Laserfiche WebLink
FORTE • MEMBER REPORT • PASSED <br /> Roof,BM4-Roof:Drop Beam <br /> 1 piece(s)5 1/8"x 16 1/2"24F-V4 DF Glulam <br /> Overall Length:21'1' <br /> 0 0 <br /> � r <br /> r <br /> 20'2" <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> Design Results Actual @ Location Allowed Result LDF Load:Combination(Pattern) System:Roof <br /> Member Reaction(Ibs) 10095 @ 4" 18322(5.50") Passed(55%) -- 1.0 D+1.0 S(All Spans) Member Type:Drop Beam <br /> Building Use:Residential <br /> Shear(Ibs) 8097 @ 1'10" 17180 Passed(47%) 1.15 1.0 D+1.0 S(All Spans) Building Code:IBC 2015 <br /> Pos Moment(Ft-Ibs) 46095 @ 10'4 13/16" 51956 Passed(89%) 1.15 1.0 D+1.0 S(All Spans) Design Methodology:ASD <br /> Live Load Defl.(in) 0.566 @ 10'6 1/2" 1.021 Passed(L/433) -- 1.0 D+1.0 S(All Spans) Member Pitch:0/12 <br /> Total Load Defl.(in) 1.006 @ 10'6" 1.361 Passed(L/244) -- 1.0 D+1.0 S(All Spans) <br /> • Deflection criteria:LL(1/240)and TL(L/180). <br /> •Top Edge Bracing(Lu):Top compression edge must be braced at 21'1"o/c based on loads applied,unless detailed otherwise. <br /> • Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 21'1"o/c based on loads applied,unless detailed otherwise. <br /> •Critical positive moment adjusted by a volume factor of 0.97 that was calculated using length L=20'5". <br /> •The effects of positive or negative camber have not been accounted for when calculating deflection. <br /> •The specified glulam is assumed to have its strong laminations at the bottom of the beam.Install with proper side up as indicated by the manufacturer. <br /> •Applicable calculations are based on NDS. <br /> Bearing Length Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Snow Total Accessories <br /> 1-Column Cap-steel 5.50" 5.50" 3.03" 4824 5271 10095 Blocking <br /> 2-Stud wall-DF 5.50" 5.50" 2.87" 3923 5271 9194 Blocking <br /> •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br /> Dead Snow <br /> Vertical Loads Location(Side) Tributary Width (0.90) (1.15) Comments <br /> 0-Self Weight(PLF) 0 to 21'1" N/A 20.5 -- <br /> 1-Uniform(PSF) 0 to 21'1"(Front) 20' 17.0 25.0 Default Load <br /> 2-Uniform(PLF) 0 to 5'(Front) N/A 229.0 - <br /> Weyerhaeuser Notes <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.Weyerhaeuser expressly disclaims any other warranties <br /> related to the software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is <br /> responsible to assure that this calculation is compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br /> and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser product literature and installation details refer to <br /> www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support information have been provided by BJM <br /> ForteWEB Software Operator Job Notes 5/28/2020 9:59:47 PM UTC <br /> Benjamin].McCann <br /> CT Engineering Inc. ForteWEB v2.4,Engine:V8.0.1.5,Data:V7.3.2.0 <br /> (206) <br /> 285-4512 <br /> bmccann@ctengineering.com Weyerhaeuser File Name:20064-DR Kang RTU <br /> n@cten <br /> Page 5/9 <br />