Laserfiche WebLink
Residcntial Plumbing Scwcr and Drainagc Invcstigation <br /> Sitc Address: <br /> 151 S Colby Ave <br /> 10/l4/13 <br /> Plumbin¢and Drainaec Insucclor: <br /> Steve's Plumbing LLC <br /> 19707 6d'"Ave W,#106 <br /> Lynmvood,WA 9803G <br /> Hause Snecifics: I <br /> • Housc cu�enlly h:is e backwatcr valvc nn sidc scwcr7 NO �i <br /> • House�.- ...anspouts cnnncetcA to side sewer?Yes,4 cnnnected �I <br /> • Does Sidc Sewer have gradc?YES <br /> • Approximatc dcpth of sidc scwcr.at home 4'S"at city 7' , <br /> • Depth and I.ocation of proposed Back���ater Valve: 3' soulh and 2' west of the snuthwest corner I <br /> of thc houac,4'S"decp, <br /> Piumbinc.�^wrr,or i)reinaee Prablems ldentified: I <br /> 1)l louse not�,rotecicd from sewer surcharge. � <br /> Suyycsicd tiolulion: Install hac6�vatcr valvc 3' soulh anA 2' wcst of thc southtvcst corncr nf Ihc housc, <br /> 4'S" deep (see skeich). Vcril'y that �io downspouts cunnccl upstrcam ol' propused backwater vnlve <br /> localion. If downspouts connec� upstream of pmposed hackwater vnlve then they must br.disconnec�ed or � <br /> rcrouted ta conncct�o��•nstreaiu of valve. I <br /> 2)Sidc Scwcr Improvcmaus:thcrc is a do buricd out in yardjust olt garagc as depicicd on GIS j <br /> Su�csted Solution: Raisc to surfacc. ! <br /> � <br /> � <br /> � / <br /> r.'�,7�7 <br />