Laserfiche WebLink
• . lY.i • � ! <br />. I• I it r i I �� '� I� l <br />•,- <br />- <br />w I w i �, Y • ,� I <br />• ! i • <br />t <br />l • � a '' I i <br />Y R 1 i` -+ - y 1 • <br />• • # � Y <br />• i- <br />GENERAL NOTES <br />f i ! Y >• i I i i <br />i- <br />r <br />• i Y ! :,• � � r r• i • <br />! I iI •: I I ! i i i! <br />- r Y • <br />• I • <br />r Yriss- Y A Y,.. <br />I•, Yr • . ws. • Y' • • <br />i <br />i I• Y- w.. I� I <br />4 I I i <br />• <br />l _ ii• � • . <br />'- Y! i i t Y . i • i iw i <br />�; �r_ �i�r r • <br />` • ! ; ,i ! Y • Y <br />i • t <br />� wr i ! • i •` <br />• •w • •� � � Y i •-•Y <br />* '� ` F Ilk i Y - 1 ' 3 •:.. - : :1Y'.. <br />GENERALSTRUCTI NOTES <br />1, ALL STUDS, CEILING FURRING, AND FRAMING MEMBERS SHALL BE PLACED SO AS TO <br />AVOID INTERFERENCE WITH CASEWORK, RECESSED LIGHTING FIXTURES, PIPING, <br />DUCTWORK, ETC,. <br />2. THE TENANT'S WRITTEN AUTHORIZATION IS REQUIRED BEFORE ANY WORK INVOLVING <br />ADDITIONAL COST IS PERFORMED. <br />3. G.C. WILL CLEAN THE INSIDE OF ALL WINDOWS PRIOR TO THE INSTALLATION OF WINDOW <br />TREATMENTS. G.C. WILL REMOVE ALL EXISTING WINDOW TREATMENTS PRIOR TO <br />BEGINNING OF CONSTRUCTION AND STORE THEM FOR THEIR REUSE. <br />4. ALL MISCELLANEOUS NAILS, HANGERS, AND STAPLES; OLD WIRES AND <br />CONDUITS, MISCELLANEOUS ELECTRICAL AND TELEPHONE EQUIPMENT WILL BE REMOVED <br />FROM ANY AREAS EXPOSED TO NEW WORK, <br />5. ALL CEILING TILE WILL BE INSTALLED WITH PATTERN RUNNING IN SAME DIRECTION <br />6. ALL SWITCHES AND RECEPTACLES BE INSTALLED AT HEIGHTS AS PER TAS 205.1 AND 309. <br />7. HVAC IS TO BE TESTED AND BALANCED. <br />8. CEILING AND ELECTRICAL CONTRACTORS ARE NOT TO DISTURB FIREPROOFING WHEN <br />INSTALLING FIXTURES. <br />9. GENERAL CONTRACTOR SHALL HAVE THE RESPONSIBILITY TO MEET THE BUILDING <br />INSPECTOR AT THE JOB SITE FOR APPROVALS. <br />10. GENERAL CONTRACTOR WILL REMOVE EXISTING HARD SURFACE FLOORING. IN THE CASE <br />OF V,A.T., CM IS TO BE NOTIFIED. <br />11, ALL DIMENSIONS WILL BE FIELD VERIFIED BY INDIVIDUAL CONTRACTORS. <br />12. CM WILL BE FINAL JUDGE OF THE QUALITY OF FINISHES. <br />13, ALL EXPOSED PLASTIC LAMINATE SURFACES WILL BE FREE OF DENTS, TOOL MARKS, <br />WARPAGE, GLUE AND OPEN JOINTS. ALL CORNER JOINTS WILL BE ADDED IF NECESSARY <br />EVEN IF NOT CALLED FOR ON PLANS. GLUING SHALL BE HOTPLATE METHOD WHERE <br />POSSIBLE. ALL MATERIAL GRAINS ON DIFFERENT PLANES SHALL BE MATCHED WHERE <br />POSSIBLE. <br />14. GENERAL CONTRACTOR IS RESPONSIBLE FOR MAINTAINING STABLE HUMIDITY TO <br />PROTECT NEW MILLWORK. ALL UNITS WILL BE INSPECTED BY CM WHEN RECEIVED FOR <br />COMPLIANCE WITH SHOP DRAWINGS, DAMAGE AND FINISH. ANY REPAIRS WILL BE <br />PERFORMED TO THE SATISFACTION OF CM. ALL MILLWORK WILL BE CLEANED AND <br />PROTECTED PRIOR TO TENANT'S MOVE IN, <br />15. MILLWORK FABRICATOR WILL FIELD MEASURE ALL AREAS TO RECEIVE UNITS. MAJOR <br />DISCREPANCIES WILL BE REPORTED TO CM PRIOR TO FABRICATION. <br />16. GC TO ENSURE THAT ALL OPENINGS AND PENETRATIONS IN DEMISING WALLS ARE <br />SEALED PER CODE, <br />17. GC TO ENSURE THAT ALL GYP IS TO BE TYPE X FIRE RATED, &THAT GREEN BOARD IS <br />USED ON ALL'WET WALLS (PANTRY LOCA T IONS, WET COLUMNS ETC.) & CEMENT BOARD <br />IN SHOWER LOCATIONS. <br />% ALL WOOD BLOCKING TO BE FIRE TREATED PER CODE. <br />19. ALL WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE APPROVED <br />ARCHITECTURAL AND PME FINAL ISSUE CONSTRUCTION SET, ANY CHANGES MADE <br />DURING CONSTRUCTION THAT ARE NOT IN COMPLIANCE WITH THE APPROVED PLANS <br />SHALL BE COORDINATED AND APPROVED BY THE CONSTRUCTION MANAGER OF VPI. <br />20. ELECTRICAL BOXES TO BE OFFSET IN ALL SOUND RATED PARTITIONS AT A MIN OF 24" <br />O.C. PROVIDE ONE STUD MIN BETWEEN OFFSET BOXES, INSTALL ACOUSTIC SEALANT <br />AROUND OPENINGS AND FIREPROOFING PUTTY AROUND J-BOXES AT FIRE -RATED <br />ASSEMBLIES. <br />21. THE PARTITION WITH THE HIGHEST FIRE RATING WILL RUN CONTINUOUS THROUGH <br />INTERSECTING AND PERPENDICULAR PARTITIONS. <br />22. ALL VOIDS BETWEEN <br />METAL DECKING AND <br />N TOP PLATE OF RATED PARTITION TO BE <br />PACKED TIGHT WITH THERMAFIBER BLANKETS. <br />23. FIBER BLANKET INSTALLATION TO BE THERMAFIBER SAFB'S OR APPROVED EQUAL WITH <br />MIN R-13 VALUE. <br />24. STUD GAUGE TO BE A MIN OF 20 WITH 1518" FLANGE WIDTH IN ACCORDANCE WITH ASTM <br />REQUIREMENTS C 645 <br />25. HEIGHT LIMIT OF STUDS TO BE IN ACCORDANCE WITH ANSI REQUIREMENTS AND GYPSUM <br />ASSOCIATION RECOMMENDATIONS. <br />26. IN WALL BLOCKING AND BACKING SHALL BE INSTALLED IN ALL ASSEMBLIES AS REQUIRED <br />TO MAINTAIN SPECIFIED FIRE RATINGS, TO COMPLY WITH EFFECTIVE FAIR HOUSING ACT <br />REQUIREMENTS AND TO COMPLY WITH ACCESSIBILITY CODE REQUIREMENTS. <br />27. ALL THRESHOLDS AT DOORWAYS TO BE <2 MAX. HEIGHT, BEVELED WITH 1:2 MAX. SLOPE, <br />28. NO PARTITIONS, RUNNING CHANNELS, OR BRACING SHALL BE ATTACHED TO THE SHELL <br />STRUCTURE. APPROVAL FROM LL, ENGINEER AND BUILDING OFFICIAL SHALL BE <br />OBTAINED PRIOR <br />ANY ATTACHMENT <br />TO SHELL DECK JOISTS, <br />OR BEAMS. <br />29. GC TO PROVIDE BLOCKING AS REQUIRED PER CONSTRUCTION MANAGER FOR MILLWORK <br />INSTALLATION. <br />30. GC TO INSTALL VPI SUPPLIED TACTILE SIGNS PER CODE. REFER TO SIGNAGE AND <br />PICTURES, THIS SHEET FOR SPECIFICATIONS. <br />31. GC VERIFY THAT EXIST DEMISING WALLS COMPLY WITH CODE. COORDINATE WITH CM <br />BEFORE MAKING NECESSARY ADJUSTMENTS TO BRING DEMISING WALL TO CODE. <br />32. GC VERIFY THAT EXIST DRINKING FOUNTAIN, EXIST WATER CLOSET, EXIST LAVATORY, <br />AND CLEARANCES IN EXST RESTROOM COMPLY WITH CODE. REFER TO ADA DETAILS. <br />COORDINATE WITH CM BEFORE ANY ADJUSTMENTS, <br />33. GC TO ENSURE THAT ALL EXISTING EXIT DOORS & INTERIOR DOORS SHALL COMPLY WITH <br />CODE LOCKS & LATCHES REQUIREMENTS. <br />34. AT ALL PARTITIONS, GYP. CEILINGS & GENERAL ITEMS ASSOCIATED WITH DEMOLITION - <br />G.C. TO PLASTER PATCH AND SKIM COAT ALL REMAINING SURFACES SMOOTH & MAKE <br />PLUMB. REMOVE & CLEAN ANY RESIDUAL RESIDUE ON PARTITION, WINDOW MULLIONS & <br />CONVECTORS. <br />35. G.C. TO FURNISH AND INSTALL (1) 3/4" THK SHEET OF F.R. PLYWOOD ON 21/2" F.R. STUDS <br />FOR TEL. EQUIPMENT, IN I.T. ROOM. FULL LENGTH OF THE WALL. <br />36. G.0 TO FURNISH AND INSTALL RECESSED PLYWOOD BLOCKING FOR ALL FLAT PANEL TVS, <br />ART WORK & WALL MOUNTED ITEMS. <br />37. G.C. TO FURR OUT CORE WALLS, COLUMNS & EXISTING PARTITIONS (AS REQ'D) FOR <br />FULLY RECESSED PLUMBING, ELECTRICAL WIRING, CONDUITS & J-BOXES. <br />38. WALL THICKNESS AS REQ'D FOR FULLY RECESSED ELEC, PANEL <br />39. GENERAL CONTRACTOR TO PATCH/REPAIR ANY CRACKS, DEVIATIONS, DIVOTS AND <br />ROUGH SURFACES ON EXISTING CONCRETE SLAB TO PROVIDE A SMOOTH CONTINUOUS <br />LEVEL SURFACE. G.C. IS TO V.I.F. IF HEAVY FLOOR PATCHING IS REQUIRED PRIOR TO <br />SUBMITTING BID. <br />40. CONTRACTOR IS TO FIREPROOF ANY EXISTING STEEL THAT IS EXPOSED BEFORE OR <br />DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR FIRESTOPPING ALL <br />DEMISING WALL OR SLAB PENETRATIONS (NEW OR EXISTING) IN ORDER TO MAINTAIN <br />FIRE RATINGS AS REQUIRED. <br />41. G.C. TO FURNISH MATERIAL DATA APPLICATION SHEETS FOR ANY AND ALL PRODUCTS OR <br />ASSEMBLIES USED FOR FIRESTOPPING. <br />42. GENERAL CONTRACTOR WILL REMOVE ALL DEBRIS & BROOM SWEEP PREMISES AT THE <br />END OF EACH WORK DAY, <br />43. CM SHALL APPROVE THE COMPLETE PARTITION LAYOUT (FLOOR TRACKS ONLY) BEFORE <br />CONSTRUCTION MAY CONTINUE. <br />44. DOORS, FRAMES & HARDWARE WITHIN UL RATED PARTITIONS SHALL CARRY THE <br />NECESSARY APPROPRIATE LABEL <br />45. GENERAL CONTRACTOR SHALL PROVIDE ANY ACCESS PANELS. (IF REQUIRED) FOR <br />ELECTRICAL. MECHANICAL. PLUMBING AND/OR DRAINAGE PIPES. LOCATION(S) AND <br />SIZE(S) TO BE APPROVED BY THE CM AND ENGINEER PRIOR TO INSTALLATION. <br />46. GENERAL CONTRACTOR AND FURNITURE VENDOR TO COORDINATE ALL FURNITURE <br />BLOCKING REQUIREMENTS AT OUTLET LOCATIONS. GENERAL CONTRACTOR NOT TO <br />CLOSE UP ANY WALLS/PARTITIONS UNTIL COORDINATION IS COMPLETED. REOPENING <br />PARTITIONS WILL BE AT G.C. COST, <br />FIRE PROTECT�ON SYSTEMS SPECIFICATIONS <br />ABBREVIATIONS- <br />1, <br />NOTE THAT THESE FIRE PROTECTION DRAWINGS ARE SCHEMATIC IN INTENT. NEW FIRE <br />ACT ACOUSTICAL CEILING TILE HT HEIGHT <br />PROTECTION SYSTEM SHALL MEET THE REQUIREMENTS OF: NFPA 13, NFPA 25, NFPA <br />ADJ ADJUSTABLE HVAC HEATING/VENTILATING/ <br />72, NFPA 170, 2018 INTERNATIONAL BUILDING CODE OF WASHINGTON, NATIONAL <br />AFF ABOVE FINISHED FLOOR AIR CONDITIONING <br />ELECTRIC CODE (NEC), 2017 NATIONAL ELECTRICAL CODE, THE LATEST EDITION OF <br />ALUM ALUMINUM INSUL INSULATION <br />UNDERWRITER'S LABORATORIES (UL) FIRE PROTECTION EQUIPMENT DIRECTORY, <br />ALT ALTERNATE LAV LAVATORY <br />FACTORY MUTUAL (FM) AND THE OWNER'S SEPARATE INSURANCE COMPANY & <br />ANOD ANODIZED LT(G) LIGHTING) <br />EQUIPMENT MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS AND DATA <br />BLDG BUILDING MAX MAXIMUM <br />SHEETS. <br />BOT BOTTOM MECH MECHANICAL <br />2. <br />INSTALLATION AND ACCEPTANCE TESTING OF ALL NEW FIRE PROTECTION EQUIPMENT <br />CL CENTER LINE MIN MINIMUM <br />SHALL BE IN ACCORDANCE WITH THE SPECIFICATIONS AND APPLICABLE NFPA <br />CLG CEILING MISC MISCELLANEOUS <br />STANDARDS. <br />CT CERAMIC TILE MTD MOUNTED <br />1 <br />THE CONTRACTOR SHALL SUBMIT TWO (2) COPIES OF FIRE PROTECTION DRAWINGS & <br />CJ CONTROL JOINT MTL METAL <br />HYDRAULIC CALCULATIONS STAMPED AND SIGNED BY A PROFESSIONAL ENGINEER <br />COL COLUMN OC ON CENTER <br />LICENSED IN WASHINGTON, <br />CONC CONCRETE OPP HND OPPOSITE HAND <br />4. <br />THE CONTRACTOR SHALL SUBMIT TWO (2) COPIES OF FIRE ALARM SYSTEM DRAWINGS <br />CM CONSTRUCTION MANAGER PLY PLYWOOD <br />STAMPED AND SIGNED BY A PROFESSIONAL ENGINEER LICENSED IN WASHINGTON. <br />CONT CON➢TINUE(OUS) P(D) PAINT(ED) <br />5. <br />THE CONTRACTOR SHALL SUBMIT TWO (2) COPIES OF SHOP DRAWINGS COVERING ALL <br />CS COVER SHEET PTO PAPER TOWEL DISPENSER <br />MATERIALS & EQUIPMENT BE FURNISHED. SUBMIT TO ARCHITECT FOR APPROVAL <br />DBL DOUBLE PT PORCELAIN TILE <br />PRIOR TO START OF WORK. ALL NEW EQUIPMENT SHALL BE CONSISTENT WITH <br />DET DETAIL REF REFERIREFERENCE <br />OWNER'S EXISTING EQUIPMENT SPECIFICATIONS, <br />DWG DRAWING RFI REQUEST FOR <br />6. <br />THE CONTRACTOR SHALL OBTAIN ALL PERMITS, LICENSES AND INSPECTIONS AND <br />EJ EXPANSION JOINT INFORMATION <br />SHALL PAY ALL LEGAL AND PROPER FEES AND CHARGES IN CONNECTION WITH THIS <br />ELEV ELEVATION RM ROOM <br />WORK. <br />ELEC ELECTRICAL SC SOLID CORE <br />7. <br />ALL WORK SHALL BE GUARANTEED FOR ONE (1) YEAR FROM DATE OF FINAL <br />EQ EQUAL SCHED SCHEDULE(D) <br />ACCEPTANCE. <br />EQ-## EQUIPMENT BHT SHEET <br />8. <br />THE CONTRACTOR SHALL PROVIDE FOUR (4) SETS OF RECORD DRAWINGS AND <br />EXT EXTERIOR SIM SIMILAR <br />OPERATING AND MAINTENANCE MANUALS AND INSTRUCT THE OWNER'S PERSONNEL IN <br />EXST EXISTING SPEC SPECIFICATIONS) <br />OPERATION OF EQUIPMENT AND SYSTEMS. <br />FIN FINISHED) STL STEEL <br />FRP FIBERGLASS REINFORCED PANEL STRUCT STRUCTURE(AL) <br />CUTTING AND REFINISHING: <br />FX-## FIXTURE(S) TEMP TEMPERED <br />1. <br />ALL CUTTING, FITTING, REPAIRING, PAINTING AND FINISHING OF MASONRY AND <br />FLR FLOOR TPD TOILET PAPER DISPENSER <br />CARPENTRY WORK, ETC„ THAT MAY BE NECESSARY FOR THE OPERATIONS REQUIRED <br />F-## FURNITURE TS TUBULAR STEEL <br />BY THIS CONTRACTOR SHALL BE DONE BY CRAFTSMEN SKILLED IN THEIR RESPECTIVE <br />GA GAUGE, OR GAGE TYP TYPICAL <br />TRADES AND AT THE EXPENSE OF THIS CONTRACTOR UNLESS OTHERWISE NOTED, IN A <br />GC GENERAL CONTRACTOR VIF VERIFY IN FIELD <br />MANNER APPROVED BY THE ARCHITECT. <br />GL GLASS VCT VINYL COMPOSITION TILE <br />2. <br />THE CONTRACTOR SHALL COORDINATE ALL SPRINKLER HEAD INSTALLATION Wl <br />GYP GYPSUM BOARD VPI VISIONARY PROPERTIES, INC, <br />STRUCTURE, DUCTWORK, DIFFUSERS, LIGHTS AND THE REFLECTED CEILING PLAN. <br />HC HOLLOW CORE WC WATER CLOSET <br />3, <br />EXISTING CEILING TILES ARE TO BE REMOVED AND REINSTALLED BY THIS <br />HDWR HARDWARE WD WOOD <br />CONTRACTOR WHERE WORK OCCURS ABOVE THE SAME, UNLESS OTHERWISE NOTED. <br />WH WATER HEATER <br />ANY DAMAGE TO CEILINGS AS A RESULT OF HIS WORK SHALL BE REPAIRED BY THIS <br />YP YELLOW PINE <br />CONTRACTOR, ALL TILES SHALL BE LEFT IN A CLEAN AND UNDAMAGED CONDITION. <br />4. <br />CUT DRYWALL CEILINGS WHERE WORK OCCURS ABOVE SAME, PATCH CEILINGS TO <br />MATCH ADJACENT SURFACES. CUTTING AND PATCHING OF CEILINGS SHALL BE DONE <br />BY THIS CONTRACT OR. <br />SICACE AND PICTURES: <br />5, <br />CUT EXISTING WALLS AND FLOORS AS REQUIRED FOR NEW WORK UNLESS OTHERWISE <br />NOTED. PATCH TO MATCH ADJACENT SURFACES. <br />NOTE: <br />1. ALL TACTILE SIGNS, 43, AND 50 FRAMES PICTURES ARE SUPPLIED BY VPI <br />SMOKE DETECTORS & CARBON MONOXIDE DETECTORS: <br />AND INSTALLED BY GC. <br />1. <br />REUSE EXISTING UNITS WHERE POSSIBLE, PROVIDE NEW UNITS TO MATCH EXISTING <br />2. ALL TACTILE SIGNS TO BE INSTALLED PER ICC Al17,1-2009. <br />AS REQUIRED. Q <br />ACCESSIBLE SEATING DESIGNATION SIGN: LOCATE ONE IN EACH DESIGNATED <br />2. <br />PROVIDE NEW UNITS BY KIDDE OR APPROVED EQUAL. <br />A O WAITING AREA LOCATION. PLACE ON CHAIR RAIL IN WAITING AREA WHERE <br />WHEEL CHAIR SEATING IS DESIGNATED PER PLAN, <br />AUDIO/VISUAL ANNUNCIATORS: <br />1. <br />REUSE EXISTING UNITS WHERE POSSIBLE. PROVIDE NEW UNITS TO PATCH EXISTING <br />ACCESSIBLE EXIT SIGN: LOCATE ONE AT EACH EXTERIOR EXIT. SIGN SHOULD <br />AS REQUIRED. <br />B BE MOUNTED 9" FROM DOOR TO CENTER OF SIGN AND 48" MIN AFF TO THE <br />2. <br />PROVIDE NEW UNITS BY SIMPLEX OR APPROVED EQUAL. <br />BOTTOM OF THE LOWEST TACTILE LETTERING AND 60" MAX AFF TO HIGHEST <br />TACTILE LETTERING. PLACE ON WALL AT EACH EXIT <br />MANUAL PULL STATIONS: <br />1, <br />REUSE EXISTING UNITS WHERE POSSIBLE, PROVIDENEW UNITS TO MATCH EXISTING <br />ACCESSIBLE RESTROOM SIGN: LOCATE ONE AT EACH ACCESSIBLE RESTROOM <br />AS REQUIRED. r <br />C ILt LOCATION, SIGN SHOULD BE MOUNTED 9" FROM DOOR TO CENTER OF SIGN AND <br />2. <br />PROVIDE NEW UNITS BY SIMPLEX OR APPROVED EQUAL. ' tl. <br />48 MIN AFF TO THE BOTTOM OF THE LOWEST TACTILE LETTERING AND 60 MAX <br />AFF TO HIGHEST TACTILE LETTERING, PLACE ON WALL AT EACH RESTROOM. <br />FIRE EXTINGUISHERS: <br />1. <br />PORRTABLELE FIRE EXTINGUISHERS &INSTALLATION LOCATIONS ARE TO COMPLY WITH • <br />ROOM DESIGNATION SIGN: LOCATE ONE AT THE ENTRANCE/DOOR TO EACH ROOM. <br />THE 2018 INTERNATIONAL BUILDING CODE OF WASHINGTON AND NFPA.. <br />SIGN SHOULD BE MOUNTED 9" FROM DOOR TO CENTER OF SIGN AND 48" MIN AFF <br />D � <br />2. <br />FINAL INSTALLATION SHOULD COMPLY WITH THE 2018 INTERNATIONAL FIRE CODE OF <br />TO THE BOTTOM OF THE LOWEST TACTILE LETTERING AND 60" MAX AFF TO <br />WASHINGTON. FIRE EXTINGUISHER SHOULD BE MOUNTED MIN. 4" AFF & NO HIGHER <br />HIGHEST TACTILE LETTERING. PLACE ON W,�LL AT EACH ROOM LOCATION. <br />THAN 27" AFF. <br />3. <br />CONTRACTOR TO VERIFY REQUIRED TYPES & ADDITIONAL REQUIRED LOCATIONS WITH <br />50 FRAMED PICTURE: LOCATE ONE AT EACH LOCATION <br />THE OWNER, <br />E <br />DESIGNATED BY THE FLOOR PLAN. PICTURES SHALL BE <br />4, <br />CONTRACTOR TO COORDINATE ANY CHANGES WITH THE ARCHITECT & OWNER,' <br />MOUNTED SO THAT THE TOP OF THE FRAME IS 7'-2" AFF. <br />5. <br />WALL MOUNTED FIRE EXTINGUISHERS TO HAVE MANUFACTURER'S STANDARD" <br />MOUNTING BRACKET UNLESS NOTED OTHERWISE. <br />VISIONWORKS LOGO AND LETTERS: LOCATE ONE AT <br />F- EACH LOCATION DESIGNATED BY THE FLOOR PLAN. <br />LOGO AND LETTERS SHALL BE MOUNTED SO THAT THE <br />BOTTOM OF THE LOGO AND LETTERS ARE T-4" AFF. <br />EYE EXAMS LETTERS: LOCATE ONE AT EACH LOCATION DESIGNATED BY <br />G THE FLOOR PLAN. LETTERS SHALL BE MOUNTED SO THAT THE BOTTOM <br />OF THE LETTERS ARE T-4" AFF, <br />3x4 FRAMED PICTURE: LOCATE ONE AT EACH LOCATION <br />H <br />DESIGNATED BY THE FLOOR PLAN. PICTURES SHALL BE MOUNTED <br />SO THAT THE TOP OF THE FRAME IS T-2" AFF. <br />RETAIL PROMOTIONAL WINDOW BANNER: LOCATE ONE AT EACH <br />IR <br />LOCATION DESIGNATED BY THE FLOOR PLAN, ENSURE THAT ADA <br />CLEARANCES ARE MET, <br />PROMOTIONAL METAL TWO TIER SIGN: LOCATE ONE AT EACH <br />J <br />LOCATION DESIGNATED BY THE FLOOR PLAN. ENSURE THAT ADA <br />L <br />CLEARANCES ARE MET. <br />PROMOTIONAL WINDJAMMER SIDEWALK SIGN: LOCATE ONE AT <br />K STOREFRONT DOORS DESIGNATED BY THE FLOOR PLAN. ENSURE <br />THAT ADA CLEARANCES ARE MET. <br />L LED LIGHT BOX: LOCATE ONE AT EACH LOCATION DESIGNATED BY <br />THE FLOOR PLAN. ENSURE THAT ADA CLEARANCES ARE MET. <br />LENS UPGRADE FLOOR STAND: LOCATE ONE AT EACH LOCATION <br />M DESIGNATED BY THE FLOOR PLAN. ENSURE THAT ADA <br />CLEARANCES ARE MET, <br />ICC Al 17®1- 00 <br />ADA &/OR BARRIER FREE HANDICAPPED <br />ACCESSIBILITY GUIDELINES <br />*WHERE BOTH CLOSER & ** 52" MIN, IF NEW <br />LATCH ARE PROVIDED BUILDING <br />I II I <br />I II I <br />6- 0" MIN. 4'- 0" MIN.** I <br />Y►i r - s ■ r Y: <br />- ! <br />- NO OTHER FIXTURES <br />ALLOWED IN THIS AREA <br />G <br />um <br />00 <br />L - - - - - <br />I 5'-0"MIN. <br />SIZE OF CLEARANCE <br />FOR WATER CLOSET <br />I <br />--L- <br />ALT. DOOR <br />LOCATION I <br />I <br />16" TO 18" ADULT <br />12" TO 18" CHILD <br />z <br />0o <br />�-8- <br />2'-8" T-6 MIN. <br />o 2'-0" <br />MIN. <br />MIN. MIN. <br />�� <br />MIN. <br />* 12" MIN. IF BOTH LATCH & CLOSER ARE PROVIDED <br />* 48" MIN. IF BOTH LATCH & CLOSER <br />*k 48" MIN. IF BOTH LATCH & CLOSER ARE PROVIDED <br />ARE PROVIDED <br />*' 54" MIN. IF CLOSER IS PROVIDED <br />HINGE <br />LATCH APPROACH <br />APPROACH <br />4" MAX. / z <br />�r - <br />�o <br />5' 0" MIN: <br />*8" MEN TOILET COMPARTMENT TOE CLEARANCE <br />ADULT WALL HUNG WATER <br />CLOSET COMPARTMENT <br />CO c.s <br />36" MIN <br />A <br />1 I <br />I I <br />L_ - - - - -I <br />PARALLEL APPROACH AT SALES <br />COUNTER <br />39"-41" <br />T - 6" MIN, * = 1-1/2" MIN. T - 6" MIN <br />- 0" T - 6" MIN. - ** = 12" MIN. 6" MAX <br />3'- 0" MIN <br />1AX. <br />r z 1-1/4"-2" <br />1-z <br />co <br />SIZE OF CLEARANCE FOR WATER <br />CLOSET (SIDE WALL) <br />I <br />ALT, DOORI <br />LOCATION I <br />I <br />L- <br />SIZE OF CLEARANCE FOR WATER <br />CLOSET (REAR WALL) <br />4" MAX. j <br />5'- 0MIN. <br />- -- - co <br />*8" MIN TOILET COMPARTMENT TOE CLEARANCE <br />ADULT FLOOR MOUNT WATER, <br />25" MAX. CLOSET COMPARTMENT <br />8" MIN. <br />11" MIN, <br />HEIGHT OF HEIGHT OF <br />LAVATORIES &_SINKS URINALS <br />30" MIN <br />X � <br />FORWARD APPROACH AT SALES COUNTER/ <br />SERVICE TABLES <br />W/C COMPARTMENT ELEVATION <br />I A <br />�o <br />I I <br />I I <br />30" MIN. <br />DRINKING FOUNTAIN <br />SPOUT LOCATION <br />5" MAX. <br />I 1 <br />M h I <br />11" MIN. <br />BI-LEVEL ADA DRINKING FOUNTAIN <br />OWNER <br />VISIONWORKS <br />175 E HOUSTON STREET <br />SAN ANTONIO, TX 78205 <br />PROJECT <br />VISIONWORKS #1407 - GREENTREE PLAZA <br />305 SE EVERETT MALL WAY, SUITE 21 <br />EVERETT, WA 98208 <br />CONTACT <br />0.716.884.0059 <br />F. 716.884.6414 <br />SCHEIDAIA.COM <br />i# ISSUE DATE DESCRIPTION <br />08/27/2021 CHECK SET <br />09101/2021 PERMIT SET <br />SEAL/SIGNATURE <br />11482 REGISTERED <br />ARCHITECT <br />GLAS <br />This drawing is copyrighted under the United States Copy Right Law and is the property <br />of Scheid Architectural, the use of this drawing in any form without written permission is <br />strictly prohibited. <br />SHEET TITLE <br />GENERAL ®TES & DETAILS <br />R46EVIE ED 0 R PE hMIT <br />VHEET <br />Ewa <br />"�.� � to <br />00 <br />