Laserfiche WebLink
• • <br /> 4:77- CITY OF EVERETT <br /> Public Works Department <br /> June 18, 2021 <br /> Danielle Fowler <br /> 2812 Architecture <br /> daniel Ie©2812architecture.com <br /> Owner: Shane Kidwell <br /> Job Address: 2817 Wetmore Avenue <br /> Plan Check No: B2106-038 <br /> RE: Building Permit Review Letter <br /> Dear Danielle, <br /> In response to the application for a building permit, the plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. <br /> General <br /> 1. The new door that leads into the stairway vestibule from the street to the basement should <br /> not swing into and over the Right of Way. <br /> 2. A one-hour floor/ceiling assembly (30 minutes per Exception 5) should be provided for <br /> the 2nd floor stair assembly noted on Stair Section 2/A5. IEBC Section 802.2.1 <br /> 3. Exterior exit door 113A need not be a fire-rated assembly. <br /> 4. Exterior window type C within 24" of the doors should be shown as safety glazing. IBC <br /> Section 2406.4 <br /> 5. The handrail extension at the basement level (eastern side of the stairs) will be close to <br /> the door swing and impeding the minimum required landing area. The wall supporting the <br /> extension should continue at least one more tread depth. The handrail should also have <br /> a return. IBC Section 1014.6 <br /> 6. The handrail extensions at the top of the stairs on the second floor should return (D <br /> shape). IBC Section 1014.6 <br /> Accessibility <br /> 1 / <br /> O 3200 Cedar Street © 425.257.8810 O tlee@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov <br />