.l <br /> ( F O R T E • • <br /> MEMBER REPORT PASSED <br /> Main Story,BM5-Floor: Drop Beam <br /> 1 piece(s)5 1/8"x 18"24F-V4 DF Glulam <br /> Overall Length: 14' <br /> 0 0 <br /> 13'1" I, <br /> 0 0 <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> Design Results Actual @ Location Allowed Result LDF Load:Combination(Pattern) System:Floor <br /> Member Reaction(Ibs) 13321 @ 13'8" 18322(5.50") Passed(73%) -- 1.0 D+0.75 L+0.75 S(All Spans) Member Type:Drop Beam <br /> Building Use:Residential <br /> Shear(Ibs) 11221 @ 12'1/2" 18742 Passed(60%) - 1.15 1.0 D+0.75 L+0.75 S(All Spans) Building Code:IBC 2015 <br /> Pos Moment(Ft-Ibs) 56244 @ 8' 63653 Passed(88%) 1.15 1.0 D+0.75 L+0.75 S(All Spans) Design Methodology:ASD <br /> Live Load DeFl.(in) 0.209 @ 7'1 7/16" 0.444 Passed(14766) -- 1.0 D+0.75 L+0.75 S(All Spans) <br /> Total Load DeFl.(in) 0.357 @ 7'1 3/4" 0.667 Passed(L/449) -- 1.0 D+0.75 L+0.75 S(All Spans) <br /> • Deflection criteria:LL(L/360)and TL(L/240). <br /> •Top Edge Bracing(Lu):Top compression edge must be braced at 14'o/c based on loads applied,unless detailed otherwise. <br /> • Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 14'o/c based on loads applied,unless detailed otherwise. <br /> • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L=13'4". <br /> •The effects of positive or negative camber have not been accounted for when calculating deflection. <br /> •The specified glulam is assumed to have its strong laminations at the bottom of the beam.Install with proper side up as indicated by the manufacturer. <br /> •Applicable calculations are based on NDS. <br /> Bearing Length Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Floor Live Snow Total Accessories <br /> 1-Stud wall-of 5.50" 5.50" 3.69" 4483 7000 2763 14246 Blocking <br /> 2-Column Cap-steel 5.50" 5.50" 4.00" 5268 7000 3738 16006 Blocking <br /> •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br /> Dead Floor Live Snow <br /> Vertical Loads Location(Side) Tributary Width (0.90) (1.00) (1.15) Comments <br /> 0-Self Weight(PLF) 0 to 14' N/A 22.4 -- -- <br /> 1-Uniform(PSF) 0 to 14'(Front) 20' 15.0 50.0 - Default Load <br /> Linked from:BM1- <br /> 2-Point(Ib) 8'(Front) N/A 2002 - 2271 Roof:Drop Beam, <br /> Support 1 <br /> Linked from:BM2- <br /> 3-Point(Ib) 8'(Front) N/A 3235 - 4229 Roof:Drop Beam, <br /> Support 1 <br /> Weyerhaeuser Notes <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.Weyerhaeuser expressly disclaims any other warranties <br /> related to the software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is <br /> responsible to assure that this calculation is compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br /> and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser product literature and installation details refer to <br /> www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support information have been provided by BIM <br /> 1 . \Ve) <br /> ForteWEB Software Operator Job Notes 5/28/2020 9:59:47 PM UTC <br /> Benjamin J.McCann <br /> CT Engineering Inc. ForteWEB v2.4, Engine:V8.0.1.5,Data:V7.3.2.0 <br /> (206)285-4512 <br /> bmccann@ctengineering.com Weyerhaeuser File Name:20064-DR Kang RTU <br /> Page 6/9 <br />