X = <br /> Mass Transfer Deck X = <br /> Group R Mass X = <br /> Sum of Proposed 15611.0 Sum of Target 15611.0 Sum of target above-grade <br /> wall and vertical <br /> fenestration areas are <br /> Target Areas - SHGC x A calculated to equal the <br /> Non-North Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> PF<0.2 X = <br /> 0.25PF<0.5 X _ <br /> PF>_0.5 X = SHGC target areas in <br /> shaded boxes are applied <br /> North Vertical Fenestration <br /> to target areas on ENV- <br /> PF<0.2 X = SHGC <br /> 0.2<-PF<0.5 X = <br /> PF 0.5 X <br />