111 <br />1 <br />� <br />FINISH PLAN_ <br />NORTH <br />FINISH <br />FLOOR FINISH TRANSITION TO COMPLY TO ICC/ <br />WALL FINISH <br />P-1 <br />F-1 <br />FLOOR FINISH <br />PT-1 INDICATES EXTENT OF FINISH <br />WALL FINISH <br />1. SEE FINISH SCHEDULE ON SHEET A9-1. <br />2. ALL FINISH SELECTIONS IDENTIFIED IN LEGENDS AND FINISH SCHEDULES ARE <br />NOT SUBJECT TO 'OR EQUAL' SUBSTITUTIONS U.N.O. THE CONTRACTOR AND <br />SUBCONTRACTORS SHALL SUBMIT PRODUCTS AND FINISHES AS INDICATED IN <br />THE DOCUMENTS. <br />3. NOTIFY DESIGNER OF SCHEDULED FINISHES THAT ARE UNAVAILABLE OR <br />DISCONTINUED AT THE EARLIEST OPPORTUNITY SUCH THAT A SUBSTITUTION <br />CAN BE SELECTED WITHOUT JEOPARDIZING THE CONSTRUCTION SCHEDULE. <br />4. REFER TO THE FINISH SCHEDULE FOR MANUFACTURER, PRODUCT/STYLE NAME, <br />COLOR SPECIFICATION. <br />5. INSTALL. ALL FINISH MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S <br />RECOMMENDED SPECIFICATIONS, SURFACE PREPARATION, ADHESIVES AND <br />BACKINGS: INCLUDING WALL COVERINGS, COATINGS, FLOORING MATERIALS, <br />LAMINATES, ETC. <br />6. THE CONTRACTOR SHALL REPAIR ALL ROUGH FLOOR SLAB UNEVENNESS <br />SUITABLE FOR PROPER FLOOR COVERING INSTALLATION. <br />7. FLOOR MATERIAL TRANSITIONS AT DOOR OPENINGS ARE TO BE CENTERED <br />BELOW THE DOOR IN THE CLOSED POSITION, U.N.O. <br />8. THE PAINTING SUBCONTRACTOR SHALL ENSURE THAT ALL PAINTS COMPLY <br />WITH THE MUNICIPAL & STATE CODES AND BUILDING REGULATIONS FOR LOW <br />VOC EMISSIONS. <br />9. ELECTRICAL SWITCH AND OUTLET COVER PLATES, SURFACE HARDWARE, ETC. <br />SHALL BE INSTALLED AFTER PAINTING AND/OR APPLICATION OF WALL <br />COVERINGS AND SPECIFIED CARPET. <br />10. PROVIDE METAL. TRANSITION STRIPS AT ALL FLOORING MATERIAL CHANGES, <br />U.N.O. TRANSITION STRIPS TO STAINLESS STEEL U.N.O. REFER TO PLAN FOR <br />DETAIL LOCATIONS. <br />11. HARD FLOORING GROUT IS -TO BE SEALED WITH MANUFACTURER'S <br />RECOMMENDED SEALERS. <br />12. RUBBER/VINYL BASE SHALL BE COVED BASE AT ALL LOCATIONS FOR CARPET <br />AND COVE BASE AT RESILIENT FLOORS. <br />13. RUBBER BASE SHALL RUN CONTINUOUSLY AND FULLY SURROUND CABINET <br />BASES ON ALL EXPOSED SIDES. <br />14. ALL ELECTRICAL PANELS VISIBLE IN OTHER THAN ELECTRICAL ROOMS SHALL <br />BE PAINTED TO MATCH THE ADJACENT WALL FINISH. <br />15. UNDERSIDE OF SOFFITS (WHERE OCCURS) TO BE PAINTED PT-1. <br />16. ALL WALLS TO RECEIVE PT-1 AND B-1 U.N.O. <br />17. ALL FLOORING THROUGHOUT TO REMAIN EXPOSED CONCRETE_, U.N.O. <br />18. FINISH FLOORING TO EXTEND FROM WALL TO WALL INCLUDING UNDER <br />CABINETS AND UNDER CABINET EQUIPMENT. <br />19. ALL INTERIOR WALL AND CEILING FINISHES TO COMPLY WITH IBC SECTION <br />803 AND IBC TABLE 803.9 AND ALL LOCAL CODE AMENDMENTS. <br />20. ALL INTERIOR FLOOR FINISHES TO COMPLY WITH IBC SECTION 804 AND ALL <br />LOCAL CODE AMENDMENTS. <br />21. ALL DECORATIVE MATERIALS AND TRIM SHALL COMPLY WITH IBC SECTION 805 <br />AND ALL LOCAL CODE AMENDMENTS. <br />22. ALL PAINTED SURFACES ARE TO RECEIVE A PRIME COAT AND A MINIMUM OF <br />TWO COATS FINAL COLOR, U.N.O. APPLY PER MANUFACTURER'S <br />RECOMMENDATION. <br />23. ALL PAINTED DOORS AND DOOR FRAMES SHALL BE PAINTED WITH AN ALKYD <br />BASED SEMI -GLOSS FINISH U.N.O. <br />24. ALL CONVECTOR COVERS SHALL BE PAINTED WITH AN ALKYD BASED <br />SEMI -GLOSS FINISH U.N.O. <br />25. CARPET CONTRACTOR SHALL VERIFY THAT ALL CARPET OF EACH VARIETY IS <br />TO BE SHIPPED FROM THE SAME DYE -LOT. <br />26. ALL WALLS PAINTED WITH A LATEX PAINT TO HAVE AN EGGSHELL FINISH, <br />U.N.O. REFER TO THE FINISH SCHEDULE AND FINISH LEGEND. <br />27. GYPSUM BOARD CEILINGS SCHEDULED TO RECEIVE PAINT SHALL HAVE A FLAT <br />FINISH, U.N.O. <br />28. PROVIDE DESIGNER WITH A MINIMUM OF (3) 8" X 10" BRUSH -OUTS OF EACH <br />COLOR AND FINISH FOR DESIGNER'S APPROVAL. PRIOR TO APPLICATION, <br />ON -SITE APPLICATION WILL BE REQUIRED FOR FINAL APPROVAL. DESIGNER <br />RESERVES THE RIGHT TO ADJUST ANY COLOR/FINISH ONCE THE WALL TEST <br />HAS BEEN MADE. <br />29. PRIOR TO THE INSTALLATION OF ANY CARPET MATERIAL, PROVIDE TO THE <br />DESIGNER, FOR APPROVAL, A SEAMING DIAGRAM ILLUSTRATING THE <br />DIRECTION OF THE CARPET AND THE SEAM LOCATIONS. <br />30. CARPET SEAMS SHALL NOT BE LOCATED PERPENDICULAR THROUGH DOOR <br />THRESHOLDS <br />31. ALL PLASTIC LAMINATE MILLWORK ENCLOSED CABINET INTERIORS TO BE <br />WHITE MELAMINE, U.N.O. <br />32, ARCHITECTURAL ADHESIVES, SEALANTS AND SEALANT PRIMERS MUST COMPLY <br />WITH SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE <br />#1168. VOLATILE ORGANIC COMPOUND (VOC) LIMITS LISTED IN THE TABLE <br />BELOW CORRESPOND TO RULE AMENDMENT DATE OF JANUARY 7, 2005. <br />33. PAINTS AND COATINGS : APPLIED TO INTERIOR WALLS AND CEILINGS MUST <br />NOT EXCEED THE VOLATILE ORGANIC COMPOUND (VOC) CONTENT LIMITS <br />ESTABLISHED IN GREEN SEAL STANDARD GS-11, PAINTS, EDITION 3.2, <br />OCTOBER 26, 2015. <br />34. ANTI -CORROSIVE AND ANTI -RUST PAINTS; APPLIED TO INTERIOR FERROUS <br />METAL SUBSTRATES MUST NOT EXCEED THE VOC CONTENT LIMIT OF 250 G/L <br />ESTABLISHED IN GREEN SEAL STANDARD GC-03, ANTI -CORROSIVE PAINTS, <br />2ND EDITION, JANUARY 7, 1997. <br />35, CLEAR WOOD FINISHES, FLOOR COATINGS, STAINS, PRIMERS, SEALERS, AND <br />SHELLACS: APPLIED TO INTERIOR ELEMENTS MUST NOT EXCEED THE VOC <br />CONTENT LIMITS ESTABLISHED FOR THOSE COATING TYPES IN SOUTH COAST <br />AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE 1113, ARCHITECTURAL <br />COATINGS, AMENDED FEBRUARY 5, 2016. <br />Crested Crane I nteiriors <br />Design Studio <br />23410 18th Ave. South, Suite <br />Des Moines, WA 98198 <br />WWW.CRESTEDCRANEINTERIORS.COM <br />Client &Tenant: <br />Designer: <br />g <br />Project Location'. <br />OLYMPIC HOT TUB <br />811 SE TT MALL WAY, SUITE <br />EVERETT, <br />Description: Date: o.. <br />PERMIT SET 02/15/2021 <br />NEW ENTRY DOOR REVISION <br />`Join <br />a T E <br />A H3TOT/ <br />A <br />#; �� n <br />:< AWAM E :LL <br />; TAT O W��51pt14I j 'T <br />#m <br />FINISH PLAN <br />03/16/2021 1 I \ <br />rJ, .: T- TT <br />, ME <br />