Laserfiche WebLink
I" MP 11 lnT 1 / nATInKl <br />LOCATION MAP <br />SCALE: NTS NORTH <br />non IC!\T I n!\ATInAI <br />�L / AERIAL MAP _ <br />Q" <br />� SCALE: NTS NORTH <br />- ­1 . ­T nr 1117o/1T\ <br />3 BIRD'S EYE VIEW �� <br />SCALE: NTS �°� , , <br />t K. <br />t VAI. <br />d 4 �s <br />" AV �g <br />PROPOSED " <br />t <br />s �x1 w <br />4 SITE PLAN <br />SCALE: NTS NORTH <br />VISIONWORKS #1407 - GREENTREE PLAZA <br />305 SE EVERETT MALL WAY, SUITE 21 <br />EVERETT, WA 98208EVERM ��. �� <br />TENANT COORDINATOR <br />ACF PROPERTY MANAGEMENT, INC. <br />12411 VENURA BOULEVARD <br />STUDIO CITY, CA 91604 <br />TRISTA BROWN <br />tbrown@acfpm.com <br />818-505-6777 ext 212 <br />CODEINDEX <br />EXISTING BUILDING CODE: <br />2018 INTERNATIONAL EXISTING BUILDING CODE <br />BUILDING CODE: <br />2018 INTERNATIONAL BUILDING CODE <br />ACCESSIBILITY: <br />ICC Al17.1-2009 <br />MECHANICAL CODE: <br />2018 INTERNATIONAL MECHANICAL CODE <br />ELECTRICAL CODE: <br />2020 NATIONAL ELECTRICAL CODE <br />PLUMBING CODE: <br />2018 UNIFORM PLUMBING CODE <br />FIRE CODE: <br />2018 INTERNATIONAL FIRE CODE <br />ENERGY CODE: <br />2018 WASHINGTON STATE ENERGY CODE COMMERCIAL <br />BUILDING DATA <br />EXIT 3 <br />WIDTH: 36" <br />CAPACITY: 240 <br />ACTUAL LOAD: 15 <br />EXIT 2 <br />WIDTH: 36" <br />CAPACITY: 240 <br />ACTUAL LOAD: 15 <br />TOTAL LEASED AREA: <br />3,575 SF <br />CONSTRUCTION TYPE: <br />III-B <br />OCCUPANCY CLASS: <br />M - MERCANTILE (PREVIOUS & PROPOSED) <br />EXITS/WIDTH: <br />(1) @ 72" + (2) @ 36" =144" <br />TRAVEL DISTANCE: <br />75 FT (COMMON PATH) / 250 FT TRAVEL - SEE LIFE SAFETY PLAN <br />DEAD END LIMIT: <br />20 FT / 50 FT WITH SPRINKLERS <br />SPRINKLER: <br />EXISTING LAYOUT TO BE REWORKED <br />FIRE ALARM: <br />N/A <br />ALTERATION LEVEL: <br />LEVEL II <br />PREVIOUS TENANT <br />DECOR DEPOT <br />IVE!~ J Fik� . DEi' F. I E4PIE <br />d,APPROVED <br />OAPPROVED,,- TH CHANGESNOTO <br />O REVISE AND REST MIT <br />134MECTED:.r._.. <br />CSWATTACHED!ST/HANW <br />;he issu;3nco r i , .rnlit shall not <br />' rue aull )rity to violate. <br />►side v peov;,, <br />aj Alca°jie <br />issuance of a perrrit n <br />Construrt?r3n docu`nelftI M GOW <br />data shall riot preve! tthe Cillft <br />- <br />Offical from re4eiringthe correction <br />of errors. <br />= <br />l <br />OCCUPANTLOAD <br />FUNCTION OF SPACE (TABLE 1004.5) <br />AREA <br />(GSF) <br />AREA PER. OCC. <br />(GSF) <br />OCC. <br />QTY. <br />Business Areas <br />1513 SF <br />150 <br />11 <br />Mercantile <br />2063 SF <br />60 <br />35 <br />Totals: <br />3575 SF <br />1 <br />46 <br />Building Area Legend <br />r V1�T1..i'a rVIT A TI"1A\lrl nl(\TAAI/'.r, n71 <br />5 L-11 L_ V%11 L il I I I L—rl I-A1O11\7 [l". I\LI "IN I V LIVI Ii 1#1 1 11 \JIY VI 1L 1 <br />SCALE: 3/32" = T-0" W <br />1Vw1I r <br />H DEMISING WALL E-102.00 FOR EMERGENCY LIGHTING <br />IN <br />EXIT 1 <br />WIDTH: 72" <br />CAPACITY: 480 <br />ACTUAL LOAD: 16 <br />The issuance of a permit shall not <br />be Constryued as authority to violate, <br />cancel or setae any provision of <br />the gverett. ire Code or other <br />applicaW regulations or taws. The <br />issuance of a permit based on <br />coveUueborI documents and other <br />data "I not prevent the Fire Code <br />011110811 from requiring the correction <br />of error's. <br />A difi n i Permits Are Required <br />6,,)r This Project T6Include, <br />I u robin Sprinkler <br />a <br />Permit#: B2109-028 <br />Site Address: 305 SE EVERETT MALL WAY <br />Owner: GREENTREE PLAZA 18 B LLC <br />Tenant: [TenNamel <br />App. Date: 9/9/2021 <br />Proposed Use: COMMERCIAL ALTERATIONS <br />Description: EMPTY SPACE TO BE OUTFIT FOR VISION <br />ORKS RETAIL STORE <br />Reviewed Date: <br />XI—Cffice Set lab Site Set Fire/ Ilan Set <br />APPROVED <br />Office of Community, Planning & Economic Davelopmerlit <br />PLANNI TMENT <br />E:,E. <br />DRAWING INDEX <br />GENERAL <br />G-101.00 <br />COVER SHEET <br />G-102.00 <br />GENERAL NOTES & DETAILS <br />G-103.00 <br />SPECIFICATIONS <br />ARCHITECTURAL <br />A-101.00 <br />DEMO & FLOOR PLANS & NOTES <br />A-102.00 <br />RCP & FURNITURE & EQUIPMENT PLANS & NOTES <br />A-103.00 <br />FINISHES PLAN & NOTES <br />A-104.00 <br />INTERIOR ELEVATIONS & DETAILS <br />MECHANICAL <br />M-101.00 <br />MECHANICAL PLANS, NOTES & SCHEDULES <br />ELECTRICAL <br />E-101.00 <br />POWER PLAN & DETAILS <br />E-102.00 <br />LIGHTING & COMMUNICATION PLANS & DETAILS <br />E-103.00 <br />POWER & DATA ELEVATIONS <br />PLUMBING <br />P-101.00 <br />PLUMBING PLANS <br />P-102.00 <br />PLUMBING SPECS & DETAILS <br />RESPONSIBILITY SCHEDULE <br />RESPONSIBILITY SCHEDULE <br />V = VISIONWOr KS, L = LANDLORD, G = GENERAL CONTRACTOR, 0 = OTHER, E = EXISTING <br />FURNISHED BY INSTALLED BY <br />ITEM - JV I LI G I 0 V L G 0 E REMARKS <br />MECHANICAL <br />RTU S <br />V = VISIONWORKS, L = LANDLORD, G = GENERAL CONTRACTOR, 0 = OTHER, E = EXISTING _ <br />ITEM <br />FURNISHED BY <br />INSTALLED BY <br />E <br />REMARKS <br />VPI WILL APPLY AND GC WILL PICK UP <br />V L G 0 <br />V L G 0 <br />GENERAL <br />BUILDING PERMIT <br />PERMIT APPLICATION FEES <br />• <br />UNLESS NOTED OTHERWISE <br />RTU CURB(S) <br />10 <br />® <br />PROVIDE CURB ADAPTERS <br />PERMIT FEES <br />® <br />UNLESS NOTED OTHERWISE <br />DUCT DISTRIBUTION <br />TRADE PERMITS <br />® <br />ALL SUBS TO OBTAIN THEIR PERMITS <br />SUPPLY & RETURN DIFFUSERS <br />SIGNAGE <br />• <br />® <br />VPI VENDOR <br />THERMOSTATS <br />0 <br />0 <br />EXTERIOR GRAPHICS <br />® <br />® <br />VPI VENDOR <br />RTU PLACEMENT <br />TINT - WEST/EAST FACING <br />H® <br />. <br />VPI VENDOR <br />ROOF PENETRATION OPEN & PATCH <br />_ <br />® <br />GC TO UTILIZE LANDLORD'S ROOFER <br />ITEM <br />FURNISHED BY <br />INSTALLED BYL <br />E <br />REMARKS <br />RESTROOM EXHAUST FAN SYSTEM <br />- <br />V G 0 <br />V L G 0 <br />ITEM <br />FURNISHED BY <br />INSTALLED BY <br />E <br />-- <br />REMARKS <br />ARCHITECTURAL <br />V L G 0 <br />V L G 0 <br />SUB -FLOORING CONCRETE FILL IN <br />• <br />® <br />ELECTRICAL <br />INTERIOR PARTITIONS <br />® <br />® <br />UNLESS OTHERWISE NOTED <br />SERVICE TO PREMISES <br />RESTROOM PARTITIONS <br />® <br />! <br />MAIN PANEL W/ BREAKERS <br />INSULATION <br />® <br />® <br />FIRST SUB PANEL W/ BREAKERS <br />• <br />ENTRANCE DOORS &HARDWARE <br />• <br />BEST CORE REQ'D - SEE BELOW <br />TRANSFORMER _ <br />NOT APPLICABLE <br />REAR EXIT DOOR & HARDWARE <br />• <br />GC TO VERIFY MEETS VPI STANDARD <br />LIGHTING <br />_ <br />®_ <br />INTERIOR DOORS & HARDWARE <br />• <br />® <br />LIGHTING CONTACTOR <br />RESTROOM DOORS & HARDWARE <br />® <br />® <br />SWITCHES & DIMMERS <br />BEST COMPATIBLE CYLINDERS <br />® <br />• <br />CONST. CORE BY GC. PERM CORE BY VPI <br />ELECTRICAL OUTLETS IN WALLS <br />VISIONWORKS LOGO MAT <br />NA <br />ELECTRICAL OUTLETS IN FIXTURES <br />ELECT SUB TO CONNECT TO JUNCTION BOXES <br />ALUMINUM STOREFRONT GLAZING <br />® <br />EXTERIOR SIGNAGE J-BOX <br />® <br />• <br />EXISTING MAY BE PRESENT <br />LAY -IN CEILING & GRID <br />® <br />_ <br />® <br />ELECT J-BOX IN FLOOR STUB -UP <br />• <br />GYP CEILING <br />® <br />® <br />FIRE ALARM SYSTEM <br />NA <br />LVT <br />® <br />® <br />GC TO COORDINATE W/ VPI <br />SMOKE DETECTOR SYSTEM <br />NA <br />LVT GLUE <br />NA <br />BURGLAR ALARM SYSTEM _ <br />_ <br />GC TO COORDINATE W/ VPI VENDOR <br />LVT TRANSITION <br />NA <br />CARBON MONOXIDE DETECTOR SYSTEM <br />• <br />BASE <br />• <br />® <br />ITEM <br />FURNISHED BY <br />INSTALLED BY <br />REMARKS <br />PAINT <br />® <br />® <br />V L G O <br />V L <br />FRP <br />NA <br />PLUMBING <br />RESTROOM MIRROR <br />® <br />e <br />RESTROOM FIXTURES <br />® <br />® <br />INSTALL PER ADA <br />TOILET PAPER DISPENSER <br />A <br />® <br />_ <br />WATER FOUNTAINS _ _ <br />® <br />® <br />PAPER TOWEL DISPENSER <br />® <br />GC TO PROVIDED DISPENSER IN RR ONLY <br />CONTACT LENS SINK <br />_ <br />HAND SOAP DISPENSER <br />® <br />REFRACTING ROOM SINK <br />• <br />HAND SANITIZER DISPENSER <br />® <br />® <br />SERVICE SINK <br />A <br />TOILET SEAT COVER DISPENSER <br />• <br />FLOOR DRAINS <br />__ <br />NOT APPLICABLE <br />RESTROOM GRAB BARS <br />• <br />®_ <br />PROVIDE GRAB BARS PER ADA <br />WATER HEATER _ <br />. <br />•_ <br />SANITARY NAPKIN DISPOSAL <br />• <br />® <br />FIRE SPRINKLERS <br />• <br />LICENSED CONTRACTOR TO DESIGN & PERMIT <br />UTILITY HOOK <br />10 <br />10 <br />ITEM <br />FURNISHED BY <br />INSTALLED BY <br />E <br />REMARKS <br />TACTILE SIGNS <br />® <br />V L G 01 <br />V L G 0 <br />INTERIOR STORE SIGNAGE & PICTURES <br />® <br />10 <br />_ VOICE & DATA <br />MERCHANDISE SIGNAGE <br />0 <br />• <br />SERVICE TO PREMISES <br />FIXTURES <br />i <br />• <br />TELEPHONE BOARD <br />_ <br />® <br />GC TO MAKE ADJUSTMENTS AS NEEDED <br />FURNITURE <br />• <br />• <br />CAT 6 PULLS <br />®® <br />® <br />MARK BOTH ENDS OF PULLS ACCORDINGLY <br />SHELVING <br />• <br />0 <br />CAT 6 TERMINATIONS <br />• <br />_ <br />® <br />VPI'S VENDOR TO TERMINATE AND CERTIFY <br />CHAIR RAIL/CORNER GUARDS <br />e <br />• <br />IT RACK _ <br />• <br />® <br />VPI'S VENDOR TO INSTALL <br />WALL MIRRORS <br />A <br />• <br />POS SYSTEM <br />DR'S EQUIPMENT <br />0 <br />TELEPHONE SYSTEM <br />1 VPI'S VENDOR TO INSTALL <br />LOCKERS <br />CONDUIT FROM LL DEMARK TO SPACE_ <br />COAT RACK <br />SERVICE FROM DEMARK TO SPACE <br />BULLETIN BOARDS <br />0 <br />ROKU TV & TV MOUNT <br />_ <br />STOOLS - PRETEST & EXAM LOCATIONS <br />0® <br />_ <br />4'X4' PLEXI GLASS IN REFRACTING RMS <br />VPI VENDORS <br />SIGNAGE <br />SELINA SCHMIDTKE PRESTIGE <br />SIGN GROUP, INC. <br />210.291.0668 <br />selina@prestigesigngroup.com <br />EXTERIOR GRAPHICSITINT <br />GRAY BALOG <br />STERLING DPFI <br />248.302.2564 <br />gray.b@stedingdpfi.com <br />BARRICADE GRAPHICS <br />CARLA DIBENEDETTO <br />BOSTON BARRICADE COMPANY <br />561.255.8142 <br />cdibenedetto@bostonbarricade.com <br />S C H EI D <br />CONTACT <br />0.716.884.0059 <br />F. 716.884.6414 <br />SCHEIDAIA.COM <br />® ISSUE DATE DESCRIPTION <br />08/27/2021 CHECK SET <br />09/01/2021 PERMIT SET <br />SEALISIGNATURE <br />,� � : I Ill t lll, 111 l 111 11 l <br />This drawing is copyrighted under the United States Copy Right Law and is the property <br />of Scheid Architectural, the use of this drawing in any form without written permission is <br />strictly prohibited. <br />SHEET TITLE <br />COVER SHEET <br />�T °VEREi � <br />REVIEWED R P RI I <br />PROJECT NUMBER <br />2021-067 <br />PLOT DATE @ <br />9/1/2021 3:50:46 PM,e.. <br />SHEET <br />G-101.00 <br />