Laserfiche WebLink
I <br />B I <br />STANDARD ABBREVIATIONS <br />LIST <br />(D) <br />DEMOLISH / DEMOLITION <br />GT <br />GROUT <br />5H <br />SOAP HOLDER <br />(E) <br />EXISTING <br />GWB <br />GYPSUM WALL BOARD <br />SHC <br />SHOWER CURTAIN <br />(F) <br />FUTURE <br />GYP <br />GYPSUM <br />5HT <br />SHEET <br />(R) <br />RELOCATE <br />H.B. <br />HOSE BIB <br />5HTG <br />SHEATHING <br />W <br />REMOVABLE <br />H.C. <br />HANDICAPPED <br />51M <br />SIMILAR <br />(5) <br />SALVAGE <br />H.D. <br />HAND DRYER <br />51 <br />SEISMIC JOINT <br />@ <br />AT <br />HC <br />HOLLOW CORE <br />5LR <br />SEALER <br />A.B. <br />ANCHOR BOLT <br />HDR <br />HEADER <br />SLS <br />SKYLIGHT SYSTEM <br />A.F.F. <br />ABOVE FINISH FLOOR <br />HDW <br />HARDWARE <br />5MU <br />STONE MASONRY UNIT <br />ABB <br />ABBREVIATION <br />HK <br />HOOK <br />SND <br />SANITARY NAPKIN DISPENSER <br />ACM <br />ALUMINUM COMPOSITE MATERIAL <br />HLB <br />HORIZONTAL LOUVER BLINDS <br />5NR <br />SANITARY NAPKIN RECEPTACLE <br />WALL PANEL <br />HM <br />HOLLOW METAL <br />5NTD <br />SANITARY NAPKIN AND TAMPON <br />ACP <br />ARCHITECTURAL CONCRETE <br />HMS <br />HORIZONTAL METAL SIDING <br />DISPENSER <br />PAVER <br />HOR <br />HORIZONTAL <br />SPEC <br />SPECIFICATIONS <br />ACT <br />ACOUSTICAL CEILING TILE <br />HR <br />HOUR <br />SPGL <br />SPANDREL GLASS <br />ADA <br />AMERICANS WITH DIABILITIES ACT <br />HT <br />HEIGHT <br />SPMR <br />SINGLE -PLY MEMBRANE ROOFING <br />ADD'L <br />ADDITIONAL <br />HWD <br />HARDWOOD <br />SQ <br />SQUARE <br />ADJ <br />ADJUSTABLE <br />I.D. <br />IN51DE DIAMETER <br />55 <br />STAINLESS STEEL <br />AESS <br />ARCHITECTURAL EXPOSED <br />IMP <br />INSULATED METAL PANEL <br />55M <br />SOLID SURFACE MATERIAL <br />STRUCTURAL STEEL <br />INT <br />INTERIOR <br />55NR <br />STANDING SEAM METAL ROOFING <br />ALUM <br />ALUMINUM <br />IRGWB <br />IMPACT RESISTANT GYPSUM WALL <br />5T <br />STONE <br />AP <br />ACCORDIAN PARTITION <br />BOARD <br />STD <br />STANDARD <br />APC <br />ARCHITECTURAL POLISHED <br />150 <br />POLYISOCYANURATE RIGID <br />STL <br />STEEL <br />CONCRETE <br />INSULATION <br />5TW <br />STAIN <br />AS <br />ASPHALT SHINGLES <br />JAW <br />JANITOR <br />SV <br />SHEET VINYL <br />ASNB <br />ASSEMBLY <br />JST <br />JOIST <br />T <br />TREAD <br />AWF <br />ACOUSTICAL WALL FABRIC <br />JT <br />JOINT <br />TAG <br />TONGUE AND GROOVE <br />AWP <br />ARCHITECTURAL WALL PANEL <br />LAM <br />LAMINATE <br />T.B. <br />TOWEL BAR <br />B <br />BOLLARD <br />LAV <br />LAVATORY <br />T.I. <br />TENANT IMPROVEMENT <br />B.O.F. <br />BOTTOM OF FOOTING <br />LBR <br />LUMBER <br />T.O. <br />TOP OF <br />BB <br />BACKERBOARD <br />LB5. <br />POUNDS (WEIGHT) <br />T.O.B. <br />TOP OF BEARING <br />BD <br />BOARD <br />LG <br />LAMINATED GLASS <br />T.O.F. <br />TOP OF FLOOR <br />BLDG <br />BUILDING <br />LIN <br />LINOLEUM <br />T.O.W. <br />TOP OF WALL <br />BLDG <br />BLOCKING <br />LP <br />LIGHT POLE <br />T.S.C.D. <br />TOILET SEAT COVER DISPENSER <br />B <br />BEAM <br />LVP <br />LUXURY VINYL PLANK FLOORING <br />TB <br />TACKBOARD <br />BN <br />BIRD NETTING <br />LVR <br />LOUVER <br />TBB <br />TILE BACKERBOARD <br />B <br />BOTTOM <br />LVT <br />LUXURY VINYL TILE <br />TC <br />TOILET COMPARTMENTS <br />BRG <br />BEARING <br />M <br />MORTAR <br />TCP <br />TILT -UP CONCRETE PANEL <br />BRK <br />BRICK MASONRY UNIT <br />N-R <br />MOLD RESISTANT <br />TEMP <br />TEMPORARY <br />BTWN <br />BETWEEN <br />MAS <br />MASONRY <br />TFR <br />TRANSFORMER <br />C <br />COMPACT <br />MAX <br />MAXIMUM <br />THK <br />THICK <br />C.I. <br />CONTINUOUS INSULATION <br />NB <br />NARKERBOARD <br />THML <br />THERMAL <br />C.J. <br />CONTROL JOINT <br />MC <br />MEDICINE CABINET <br />TL <br />TILE <br />C.D.S. <br />CENTER OF STRUCTURE <br />MCP <br />METAL CEILING PANELS <br />TPD <br />TOILET PAPER DISPENSER <br />CAB <br />CABINET <br />NDF <br />MEDIUM DENSITY FIBERBOARD <br />TRTD <br />TREATED <br />CB <br />COVE BASE <br />NECH <br />MECHANICAL <br />TS <br />TUBE STEEL <br />CBB <br />CENENTITIOU5 BACKER BOARD <br />MEP <br />MECHANICAL, ELECTRICAL, <br />TWF <br />TACKABLE WALL FABRIC <br />CER <br />CERAMIC <br />PLUMBING <br />TYP <br />TYPICAL <br />CG <br />CORNER GUARD <br />MES <br />MECHANICAL EQUIPMENT SCREEN <br />U.N.O. <br />UNLESS NOTED OTHERWISE <br />CHRL <br />CHAIR RAIL <br />NF <br />METAL FABRICATIONS <br />UNFIN <br />UNFINISHED <br />CLG <br />CEILING <br />NFR <br />MANUFACTURER <br />VB <br />VAPOR BARRIER <br />CLK <br />CLINKER TILE <br />MIN <br />MINIMUM <br />VCT <br />VINYL COMPOSITION TILE <br />CLR <br />CLEAR <br />MIN. <br />MINUTE <br />VERT <br />VERTICAL <br />CMU <br />CONCRETE MASONRY UNIT <br />MIR <br />MIRROR <br />VMS <br />VERTICAL METAL SIDING <br />COL <br />COLUMN <br />MISC <br />MISCELLANEOUS <br />VP <br />VENEER PLASTER <br />CONC <br />CONCRETE <br />MMV <br />MANUFACTURED MASONRY VENEER <br />W <br />WIDTH <br />CONST <br />CONSTRUCTION <br />MR <br />MOISTURE RESISTANT <br />W.C. <br />WATER CLOSET <br />CONT <br />CONTINUOUS <br />MRP <br />METAL ROOFING PANEL <br />W.W.F. <br />WELDED WIRE FABRIC <br />COLOD <br />COORDINATE <br />MRS <br />METAL RAILING SYSTEM <br />W/ <br />WITH <br />CPT <br />CARPET <br />M5 <br />MANUFACTURED SIDING <br />W/0 <br />WITHOUT <br />CU <br />CUBIC <br />MSP <br />METAL SOFFIT PANEL <br />WAIN <br />WAINSCOT <br />CV <br />COVER <br />M55 <br />METAL STAIR SYSTEM <br />WB <br />W ARD <br />CW5 <br />CURTAIN WALL SYSTEM <br />MTL <br />METAL <br />D <br />DEPTH <br />MV <br />MASONRY VENEER <br />WC <br />COVERING <br />WAALLLL COVERING <br />D.F. <br />DRINKING FOUNTAIN <br />NWP <br />METAL WALL PANEL <br />WD <br />WOOD <br />D.S. <br />DOWNSPOUT <br />N.I.C. <br />NOT IN CONTRACT <br />WF <br />WOOD FLOORING <br />DBL <br />DOUBLE <br />N.T.S. <br />NOT TO SCALE <br />WH <br />WIRE GLASS <br />DFT <br />DRAFTING <br />N/A <br />NOT APPLICABLE <br />WH <br />WATER HEATER <br />DIA <br />DIAMETER <br />NO. <br />NUMBER <br />WIN <br />WINDOW <br />DML <br />DECORATIVE METAL LAMINATE <br />NON <br />NOMINAL <br />WON <br />WALK OFF MAT <br />DN <br />DOWN <br />N5M <br />NATURAL STONE MATERIAL <br />WP <br />WRB <br />WORK POINT <br />WEATHER RESISTIVE BARRIER <br />DR <br />DOOR <br />NT5 <br />NOTES <br />DTL <br />DETAIL <br />WRGWB <br />WATER RESISTANT GYPSUM <br />O.C. <br />ON CENTER <br />WALLBOARD <br />DW <br />DISHWASHER <br />O.D. <br />OUTSIDE DIAMETER <br />WS <br />WOOD SIDING <br />E.F. <br />EXHAUST FAN <br />O.H. <br />OVERHEAD <br />WSEC <br />WASHINGTON STATE ENERGY <br />E.P. <br />ELECTRICAL PANEL <br />O.R.D. <br />OVERFLOW ROOF DRAIN <br />CODE <br />EA <br />EACH <br />O.R.L. <br />OVERFLOW ROOF LEADER <br />WT <br />WEIGHT <br />EF <br />EPDXY FLOORING <br />O.S. <br />OVERFLOW SCUPPER <br />WWS <br />WINDOW WALL SYSTEM <br />EIFS <br />EXTERIOR INSULATION FINISH <br />OPNG <br />OPENING <br />XPS <br />EXTRUDED POLYSTYRENE RIGID <br />SYSTEM <br />OPP <br />OPPOSITE <br />INSULATION <br />EJ <br />EXPANSION JOINT <br />05B <br />ORIENTED STRAND BOARD <br />Y.D. <br />YARD DRAIN <br />EL <br />ELEVATION <br />OZ <br />OUNCE <br />' <br />CENTERLINE <br />ELECT <br />ELECTRICAL <br />P.A.F. <br />POWER ACCUATED FASTNER <br />ELEV <br />ELEVATOR <br />P.T. <br />PRESSURE TREATED <br />ENV <br />ENVELOPE <br />PAC <br />PRECAST ARCHITECTURAL <br />7 <br />EPS <br />EXPANDED POLYSTYRENE RIGID <br />CONCRETE <br />INSULATION <br />PCs <br />PORTLAND CEMENT STUCCO <br />EQ <br />EQUAL <br />PCSU <br />PRECAST CONCRETE SOLID UNIT <br />EQUIP <br />EQUIPMENT <br />PERP <br />PERPENDICULAR <br />EXP <br />EXPANSION <br />PLAN <br />PLASTIC LAMINATE <br />EXT <br />EXTERIOR <br />PLY <br />PLYWOOD <br />F.D. <br />FLOOR DRAIN <br />PP <br />POWER POLE <br />F.E. <br />FIRE EXTINGUISHER <br />PS <br />PROJECTION SCREEN <br />3 <br />o <br />F.H. <br />FIRE HYDRANT <br />PSC <br />PLASTER SKIN COAT OVER <br />m <br />F.I.C. <br />FURNISHED AND INSTALLED BY <br />CONCRETE <br />CONTRACTOR <br />PSF <br />POUND PER SQUARE FOOT <br />o <br />F.I.O. <br />FURNISHED AND INSTALLED BY <br />PSNU <br />PRECAST STONE MASONRY UNIT <br />OWNER <br />Q <br />F.O.I.C. <br />FURNISHED BY OWNER INSTALLED <br />PT <br />PAINT <br />W <br />BY CONTRACTOR <br />PTD <br />PAPER TOWEL DISPENSER <br />an <br />o <br />F.O.S. <br />FACE OF STRUCTURE <br />PTDWR <br />PAPER TOWEL DISPENSER WASTE <br />RECEPTACLE <br />a_ <br />F.P. <br />FLAG POLE <br />' <br />FDN <br />FOUNDATION <br />QTY <br />QUANTITY <br />FF <br />FACTORY FINISH <br />R <br />RADIUS <br />FH <br />FULL HEIGHT <br />R <br />RISER <br />CL <br />FIG <br />FIG <br />R.D. <br />ROOF DRAIN <br />SE <br />R.L. <br />ROOF LEADER <br />o <br />FIN <br />FINI <br />R.O, <br />ROUGH OPENING <br />FLR <br />FLOOR <br />FP <br />FIREPROOFING <br />R.O.W. <br />RIGHT OF WAY <br />3 <br />FRC <br />FIBER REINFORCED CENENTITIOUs <br />RB <br />RUBBER BASE <br />< <br />PANEL <br />RCD <br />ROLLING COUNTER DOOR <br />FRL <br />FIBER REINFORCED LAMINATE <br />REF <br />REFRIGERATOR <br />FRNG <br />FRAMING <br />REINF <br />REINFORCED <br />r <br />FRP <br />FIBER REINFORCED PANEL <br />READ <br />REQUIRED <br />FRSG <br />FIRE RATED SAFETY GLASS <br />RF <br />RUBBER FLOORING <br />> <br />FRT <br />FIRE -RETARDANT TREATED <br />RLT <br />RECITE <br />Q w <br />FT <br />FOOT / FEET <br />RSD <br />ROLLING SERVICE DOOR <br />�o <br />FTG <br />FOOTING <br />RTU <br />ROOF TOP UNIT <br />a Q <br />G.A. <br />GYPSUM ASSOCIATION <br />S <br />SOUND <br />W a <br />G.F.C.I. <br />GOVERNMENT FURNISHED <br />S.D. <br />SOAP DISPENSER <br />0z <br />Ld <br />CONTRACTOR INSTALLED <br />S.O,G. <br />SLAB ON GRADE <br />o <br />G.F.G.I. <br />GOVERNMENT FURNISHED <br />SAE <br />SLIDING AUTOMATIC ENTRANCE <br />GOVERNMENT INSTALLED <br />SC <br />SOLID CORE <br />a <br />GA <br />GAUGE <br />5CH <br />SCHEDULE <br />z <br />GALV <br />GALVANIZED <br />SCR <br />SHOWER CURTAIN ROD <br />GB <br />GRAB BAR <br />SD <br />SECTIONAL DOORS <br />W <br />GC <br />GENERAL CONTRACTOR <br />SDG <br />SIDING <br />a- <br />GEN <br />GENERAL <br />5DT <br />STATIC DISSIPATED TILE <br />10 <br />GFRG <br />GLASS FIBER REINFORCED GYPSUM <br />5F <br />SQUARE FOOT <br />GL <br />GLASS <br />SFS <br />STOREFRONT SYSTEM <br />W <br />GLB <br />GLUE LAMINATE BEAN <br />SG <br />SAFETY GLASS <br />GSF <br />GROSS SQUARE FOOTAGE <br />5G5 <br />SECURITY GRILLE SYSTEM <br />w <br />O � <br />J � <br />a a <br />D _ I F <br />BUILDING EXTERIOR OPENING PROTECTION LEGEND <br />INSTALLATION FOR THE FOLLOWING: <br />WINDOWS (STOREFRONT SYSTEM) <br />STOREFRONT SYSTEM <br />HOLLOW METAL DOORS AND FRAMES <br />LOUVERS <br />INSTALLATION SEQUENCE.- <br />(1) INSTALL MEMBRANE FLASHING AT EACH CORNER OF SILL [I1 [51 <br />(2) INSTALL MEMBRANE FLASHING TO EXTERIOR SHEATHING AND ROUGH OPENING AT SILL [1] [21 <br />(3) INSTALL MEMBRANE FLASHING TO EXTERIOR SHEATHING AND ROUGH OPENING AT JAMB5 [I] [21 <br />(4) INSTALL MEMBRANE FLASHING TO EXTERIOR SHEATHING AND ROUGH OPENING AT HEAD [1] [21 [31 <br />(5) INSTALL SILL METAL FLASHING AT SILL OF ROUGH OPENING. [5) <br />(6) INSTALL HEAD METAL FLASHING AT HEAD OF ROUGH OPENING. [41 [61 <br />(7) INSTALL STOREFRONT SYSTEM SUB -SILL WITH MANUFACTURER's END DAMS. <br />W INSTALL WINDOW FRAME (STOREFRONT SYSTEM, HOLLOW METAL DOOR FRAME OR LOUVER FRAME). <br />(9) INSTALL WEATHER RESISTIVE BARRIER OVER MEMBRANE FLASHING; MINIMUM 6 INCH LAP. [21 <br />I ® CORNER MEMBRANE FLASHING <br />5 ® SILL METAL FLASHING <br />_ 01 <br />FABRICATION OPTIONS <br />SILL METAL FLASHING [51 <br />C <br />FOOTNOTES: <br />EXTEND HEAD METAL FLASHING MINIMUM I -INCH <br />BEYOND EDGE OF FRAME. <br />FORMED HEAD METAL FLASHING. PROVIDE SLIGHT <br />SLOPE TO HORIZONTAL LEG OF FLASHING. * <br />* INSTALL MINIMUM 9 INCH WIDE MEMBRANE <br />FLASHING OVER VERTICAL LEG OF HEAD <br />METAL FLASHING. SEAL WATERTIGHT TO <br />FACE OF WEATHER RESISTIVE BARRIER. <br />HEMMED EDGE <br />PROVIDE SPECIFIED COLOR AND FINISH AT <br />ALL EXPOSED SURFACES [6] <br />INSTALL CONTINUOUS SEALANT BEAD <br />BETWEEN VERTICAL LEG OF SILL METAL <br />FLASHING AND WINDOW FRAME SUB -SILL. <br />INSTALL SEALANT AT FORMED JOINTS. <br />FORMED SILL METAL FLASHING * <br />* EXTEND SILL METAL FLASHING TO <br />INTERIOR SIDE OF FRAME. PROVIDE <br />SLIGHT SLOPE TO BOTTOM PAN; <br />DRAIN TO EXTERIOR SIDE. <br />* INSTALL MINIMUM 9 INCH WIDE MEMBRANE <br />FLASHING OVER VERTICAL LEGS AT <br />JAMBS. SEAL WATERTIGHT TO FACE OF <br />WEATHER RESISTIVE BARRIER OR <br />MEMBRANE FLASHING. <br />HEMMED EDGE <br />PROVIDE SPECIFIED COLOR AND FINISH AT <br />ALL EXPOSED SURFACES [61 <br />[I] CONTRACTOR SHALL INSTALL MEMBRANE FLASHING AT EXTERIOR WALL ROUGH OPENINGS EXTENDING FROM INSIDE <br />FACE OF WALL ROUGH OPENING OVER FACE OF EXTERIOR SHEATHING WITH A MINIMUM COVERAGE OF 9 INCHES <br />COMPLYING WITH ASTM E2112-01. INSTALL MEMBRANE FLASHING WITH WATERTIGHT LAPS AND WITHOUT FISH MOUTHS. <br />FISH MOUTHS MUST BE SLIT, PRESSED FLAT, AND COVERED WITH PATCH OF MEMBRANE THAT EXTENDS BEYOND <br />DAMAGED AREA A MINIMUM OF 6 INCHES. <br />[21 WEATHER RESISTIVE BARRIER MAY BE INSTALLED PRIOR TO INSTALLATION OF MEMBRANE FLASHINGS. CONFIRM <br />COMPATIBILITY AND ADHESION OF MEMBRANE FLASHING TO WEATHER RESISTIVE BARRIER PRIOR TO INSTALLATION. <br />COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS, SPECIFICATIONS AND STANDARD DETAILS FOR <br />INSTALLATION REQUIREMENTS. <br />[31 COORDINATE INSTALLATION SEQUENCE OF METAL FLASHING AT HEAD WITH INSTALLATION OF WINDOW, DOOR OR <br />LOUVER FRAME; BASED ON FRAME TYPE, WALL ASSEMBLY CONSTRUCTION, MATERIALS AND FINISHES. INSTALL IN <br />ACCORDANCE WITH CONTRACT DOCUMENT DETAILS AND APPROVED SHOP DRAWINGS. <br />[41 INSTALL HEAD METAL FLASHING AT ALL EXTERIOR WINDOWS, DOORS AND LOUVERS. METAL FLASHING PROFILE / <br />SHAPE AND DIMENSIONS MAY VARY DEPENDING ON EXTERIOR WALL ASSEMBLY (THICKNESS, MATERIALS AND FINISHES) <br />AND FRAME POSITION WITHIN WALL OPENING. INSTALL IN ACCORDANCE WITH CONTRACT DOCUMENT DETAILS AND <br />APPROVED SHOP DRAWINGS. <br />[51 INSTALL SILL METAL FLASHING AT ALL EXTERIOR WINDOWS AND LOUVERS (EXCEPT NAIL -ON FLANGE TYPE). METAL <br />FLASHING PROFILE / SHAPE AND DIMENSIONS MAY VARY DEPENDING ON EXTERIOR WALL ASSEMBLY (THICKNESS, <br />MATERIALS AND FINISHES) AND FRAME POSITION WITHIN WALL OPENING. INSTALL IN ACCORDANCE WITH CONTRACT <br />DOCUMENT DETAILS AND APPROVED SHOP DRAWINGS. <br />SHEET METAL FLASHING THICKNESS GAUGE <br />GALVANIZED STEEL: MINIMUM 20 GAUGE (0.0359"). LEG "A" IS LESS THAN 2-INCHE5. <br />MINIMUM 18 GAUGE (0.0478"). LEG "A" IS 2-INC14ES TO 4-INCHE5 MAX. <br />ALUMINUM: MINIMUM 18 GAUGE (0.0403"). LEG "A" IS LESS THAN 2-INCHES. <br />MINIMUM 16 GAUGE (0.0508"). LEG "A" 15 2-INCHES TO 4-INCHES MAX. <br />INSTALL SLOPED 5UB-SILL PLATE; A CONTINUOUS SHAPED PRESSURE TREATED WOOD PLATE OR FORMED <br />GALVANIZED SHEET STEEL BREAK SHAPE; SLOPE TOP PLANE OF PLATE TO EXTERIOR SIDE OF ROUGH OPENING. <br />INSTALL SLOPED SUB -SILL PLATE AT SILLS PRIOR TO INSTALLATION OF MEMBRANE FLASHINGS AND SILL METAL <br />FLASHING. <br />INSTALL GENEROUS BED OF SEALANT AT FASTENER LOCATIONS PENETRATING THROUGH SILL METAL FLASHING <br />SLOPED PAN. SEAL WATERTIGHT. <br />INSTALL CLEAR PLASTIC ROUND WEEP TUBES AT 3'-0" MAXIMUM SPACING AND WITHIN 6-INCHES OF JAMBS LOCATED <br />BETWEEN SILL METAL FLASHING AND WINDOW FRAME 5UB-SILL. <br />[61 HEAD METAL FLASHING: ALL VISIBLY EXPOSED SURFACES OF HEAD METAL FLASHING SHALL BE OF COLOR AND FINISH <br />SPECIFIED. CONTRACTOR OPTION TO PROVIDE SINGLE PIECE OR MULTIPLE PIECE HEAD METAL FLASHING BASED ON <br />WALL OPENING INSTALLATION CONDITION AND REQUIREMENTS. <br />D E I F I G � H <br />I <br />M <br />11 <br />1- <br />a <br />ter. <br />HELIX DESIGN GROUP, INC <br />7 ELEVEN <br />BUILDING SHELL <br />75TH STREET SW <br />& HARDESON ROAD <br />EVERETT, WA <br />REVISION DATE <br />9 <br />DATE JOB NO. <br />06.03.20 a 19-026 <br />PERMIT SET <br />1° G035 <br />DRAWING NO. <br />© HELIX DESIGN GROUP, INC.: Al rights reserved. <br />No part of this document may be reproduced in any form or by <br />any means without permission in writing from Helix Design Group <br />