Laserfiche WebLink
TF 1 <br />0k 5 - <br />P=21.g.. 3026" <br />CKT-22 <br />JJI RESTR00 <br />P21B.., 111 <br />CKI--23 <br />01 <br />P-21 B <br />CKT-15 <br />JII RESTR0M <br />'110 <br />STORAGE 1' <br />CORRIDOR 107 <br />... <br />REFRACTING P-21 B PRE -TEST <br />103 19 CKT-12 102 P-21 B <br />21 21 '2� CKT-10 <br />CKT-11....... <br />3 <br />I <br />10'-3" <br />M <br />Im <br />on <br />P-21 B P-21 B <br />CKT-2 CKT-6 <br />_�• - - ® 24" <br />86" <br />�1 E LAB <br />�� SCALE: 3/16'° =1°-®" �' NORTH <br />PANEL SCHEMATIC <br />PROJECT NAME: VISIONWORKS 91407 - GREENTREE PLAZA <br />100 A <br />PANEL DESIGNATION: P-21A <br />MAIN BREAKER: <br />100 A <br />VOLTAGE: 1201208 <br />PANEL TYPE: <br />EXISTING <br />PHASE: 3 <br />NUMBER CIRCUITS: <br />26 <br />NUM. WIRES: 4 <br />TOTAL CONNECTED: <br />85 A <br />MOUNTING: SURFACE <br />OTHER: <br />CU BUS GROUNDING BAR <br />NO. <br />AMP <br />LOAD <br />POLES <br />WATTS A <br />WATTS B <br />'WATTS C <br />POLES <br />LOAD <br />AMP <br />NO. <br />9 <br />20 A <br />SPARE <br />1 <br />0 <br />LIGHTING - RETAIL <br />20 A <br />2 <br />3 20 A SPARE <br />1 <br />„' <br />0 290 <br />1 <br />LIGHTING - EMERGENCY <br />20 A <br />4 <br />5 20 A EXISTING J BOX - SIGN <br />1 <br />500 <br />680 <br />1 <br />LIGHTING -REAR <br />20 A <br />6 <br />7 20 A SPARE <br />1 <br />0 <br />5757 <br />., <br />8 <br />9 20 A SPARE <br />1 <br />0 5757` <br />3 <br />RTU.1 <br />60 A <br />10 <br />11 20 A SPARE <br />1... <br />„. ` .. <br />.. <br />0 <br />5757 <br />12 <br />13 20A SPARE <br />1 <br />0 <br />0 <br />1 <br />SPARE <br />20 A <br />14 <br />15 20 A SPARE <br />1 <br />0 0 <br />1 <br />SPARE <br />20 A <br />16 <br />17 <br />0 <br />0 <br />1 <br />SPARE <br />20 A <br />18 <br />20 A SPARE <br />2 <br />19 <br />0 <br />3718 <br />20 <br />21 <br />0 3718 <br />3 <br />RTD-2 <br />40 A <br />22 <br />20 A SPARE <br />23 <br />2 <br />0 <br />3718 1 <br />24 <br />25 20 A SPARE <br />1 <br />SPARE <br />20 A <br />26 <br />TOTAL WATTS <br />10583 <br />9709 <br />10444 <br />BOLD "AMP" INDICATES NEW CIRCUIT BREAKER <br />BOLD "LOAD" INDICATES NEW ITEM BEING CIRCUITED TO EXISTING CIRCUIT <br />BREAKER <br />Wzli <br />AMPS: 100 A <br />i <br />• ANEL <br />TYPE: SQUARE t OR EQUAL <br />r, <br />, <br />4 <br />OUTLETS * .. RETAIL <br />4 i <br />OUTLETS DISPLAY BOXES * RETAIL <br />A <br />OUTLETS BARRETAIL{ <br />r DISPLAY BOXES - RETAIL� <br />x <br />1 A <br />r A R - RETAIL <br />1 i t <br />; <br />OUTLETS - RETAIL 10! <br />r <br />1 A <br />! <br />_ <br />! 11 <br />•UTLETS - CORRID1 <br />OUTLETS - CONTACT 1REF <br />_ <br />+ <br />RACTING <br />OUTLETS - CONTACT <br />i <br />OUTLETS - REFRACTING 103 <br />, <br />OUTLETSv, <br />A <br />OUTLETS CONTACT <br />1.1REFRACTING <br />A <br />rUTLETS - R r{ <br />REFRACTINGOUTLETS <br />- BREAK 115 <br />tOFFICE <br />, <br />- MANAGER OFFICE 106, <br />DIED OUTLET - IT RACK -11T�l <br />�: <br />+1 <br />• • OUTLET RACK IT 112 <br />! <br />� <br />! <br />HI <br />i <br />DRINKING FOUNTAII <br />HOT WATER HEAT <br />, <br />F <br />TOTAL WATTS <br />:.a <br />® POWER PLAN KEY NOTES <br />M <br />18 <br />P-21 A 4 <br />CKT-5� <br />EXISTING INCOMING <br />SERVICE <br />EXISTING MAIN PANEL <br />EXISTING r- <br />I <br />ELECTRIC <br />® <br />N1 <br />P-21A <br />100A <br />P-21B LC -A" <br />100A <br />METER <br />1 <br />#21 <br />#22 <br />120/208 <br />120/208 <br />3PH <br />3PH <br />EXISTING 100 <br />i) <br />AMP DISCONNECT <br />1 <br />®, <br />Cn <br />� <br />EXISTING - NEW <br />< <br />ELECTRICAL ELECTRICAL <br />----- <br />FINISH FLOOR <br />----- <br />-- <br />--------------------- <br />I <br />L <br />PANEL PANEL <br />SINGLE LINE DIAGRAM <br />L1/4= 1-0 <br />LUI } SYSTEM SMOKE SENSOR <br />WITH SOUNDER BASE <br />VISUAL STROBE IN ADA & <br />PUBLIC AREAS <br />— CT_r-rK <br />THER6�10STAT <br />0 0 W LIGHT SWITCH <br />rn 0 U <br />RECEPTACLE <br />4 DEVICE HEIGHT INSTALLATION <br />SCALE: NTS <br />METAL JOIST <br />1/2" GALV, ROD MIN. <br />LOCK NUT <br />ELECTRICAL LEGEND. <br />DUPLEX RECEPTACLE <br />QUADRUPLEX RECEPTACLE <br />DEDICATED DUPLEX RECEPTACLE <br />DEDICATED QUADRUPLEX RECEPTACLE <br />GROUND FAULT INTERRUPTED DUPLEX RECEPTACLE <br />DEDICATED GROUND FAULT INTERRUPTED DUPLEX RECEPTACLE <br />(X) X" > <br />DATA <br />(X) INDICATES # OF PORTS <br />X" INDICATES ELEVATION <br />SINGLE GANG BOX WITH BRUSH PLATE (HOME DEPOT <br />SKU #1001863171) WITH PULL STRING <br />TELEPHONE <br />® <br />JUNCTION BOX - LOW VOLTAGE <br />SU <br />STUB -UP <br />ELECTRICAL PANEL <br />Xx <br />'LIGHT TYPE' LIGHT FIXTURE PER SCHEDULE <br />"X" INDICATES FIXTURE TYPE <br />"x" INDICATES SWITCHING <br />® X� <br />RECESSED CAN LIGHT FIXTURE PER SCHEDULE <br />"X" INDICATES FIXTURE TYPE <br />"x" INDICATES SWITCHING <br />EMERGENCY LIGHT FIXTURE / 24HR KITE <br />LIGHT PER SCHEDULE <br />0 <br />EMERGENCY EXIT SIGN PER SCHEDULE <br />—� <br />HOME RUN TO PANEL <br />KT <br />"X" INDICATES PANEL <br />°x° <br />Y' INDICATES CIRCUIT NUMBER <br />SINGLE LIGHT SWITCH <br />THREE-WAY LIGHT SWITCH <br />DIMMER SWITCH <br />THREE-WAY DIMMER SWITCH <br />SINGLE LIGHT SWITCH W/ OCCUPANCY SENSOR <br />SINGLE LIGHT SWITCH W/ OCCUPANCY SENSOR 8r DIMMER <br />OS <br />CEILING MOUNTED OCCUPANCY SENSOR - FOR <br />EMEREGENCY EGRESS LIGHTING ONLY. <br />DISPLAY <br />RETAIL LIGHTING <br />NON -PROGRAMMABLE <br />LIGHTING CONTACTOR <br />r IR <br />GALVANIZED UNISTRUT 8'-0" <br />O/C MAXIMUM <br />1'-0" MAXIMUM SIZE ON <br />BOTTOM OF UMSTRUT <br />MULTIPLE ELECTRICAL CONDUIT <br />�� LE <br />SCALE: NTS <br />ELECTRICAL SPCEICATICNS <br />A. ALL WORK SHALL CONFORM TO THE LATEST DATED NEC, AND LOCAL CODES, <br />B. ALL RELATIVE REQUIREMENTS OF THE NEC, ASTM, OSHA, NEMA, AND ADA SHALL BE <br />ADHERED TO THROUGHOUT THE PROJECT. <br />C. THE EC (ELECTRICAL CONTRACTOR) SHALL MAINTAIN A LICENSE IN GOOD STANDING IN <br />THE MUNICIPALITY IN WHICH THE WORK IS BEING PERFORMED. <br />D THE EC SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS <br />E. <br />THE EC SHALL MAINTAIN A SET OF MARKED UP PRINTS TO PROVIDE AN "AS BUILT" <br />�.�� ����'. <br />RECORD OF ALL INSTALLED WORK, ALL CHANGES, AND INDICATING ALL DIMENSIONS <br />A�„� <br />FOR UNDERGROUND WORK. THIS SHALL BE PROVIDED BEFORE THE SUBMITTAL OF <br />THE FINAL INVOICE. <br />F. <br />THE EC SHALL HAVE THE WORK REGULARLY INSPECTED BY THE LOCALLY ADOPTED <br />AUTHORITY AND PROVIDE A CERTIFICATE OF APPROVED INSTALLATION UPON <br />COMPLETION. <br />G. <br />THE SITE SHALL BE MAINTAINED IN A CLEAN AND SAFE CONDITION DURING <br />CONSTRUCTION, AND LEFT IN A CLEAN, NEAT, AND SAFE CONDITION AT THE <br />COMPLETION OF THE PROJECT. <br />H. <br />ALL TOOLS, MATERIALS, AND EQUIPMENT SHALL BE STORED, MOVED, AND HANDLED IN <br />A SAFE MANNER TO PREVENT INJURY TO PERSONNEL OR STRUCTURES. <br />OWNER <br />1. <br />ALL WORKMEN SHALL BE SKILLED IN THE TRADES AND PERFORM THEIR WORK IN A <br />VISIO WORKS <br />WORKMANLIKE MANNER. <br />175 E HOUSTON STREET <br />175E OUSTO <br />J, <br />ALL LABOR, TOOLS, MATERIALS, EQUIPMENT, SUPERVISION, ETC., SHALL BE PROVIDED <br />SAN ANTONIO, TX 78205 <br />IN A TIMELY MANNER TO PRODUCE A COMPLETE AND WORKING PROJECT AS TO THE <br />INTENT INDICATED BY THE DRAWINGS AND SPECIFICATIONS. ALL PREMIUM TIME <br />V�SPROJECT <br />#1407 - GREENTREE PLAZA <br />SHALL BE INCLUDED IN THE BID PRICE. <br />305 SE EVEREORKS <br />SE EVERETT MALL WAY, SUITE 21 <br />K, <br />ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF <br />EVERETT, WA 98208 <br />EV <br />ACCEPTANCE. ANY FAILURE OF MATERIALS OR WIRING DURING THAT TIME SHALL BE <br />REPAIRED OR REPLACED AT NO COST TO THE OWNER. <br />L. <br />THE EC SHALL CONTACT THE CONCERNED UTILITY COMPANY AS TO ANY CHANGES <br />THAT WILL EFFECT THE ELECTRICAL SERVICE <br />M. <br />A COMPLETION SCHEDULE SHALL BE PROVIDED WITH THE BID. <br />M <br />THE EC SHALL VISIT THE SITE BEFORE SUBMITTING A BID TO BECOME FAMILIAR WITH <br />�3 <br />THE WORKING CONDITIONS. <br />0. <br />THE EC SHALL PROVIDE INSURANCE CERTIFICATES TO THE OWNER BEFORE STARTING <br />WORK. <br />P. <br />THE EC SHALL HAVE A TRAINED SUPERVISOR IN CHARGE WHENEVER ELECTRICAL.,, <br />,. <br />WORK IS BEING PERFORMED. <br />Q. <br />THE EC SHALL COOPERATE WITH THE GC (GENERAL CONTRACTOR) AND PROVIDE <br />LABOR AND MATERIAL IN A TIMELY FASHION TO ADEQUATELY COMPLETE THE WORK <br />AND MAINTAIN THE COMPLETION SCHEDULE, <br />x <br />INSTALLATION <br />SCHEID <br />A. <br />ALL WORK SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. <br />rt'' C nz, <br />B. <br />ALL EXPOSED WORK SHALL BE PLUMB AND PARALLEL TO MAJOR BUILDING LINES. <br />C. <br />ALL EQUIPMENT (CONDUIT, BOXES, PANELS, SWITCHES, ETC.) SHALL BE SECURELY <br />SUPPORTED FROM THE PRIMARY BUILDING STRUCTURE. <br />CONTACT <br />D. <br />NEWLY INSTALLED MATERIALS AND EQUIPMENT SHALL NOT INTERFERE WITH ACCESS <br />0.716.884.0059 <br />TO EXISTING EQUIPMENT TO BE REUSED, <br />F. 716,884.6414 <br />E. <br />ALL RACEWAYS SHALL BE MAINTAINED CLEAR OF FOREIGN MATERIALS AND WIRE <br />SCHEIDAIA.COM <br />SHALL BE INSTALLED IN A MANNER TO PREVENT INJURY TO THE INSULATION OR <br />— <br />CONDUCTORS. <br />F. <br />RACEWAYS SHALL BE SQUARE CUT, FREE OF BURRS, AND TERMINATED WITH <br />INSULATED BUSHINGS AND ENDS. <br />G. <br />RACEWAYS PASSING FROM WARM TO COLD AREAS SHALL BE SEALED USING <br />APPROVED FITTINGS. <br />H. <br />WIRE TERMINATIONS SHALL NOT HAVE EXCESS CONDUCTORS EXPOSED. <br />1. <br />WIRE SPLICES SHALL BE MADE WITH SOLDERLESS PRESSURE TYPE CONNECTORS <br />AND PROPERLY INSULATED, <br />J. <br />ALUMINUM WIRE SPLICES AND TERMINATIONS SHALL USE ANTI -OXIDANT COMPOUNDS <br />N THE CONDUCTORS. <br />K. <br />ALL CUTTING AND PATCHING SHALL BE DONE IN A MANNER THAT WILL NOT WEAKEN <br />ANY STRUCTURAL OR SUPPORTING MEMBERS. ALL SURROUNDING AREAS SHALL BE <br />RETURNED TO THE PREVIOUS CONDITION OF THE SURROUNDING AREA. <br />L. <br />THE EC SHALL NOTIFY THE GC AND THE ARCHITECT/ENGINEER OF ANY <br />QUESTIONABLE CONDITION THAT MAY EFFECT THE SATISFACTORY INTENT OF THE <br />COMPLETED PROJECT. <br />M. <br />LABEL ALL SWITCHES, PANELS, FEEDERS, ETC. AND PROVIDE EACH PANEL WITH A <br />TYPEWRITTEN DIRECTORY. <br />N, <br />ALL CUTTING AND PATCHING REQUIRED FOR THE NEW WORK SHALL BE THE <br />RESPONSIBILITY OF THE EC. ALL SURFACES SHALL BE PATCHED WITH MATERIALS <br />SIMILAR TO THE ADJACENT AREAS. CHASES IN CONCRETE SHALL BE MADE WITH SAW <br />CUTS TO PROVIDE A CLEAN EDGE TO FINISH. <br />MATERIALS <br />_ <br />A. <br />ALL MATERIALS SHALL BE NEW AND BARE THE UL LABEL WHERE APPLICABLE. <br /># ISSUE DATE DESCRIPTION <br />B. <br />RIGID GALVANIZED STEEL CONDUIT SHALL BE USED WHERE EXPOSED TO PHYSICAL <br />08/27/2021 CHECK SET <br />DAMAGE OR MOISTURE. <br />09/01/2021 PERMIT SET <br />C. <br />PVC SHALL BE USED UNDERGROUND, WHEN IN CONCRETE. <br />D. <br />EMT SHALL BE USED INDOORS WHERE EXPOSED. <br />E. <br />USE LIQUID TIGHT FLEXIBLE CONDUIT TYPE UA COMPLETE WITH APPROVED FITTINGS <br />FOR SHORT CONNECTIONS (LESS THAN 6') TO VIBRATING OR ADJUSTABLE <br />EQUIPMENT. <br />F. <br />UNLESS OTHERWISE SPECIFIED, WIRE SHALL BE 98% CONDUCTIVITY COPPER WITH <br />600V TYPE THHN, THWN, OR XHHW INSULATION. No. 8 AND LARGER SHALL BE <br />STRANDED. No. 10 AND SMALLER MAY BE STRANDED. <br />G. <br />PULL, SPLICE, AND OUTLET BOXES SHALL BE MINIMUM SIZE OR LARGER AS PER NEC <br />REQUIREMENTS, WEATHER PROOF BOXES SHALL_ BE CAST OR SEAM WELDED <br />GALVANIZED STEEL AND PROVIDED WITH A GASKETED COVER. BRASS SCREWS SHALL <br />BE USED TO SECURE THE COVER WHEN EXPOSED TO MOISTURE. <br />H. <br />BRANCH PANELS SHALL BE CIRCUIT BREAKER TYPE SIMILAR TO SQ. D CO, NQOD TYPE <br />UNLESS OTHERWISE SPECIFIED. <br />1. <br />SAFETY SWITCHES SHALL BE FUSED, HEAVY DUTY TYPE AND OF THE AMPACITY AND <br />VOLTAGE INDICATED, <br />J. <br />WIRING DEVICES SHALL BE COMMERCIAL SPECIFICATION GRADE AND COLOR AS <br />SELECTED BY THE ARCHITECT/ENGINEER. <br />K. <br />CONCEALED WIRING OVER SUSPENDED CEILINGS OR IN PARTITIONS MAY BE WIRED <br />USING METALLIC SHEATHED CABLE (MC) WITH COPPER CONDUCTORS AND AN <br />INSULATED GROUNDING CONDUCTOR. ALL CONDUCTORS SHALL BE PROTECTED AS <br />PER NEC. ALL WIRING SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING AND <br />THE CEILING SUPPORT SYSTEM, <br />18" MIN <br />NOTE: <br />MINIMUM OF 90 DEGREE TOTAL BEND <br />REQUIRED BETWEEN BOXES FOR <br />SOUND ATTENUATION <br />® VOLT WALL RECEPTACLE <br />SCALE: NTS <br />SEAL/SIGNATURE <br />�' �•`� REGISTERED: <br />�.-.._ ECT <br />This drawing is copyrighted under the United Stapes Copy Right Law and is the prope ty <br />of Scheid Architectural, the use of this drawing in any form without written permission is <br />strictly prohibited. <br />SHEET TITLE <br />POWER LAN & DETAILS <br />iHEET <br />E-1 <br />