Laserfiche WebLink
Interior Lighting - Space-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: AD Systems Warehouse Addition Date 9/5/2017 <br /> Calculation O O Addition- O Addition For Building Department Use <br /> Area NOTE 9 stand alone +existing <br /> O Spaces where<50%of O Spaces where>_50%of O <br /> luminaires are replaced luminaires are replaced <br /> LPA @ Standard O Additional Efficiency Package Option O <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3, the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE 1 <br /> Location(plan#, Ceiling Gross Interior Allowed Watts Allowed <br /> room#) Space Type Height NOTE 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> A2.0, RM 100 Warehouse:Medium/bulky palletized items 25 19433 0.506 9833 <br /> A2.0, RM 101 Workshop 10 1049 1.270 1332 <br /> A2.0, RM 101 Workshop 15 592 1.270 752 <br /> Total Area 21074 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 6 Allowed Watts 11918 <br /> Proposed Lighting Wattage"w" <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description NOTE 4,5,6 Fixtures Fixture NOTE 7 Proposed <br /> RM 100 LED Enclosed and Gasketed,2'3000 Lumen DMW2 LED 34 27 918 <br /> RM 101 High Bay, Dimable LED Fixture,2'12,000 Lumen LED 18 150 2700 <br /> RM 102 High Bay, Dimable LED Fixture,2'12,000 Lumen LED 16 150 2400 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 6018 <br /> Interior Lighting Power Allowance <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope. Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type, lamp type(e.g. T-8), number of lamps in the fixture,and ballast type(if included). For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp, and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they maybe combined with the overall existing building <br /> lighting systems to demonstrate compliance. Refer to C502.1. <br /> b.For alterations and building additions,provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a <br /> building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types <br /> and gross interior areas. <br /> c. If less than 50%of existing lighting fixtures will be replaced,provide total\existing lighting wattage(prior to alteration)in the space provided <br />