My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
305 SE EVERETT MALL WAY 2021 VISION WORKS Plans 2022-11-14
>
Address Records
>
SE EVERETT MALL WAY
>
305
>
VISION WORKS
>
Plans
>
305 SE EVERETT MALL WAY 2021 VISION WORKS Plans 2022-11-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2022 9:43:07 AM
Creation date
4/18/2022 11:25:56 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
305
Tenant Name
VISION WORKS
Permit
B2109-028
Year
2021
Notes
EMPTY SPACE TO BE OUFIT FOR VISION WORKS RETAIL STORE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I" MP 11 lnT 1 / nATInKl <br />LOCATION MAP <br />SCALE: NTS NORTH <br />non IC!\T I n!\ATInAI <br />�L / AERIAL MAP _ <br />Q" <br />� SCALE: NTS NORTH <br />- 1 . T nr 1117o/1T\ <br />3 BIRD'S EYE VIEW �� <br />SCALE: NTS �°� , , <br />t K. <br />t VAI. <br />d 4 �s <br />" AV �g <br />PROPOSED " <br />t <br />s �x1 w <br />4 SITE PLAN <br />SCALE: NTS NORTH <br />VISIONWORKS #1407 - GREENTREE PLAZA <br />305 SE EVERETT MALL WAY, SUITE 21 <br />EVERETT, WA 98208EVERM ��. �� <br />TENANT COORDINATOR <br />ACF PROPERTY MANAGEMENT, INC. <br />12411 VENURA BOULEVARD <br />STUDIO CITY, CA 91604 <br />TRISTA BROWN <br />tbrown@acfpm.com <br />818-505-6777 ext 212 <br />CODEINDEX <br />EXISTING BUILDING CODE: <br />2018 INTERNATIONAL EXISTING BUILDING CODE <br />BUILDING CODE: <br />2018 INTERNATIONAL BUILDING CODE <br />ACCESSIBILITY: <br />ICC Al17.1-2009 <br />MECHANICAL CODE: <br />2018 INTERNATIONAL MECHANICAL CODE <br />ELECTRICAL CODE: <br />2020 NATIONAL ELECTRICAL CODE <br />PLUMBING CODE: <br />2018 UNIFORM PLUMBING CODE <br />FIRE CODE: <br />2018 INTERNATIONAL FIRE CODE <br />ENERGY CODE: <br />2018 WASHINGTON STATE ENERGY CODE COMMERCIAL <br />BUILDING DATA <br />EXIT 3 <br />WIDTH: 36" <br />CAPACITY: 240 <br />ACTUAL LOAD: 15 <br />EXIT 2 <br />WIDTH: 36" <br />CAPACITY: 240 <br />ACTUAL LOAD: 15 <br />TOTAL LEASED AREA: <br />3,575 SF <br />CONSTRUCTION TYPE: <br />III-B <br />OCCUPANCY CLASS: <br />M - MERCANTILE (PREVIOUS & PROPOSED) <br />EXITS/WIDTH: <br />(1) @ 72" + (2) @ 36" =144" <br />TRAVEL DISTANCE: <br />75 FT (COMMON PATH) / 250 FT TRAVEL - SEE LIFE SAFETY PLAN <br />DEAD END LIMIT: <br />20 FT / 50 FT WITH SPRINKLERS <br />SPRINKLER: <br />EXISTING LAYOUT TO BE REWORKED <br />FIRE ALARM: <br />N/A <br />ALTERATION LEVEL: <br />LEVEL II <br />PREVIOUS TENANT <br />DECOR DEPOT <br />IVE!~ J Fik� . DEi' F. I E4PIE <br />d,APPROVED <br />OAPPROVED,,- TH CHANGESNOTO <br />O REVISE AND REST MIT <br />134MECTED:.r._.. <br />CSWATTACHED!ST/HANW <br />;he issu;3nco r i , .rnlit shall not <br />' rue aull )rity to violate. <br />►side v peov;,, <br />aj Alca°jie <br />issuance of a perrrit n <br />Construrt?r3n docu`nelftI M GOW <br />data shall riot preve! tthe Cillft <br />- <br />Offical from re4eiringthe correction <br />of errors. <br />= <br />l <br />OCCUPANTLOAD <br />FUNCTION OF SPACE (TABLE 1004.5) <br />AREA <br />(GSF) <br />AREA PER. OCC. <br />(GSF) <br />OCC. <br />QTY. <br />Business Areas <br />1513 SF <br />150 <br />11 <br />Mercantile <br />2063 SF <br />60 <br />35 <br />Totals: <br />3575 SF <br />1 <br />46 <br />Building Area Legend <br />r V1�T1..i'a rVIT A TI"1A\lrl nl(\TAAI/'.r, n71 <br />5 L-11 L_ V%11 L il I I I L—rl I-A1O11\7 [l". I\LI "IN I V LIVI Ii 1#1 1 11 \JIY VI 1L 1 <br />SCALE: 3/32" = T-0" W <br />1Vw1I r <br />H DEMISING WALL E-102.00 FOR EMERGENCY LIGHTING <br />IN <br />EXIT 1 <br />WIDTH: 72" <br />CAPACITY: 480 <br />ACTUAL LOAD: 16 <br />The issuance of a permit shall not <br />be Constryued as authority to violate, <br />cancel or setae any provision of <br />the gverett. ire Code or other <br />applicaW regulations or taws. The <br />issuance of a permit based on <br />coveUueborI documents and other <br />data "I not prevent the Fire Code <br />011110811 from requiring the correction <br />of error's. <br />A difi n i Permits Are Required <br />6,,)r This Project T6Include, <br />I u robin Sprinkler <br />a <br />Permit#: B2109-028 <br />Site Address: 305 SE EVERETT MALL WAY <br />Owner: GREENTREE PLAZA 18 B LLC <br />Tenant: [TenNamel <br />App. Date: 9/9/2021 <br />Proposed Use: COMMERCIAL ALTERATIONS <br />Description: EMPTY SPACE TO BE OUTFIT FOR VISION <br />ORKS RETAIL STORE <br />Reviewed Date: <br />XI—Cffice Set lab Site Set Fire/ Ilan Set <br />APPROVED <br />Office of Community, Planning & Economic Davelopmerlit <br />PLANNI TMENT <br />E:,E. <br />DRAWING INDEX <br />GENERAL <br />G-101.00 <br />COVER SHEET <br />G-102.00 <br />GENERAL NOTES & DETAILS <br />G-103.00 <br />SPECIFICATIONS <br />ARCHITECTURAL <br />A-101.00 <br />DEMO & FLOOR PLANS & NOTES <br />A-102.00 <br />RCP & FURNITURE & EQUIPMENT PLANS & NOTES <br />A-103.00 <br />FINISHES PLAN & NOTES <br />A-104.00 <br />INTERIOR ELEVATIONS & DETAILS <br />MECHANICAL <br />M-101.00 <br />MECHANICAL PLANS, NOTES & SCHEDULES <br />ELECTRICAL <br />E-101.00 <br />POWER PLAN & DETAILS <br />E-102.00 <br />LIGHTING & COMMUNICATION PLANS & DETAILS <br />E-103.00 <br />POWER & DATA ELEVATIONS <br />PLUMBING <br />P-101.00 <br />PLUMBING PLANS <br />P-102.00 <br />PLUMBING SPECS & DETAILS <br />RESPONSIBILITY SCHEDULE <br />RESPONSIBILITY SCHEDULE <br />V = VISIONWOr KS, L = LANDLORD, G = GENERAL CONTRACTOR, 0 = OTHER, E = EXISTING <br />FURNISHED BY INSTALLED BY <br />ITEM - JV I LI G I 0 V L G 0 E REMARKS <br />MECHANICAL <br />RTU S <br />V = VISIONWORKS, L = LANDLORD, G = GENERAL CONTRACTOR, 0 = OTHER, E = EXISTING _ <br />ITEM <br />FURNISHED BY <br />INSTALLED BY <br />E <br />REMARKS <br />VPI WILL APPLY AND GC WILL PICK UP <br />V L G 0 <br />V L G 0 <br />GENERAL <br />BUILDING PERMIT <br />PERMIT APPLICATION FEES <br />• <br />UNLESS NOTED OTHERWISE <br />RTU CURB(S) <br />10 <br />® <br />PROVIDE CURB ADAPTERS <br />PERMIT FEES <br />® <br />UNLESS NOTED OTHERWISE <br />DUCT DISTRIBUTION <br />TRADE PERMITS <br />® <br />ALL SUBS TO OBTAIN THEIR PERMITS <br />SUPPLY & RETURN DIFFUSERS <br />SIGNAGE <br />• <br />® <br />VPI VENDOR <br />THERMOSTATS <br />0 <br />0 <br />EXTERIOR GRAPHICS <br />® <br />® <br />VPI VENDOR <br />RTU PLACEMENT <br />TINT - WEST/EAST FACING <br />H® <br />. <br />VPI VENDOR <br />ROOF PENETRATION OPEN & PATCH <br />_ <br />® <br />GC TO UTILIZE LANDLORD'S ROOFER <br />ITEM <br />FURNISHED BY <br />INSTALLED BYL <br />E <br />REMARKS <br />RESTROOM EXHAUST FAN SYSTEM <br />- <br />V G 0 <br />V L G 0 <br />ITEM <br />FURNISHED BY <br />INSTALLED BY <br />E <br />-- <br />REMARKS <br />ARCHITECTURAL <br />V L G 0 <br />V L G 0 <br />SUB -FLOORING CONCRETE FILL IN <br />• <br />® <br />ELECTRICAL <br />INTERIOR PARTITIONS <br />® <br />® <br />UNLESS OTHERWISE NOTED <br />SERVICE TO PREMISES <br />RESTROOM PARTITIONS <br />® <br />! <br />MAIN PANEL W/ BREAKERS <br />INSULATION <br />® <br />® <br />FIRST SUB PANEL W/ BREAKERS <br />• <br />ENTRANCE DOORS &HARDWARE <br />• <br />BEST CORE REQ'D - SEE BELOW <br />TRANSFORMER _ <br />NOT APPLICABLE <br />REAR EXIT DOOR & HARDWARE <br />• <br />GC TO VERIFY MEETS VPI STANDARD <br />LIGHTING <br />_ <br />®_ <br />INTERIOR DOORS & HARDWARE <br />• <br />® <br />LIGHTING CONTACTOR <br />RESTROOM DOORS & HARDWARE <br />® <br />® <br />SWITCHES & DIMMERS <br />BEST COMPATIBLE CYLINDERS <br />® <br />• <br />CONST. CORE BY GC. PERM CORE BY VPI <br />ELECTRICAL OUTLETS IN WALLS <br />VISIONWORKS LOGO MAT <br />NA <br />ELECTRICAL OUTLETS IN FIXTURES <br />ELECT SUB TO CONNECT TO JUNCTION BOXES <br />ALUMINUM STOREFRONT GLAZING <br />® <br />EXTERIOR SIGNAGE J-BOX <br />® <br />• <br />EXISTING MAY BE PRESENT <br />LAY -IN CEILING & GRID <br />® <br />_ <br />® <br />ELECT J-BOX IN FLOOR STUB -UP <br />• <br />GYP CEILING <br />® <br />® <br />FIRE ALARM SYSTEM <br />NA <br />LVT <br />® <br />® <br />GC TO COORDINATE W/ VPI <br />SMOKE DETECTOR SYSTEM <br />NA <br />LVT GLUE <br />NA <br />BURGLAR ALARM SYSTEM _ <br />_ <br />GC TO COORDINATE W/ VPI VENDOR <br />LVT TRANSITION <br />NA <br />CARBON MONOXIDE DETECTOR SYSTEM <br />• <br />BASE <br />• <br />® <br />ITEM <br />FURNISHED BY <br />INSTALLED BY <br />REMARKS <br />PAINT <br />® <br />® <br />V L G O <br />V L <br />FRP <br />NA <br />PLUMBING <br />RESTROOM MIRROR <br />® <br />e <br />RESTROOM FIXTURES <br />® <br />® <br />INSTALL PER ADA <br />TOILET PAPER DISPENSER <br />A <br />® <br />_ <br />WATER FOUNTAINS _ _ <br />® <br />® <br />PAPER TOWEL DISPENSER <br />® <br />GC TO PROVIDED DISPENSER IN RR ONLY <br />CONTACT LENS SINK <br />_ <br />HAND SOAP DISPENSER <br />® <br />REFRACTING ROOM SINK <br />• <br />HAND SANITIZER DISPENSER <br />® <br />® <br />SERVICE SINK <br />A <br />TOILET SEAT COVER DISPENSER <br />• <br />FLOOR DRAINS <br />__ <br />NOT APPLICABLE <br />RESTROOM GRAB BARS <br />• <br />®_ <br />PROVIDE GRAB BARS PER ADA <br />WATER HEATER _ <br />. <br />•_ <br />SANITARY NAPKIN DISPOSAL <br />• <br />® <br />FIRE SPRINKLERS <br />• <br />LICENSED CONTRACTOR TO DESIGN & PERMIT <br />UTILITY HOOK <br />10 <br />10 <br />ITEM <br />FURNISHED BY <br />INSTALLED BY <br />E <br />REMARKS <br />TACTILE SIGNS <br />® <br />V L G 01 <br />V L G 0 <br />INTERIOR STORE SIGNAGE & PICTURES <br />® <br />10 <br />_ VOICE & DATA <br />MERCHANDISE SIGNAGE <br />0 <br />• <br />SERVICE TO PREMISES <br />FIXTURES <br />i <br />• <br />TELEPHONE BOARD <br />_ <br />® <br />GC TO MAKE ADJUSTMENTS AS NEEDED <br />FURNITURE <br />• <br />• <br />CAT 6 PULLS <br />®® <br />® <br />MARK BOTH ENDS OF PULLS ACCORDINGLY <br />SHELVING <br />• <br />0 <br />CAT 6 TERMINATIONS <br />• <br />_ <br />® <br />VPI'S VENDOR TO TERMINATE AND CERTIFY <br />CHAIR RAIL/CORNER GUARDS <br />e <br />• <br />IT RACK _ <br />• <br />® <br />VPI'S VENDOR TO INSTALL <br />WALL MIRRORS <br />A <br />• <br />POS SYSTEM <br />DR'S EQUIPMENT <br />0 <br />TELEPHONE SYSTEM <br />1 VPI'S VENDOR TO INSTALL <br />LOCKERS <br />CONDUIT FROM LL DEMARK TO SPACE_ <br />COAT RACK <br />SERVICE FROM DEMARK TO SPACE <br />BULLETIN BOARDS <br />0 <br />ROKU TV & TV MOUNT <br />_ <br />STOOLS - PRETEST & EXAM LOCATIONS <br />0® <br />_ <br />4'X4' PLEXI GLASS IN REFRACTING RMS <br />VPI VENDORS <br />SIGNAGE <br />SELINA SCHMIDTKE PRESTIGE <br />SIGN GROUP, INC. <br />210.291.0668 <br />selina@prestigesigngroup.com <br />EXTERIOR GRAPHICSITINT <br />GRAY BALOG <br />STERLING DPFI <br />248.302.2564 <br />gray.b@stedingdpfi.com <br />BARRICADE GRAPHICS <br />CARLA DIBENEDETTO <br />BOSTON BARRICADE COMPANY <br />561.255.8142 <br />cdibenedetto@bostonbarricade.com <br />S C H EI D <br />CONTACT <br />0.716.884.0059 <br />F. 716.884.6414 <br />SCHEIDAIA.COM <br />® ISSUE DATE DESCRIPTION <br />08/27/2021 CHECK SET <br />09/01/2021 PERMIT SET <br />SEALISIGNATURE <br />,� � : I Ill t lll, 111 l 111 11 l <br />This drawing is copyrighted under the United States Copy Right Law and is the property <br />of Scheid Architectural, the use of this drawing in any form without written permission is <br />strictly prohibited. <br />SHEET TITLE <br />COVER SHEET <br />�T °VEREi � <br />REVIEWED R P RI I <br />PROJECT NUMBER <br />2021-067 <br />PLOT DATE @ <br />9/1/2021 3:50:46 PM,e.. <br />SHEET <br />G-101.00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.