My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2201 100TH ST SW AD SYSTEMS 2022-03-07
>
Address Records
>
100TH ST SW
>
2201
>
AD SYSTEMS
>
2201 100TH ST SW AD SYSTEMS 2022-03-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/7/2022 2:19:18 PM
Creation date
3/2/2022 2:15:51 PM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SW
Street Number
2201
Tenant Name
AD SYSTEMS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Fisher Construction Group,Inc. <br /> 1 r�(/, i O Main:360.757.4094 <br /> _ ►l Uv ` Fax:360.757.4005 <br /> FISHER 625 Fisher Lane <br /> Burlington,Washington 98233 <br /> CONSTRUCTION GROUP www.fishercgi.com <br /> October 20, 2017 <br /> Mr.James Bronder, PE <br /> City of Everett Public Works Department <br /> 3200 Cedar St <br /> Everett,WA 98201 <br /> Dear Mr. Bronder, <br /> The following replies are provided in response to plan check comments for the project noted above, dated <br /> October 16, 2017. <br /> General <br /> 1. The building is currently over allowable area (by approximately 20%)for a mixed-occupancy, one-story <br /> building(with mezzanine) as calculated per Section 506.2.2.Alternatively,the building may comply as an <br /> unlimited area building per section 507.5. If that designation is chosen,the required open yards will <br /> need to be shown on the plans. <br /> Comment:As per IBC 507.4, Unlimited Area Building can be used, as the all the side yards are>60'. <br /> Dimensions have been added to 1/A1.1, as well as summary from 2015 IBC stating the ability to use <br /> section 507.4 for an Unlimited Area Building on the Cover Sheet. <br /> 2. The mezzanine was required to have two exit stairs.The current plans for the expansion do not show <br /> the eastern stair that leads into the factory. Please verify that the stairway is currently in place. <br /> Comment:As per IBC 2015 Table 1006.2.1,the mezzanine is only required to have one exit or exit access <br /> doorway if it meets the following criteria with an approved sprinkler system: B occupancy with a <br /> maximum of 49 occupants, 100' maximum common path of egress travel distance. <br /> The existing mezzanine is a B Occupancy of 2,175 SF, resulting in 22 total calculated occupants.That is <br /> below the 49 maximum.The common path of egress from the furthest location on the second story is <br /> 75'total.This is also below the 100' maximum allowance. <br /> As the mezzanine meets the requirements of Table 1006.2.1,only one exit or exit access doorway is <br /> required. <br /> 3. Air barrier testing requirements as specified by Energy Code Section C402.5.1.2 should be noted on the <br /> plans. <br /> Comment:A note has been added referencing Energy Code Section C402.5.1.2 on drawing 1/A2.0. <br /> //2 <br /> Design > Build > Equip > Perform <br />
The URL can be used to link to this page
Your browser does not support the video tag.