10/24/2017 10:16:28 AM <br />THE FOLLOWING NOTES APPLY EXCEPT WHERE SHOWN OTHERWISE <br />CODE: INTERNATIONAL BUILDING CODE IBC (2015) <br />STRUCTURALLOADS <br />EARTHQUAKE LOADS: SEISMIC RISK CATEGORY: II <br />SEISMIC IMPORTANCE FACTOR, le = 1.00 <br />MAPPED ACCELERATIONS, Ss m 1.44, 31 = 0.56 <br />SITE CLASS = D <br />DESIGN ACCELERATIONS, Sds = 0.96 Shc = 0.56 <br />SEISMIC DESIGN CATEGORY: D <br />SHOP DRAWINGS <br />SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW PRIOR TO FABRICATION. SHOP DRAWING SUBMITTALS PROCESSED BY <br />THE ENGINEER ARE NOT CHANGE ORDERS. THE PURPOSE OF SHOP DRAWING SUBMITTALS BY THE CONTRACTOR IS TO <br />DEMONSTRATE TO THE ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN CONCEPT, BY INDICATING WHICH <br />MATERIAL IS INTENDED TO BE FURNISHED AND INSTALLED, AND BY DETAILING THE INTENDED FABRICATION AND <br />INSTALLATION METHODS. IF DEVIATIONS, DISCREPANCIES, OR CONFLICTS BETWEEN SHOP DRAWING SUBMITTALS AND THE <br />CONTRACT DOCUMENTS ARE DISCOVERED EITHER PRIOR TO OR AFTER SHOP DRAWING SUBMITTALS ARE PROCESSED BY <br />THE ENGINEER, THE DESIGN DRAWINGS AND SPECIFICATIONS SHALL CONTROL AND SHALL BE FOLLOWED. SUBMITTAL <br />REVIEW IS FOR GENERAL CONFORMANCE ONLY; THIS REVIEW DOES NOT CHECK DIMENSIONS OR QUANTITIES. <br />FOUNDATIONS <br />MAXIMUM SOIL PRESSURE OF 1500 PSF FOR BUILDING FOUNDATION. ALL FOOTINGS TO BEAR WELL PREPARED SUB -GRADE <br />PER GEOTECH REPORT, SURFACE SOILS AND SHALL BE LOWERED IF SUITABLE SOIL IS NOT FOUND AT ELEVATIONS SHOWN ON <br />DRAWINGS. BACKFILL TO BE THOROUGHLY COMPACTED PER SPECIFICATIONS. EXTERIOR FOOTINGS SHALL BEAR 1'41(MIN) <br />BELOW FINISH GRADE. <br />11 ' = - <br />A. CONCRETE <br />ALL CAST -IN -PLACE CONCRETE SHALL BE WITH THE EXPOSURE CATEGORIES, WATER -CEMENT RATIOS, ENTRAINED AIR AND <br />MINIMUM 26-DAY COMPRESSIVE STRENGTHS AS INDICATED IN THE CONCRETE SCHEDULE ON THIS SHEET. <br />ELEMENTS <br />EXPOSURE CATEGORY WIC AIR <br />fC <br />FOUNDATION <br />FO <br />SO <br />CO <br />3000 <br />FOUNDATION WALLS <br />FO <br />SO <br />CO <br />3000 <br />FOUNDATION WALLS ABOVE GRADE <br />F1 <br />SO <br />C1 0.55 5.5 <br />3000 <br />SLAB ON GRADE <br />FO <br />SO <br />CO <br />3000 <br />SLAB ON GRADE EXPOSED TO WEATHER <br />F2 <br />SO <br />C2 0.4 7 <br />3000 <br />CONCRETE MIX DESIGNS FOR ALL CONCRETE ELEMENTS SHALL COMPLY WITH SECTION 19.3 OF ACI 316-14 BASED ON THE <br />EXPOSURE CATEGORIES LISTED IN THE ABOVE TABLE. NO CALCIUM CHLORIDE SHALL BE USED IN ANY CONCRETE. <br />B. REINFORCING <br />ALL REINFORCING BARS SHALL BE NEW BILLET STEEL ASTM A615, GRADE 60 CONFIRMING TO ACI 316 SECTION 20.2.2.5. <br />WELDABLE REINFORCING BARS SHALL CONFIRM TO ASTM A706. <br />EPDXY COATED BARS, WHERE INDICATED ON PLAN, SHALL CONFORM TO ASTM A775. <br />ALL WELDED WIRE REINFORCEMENT (WWR) SHALL CONFORM TO ASTM A165. <br />EPDXY COATED WWR SHALL CONFORM TO ASTM A634, CLASS A. <br />ALL HEADED SHEAR STUD REINFORCEMENT SHALL CONFORM TO ASTM A1044. <br />ALL CONCRETE REINFORCEMENT SHALL BE DETAILED, FABRICATED, LABELED, SUPPORTED, SPACED IN FORMS, AND SECURED <br />IN PLACE IN ACCORDANCE WITH THE PROCEDURES AND REQUIREMENTS OUTLINED IN THE LATEST EDITION OF ACI 316, AND <br />THE "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES", ACI 315. <br />THE CONTRACTOR SHALL SUBMIT CHECKED SHOP DRAWINGS SHOWING REINFORCING DETAILS, INCLUDING STEEL SIZES, <br />SPACING, PLACEMENT AND SUPPORT DETAILS AND DOWELS AT EXPANSION JOINTS FOR REVIEW PRIOR TO FABRICATION. <br />ALL REINFORCING SPLICES SHALL CONFORM TO THE REQUIREMENTS OF LATEST EDITION OF ACI 316 AND THE SPLICE TABLE <br />INCLUDED IN THE STRUCTURAL DOCUMENTS UNO. ALL WWR SHALL BE LAPPED TWO (2) FULL MESH PANELS AND TIED <br />SECURELY. <br />WHERE REQUIRED, DOWELS SHALL MATCH THE SIZE AND SPACING OF MAIN REINFORCING, UNO. <br />ALL MECHANICAL, PLUMBING AND ELECTRICAL EQUIPMENT PADS SHALL BE REINFORCED WITH AT LEAST ONE (1) LAYER OF <br />6X6-W4.0 X W4.0 WWR AT TOP CONTINUOUS, UNO. SEE HVAC, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL <br />REINFORCING REQUIREMENTS FOR PADS. <br />BAR SUPPORTS IN CONTACT WITH EXPOSED SURFACES SHALL BE PLASTIC TIPPED. <br />IN NON -PRESTRESSED CAST -IN -PLACE CONCRETE, THE SPECIFIED CONCRETE COVER FOR REINFORCEMENT SHALL NOT BE <br />LESS THAN THE FOLLOWING, UNLESS LARGER COVER IS NOTED ELSEWHERE. <br />® CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3 IN. <br />® CONCRETE EXPOSED TO EARTH OR WEATHER: #6 THROUGH #16 BARS 2 IN. <br />® CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: <br />SLABS, WALLS, JOISTS: #14 AND #16 BARS 1-1/2 IN. <br />#11 BAR AND SMALLER 3/4 IN. <br />BEAMS, COLUMNS: REINFORCEMENT, TIES, STIRRUPS, SPIRALS 1-1/2 IN. <br />PROVIDE #4 HAIRPIN BARS WITH 12" LEGS AT 6" O.C. (MINIMUM) AT HEAD OF ALL OPENINGS WITH 245 BARS EXTENDING <br />30" BEYOND OPENING AT HEAD. PROVIDE (2) #5 EXTRA BARS EXTENDING 30" (MINIMUM) BEYOND CORNERS AT TOP, <br />BOTTOM, AND EACH SIDE OF OPENINGS. USE (2) #5 X 4'-0" DIAGONALS AT EACH CORNER OF OPENINGS EXCEPT FOR 6" <br />WALLS. USE (1) 5X4'O" DIAGONAL AT EACH CORNER IN 6" WALLS. <br />USE #4 RAISER BARS FOR ALL SLABS. WHERE SLAB STEEL IS PARALLEL TO A BEAM OR WALL PROVIDE #4 X 50" AT 12"OC <br />IN TOP OF SLAB ACROSS BEAM OR WALL. WHERE SLAB IS ON ONE SIDE ONLY, TOP ELBOW BARS SHALL BE #4 X 3'-0' <br />AT 12" O.C. AT OPENINGS UNDER 16" SQUARE PROVIDE 2 BARS SAME SIZE AS MAIN STEEL EXTENDING 32 DIAMETERS PAST <br />OPENING, AT EACH SIDE AND DIAGONALLY AT CORNERS. <br />C. CONSTRUCTION JOINTS <br />CONSTRUCTION JOINTS IN ALL WALLS, ELEVATED SLABS AND BEAMS SHALL NOT BE FURTHER APART THAN 60 FEET IN ANY <br />DIRECTION. <br />ALL CONSTRUCTION JOINTS SHALL BE ROUGHENED TO A MAGNITUDE OF 3/4" AND SHALL BE WIRE BRUSHED, CLEANED AND <br />MOISTENED IMMEDIATELY PRIOR TO PLACING NEW CONCRETE. <br />PLACE ALL SLABS -ON -GRADE IN STRIP POURS OF 30 FEET MAXIMUM WIDTH WITH A MINIMUM OF 24 HOURS BETWEEN <br />ADJACENT POURS. STRIP POURED SLABS SHALL HAVE SAW CUT CONTROL JOINTS SPACED AT 36 TIMES THE SLAB <br />THICKNESS (15'4' MAXIMUM) ON CENTER. SAW CUTTING SHOULD BE PERFORMED BEFORE THE CONCRETE STARTS TO <br />COOL AFTER PEAK <br />HEAT OF CEMENT HYDRATION, AND AS SOON AS THE CONCRETE HAS HARDENED ENOUGH TO SUPPORT EQUIPMENT WITHOUT <br />DAMAGE AND NOT RAVEL THE CONCRETE DURING CUTTING. SAW CUTTING SHALL BE DONE WITHIN 12 HOURS OF CONCRETE <br />PLACEMENT. <br />ALLOW A MINIMUM OF 24 HOURS BETWEEN PLACEMENT OF CONCRETE FOR COLUMNS, WALLS OR PIERS AND PLACEMENT OF <br />CONCRETE ON THE ADJACENT FLOOR. <br />D. CURING AND SEALING <br />PROVIDE SPECIFIED CURING COMPOUND AND SEALER FOR THE TOP SURFACE OF ALL SLAB WORK, UNLESS NOTED OTHERWISE. <br />VERIFY COMPATIBILITY OF SPECIFIED SEALERS AND/OR HARDENERS WITH ARCHITECTURAL TOPPINGS AND FINISHES. <br />E. TOLERANCES <br />ALL CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI 117, LATEST EDITION, "SPECIFICATIONS FOR <br />TOLERANCES FOR CONCRETE CONSTRUCTION AND MATERIALS AND COMMENTARY", EXCEPT AS MODIFIED BY THESE <br />DOCUMENTS. <br />SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR TYPE AND LOCATION OF ALL FLOOR FINISHES, FLOOR <br />DEPRESSIONS, AND NONSTRUCTURAL CURBS. <br />SLABS SHALL MEET THE FLOOR FLATNESS (FF) AND FLOOR LEVELNESS (FL) TOLERANCES INDICATED IN SPECIFICATIONS. <br />FINISHED FLOOR SLABS THAT DO NOT MEET THE SPECIFIED SURFACE TOLERANCES SHALL BE REPAIRED AT THE <br />CONTRACTOR'S EXPENSE. CONTRACTOR TO SUBMIT PROPOSED REPAIff PROCEDURES TO THE ARCHITECT/STRUCTURAL <br />ENGINEER FOR REVIEW AND APPROVAL PRIOREXECUTION OF REPAIR WORK. <br />F. CONDUITS AND PIPES EMBEDDED IN CONCRETE <br />CONDUITS, PIPES, AND SLEEVES OF ANY MATERIAL NOT HARMFUL TO CONCRETE AND WITHIN THE LIMITATIONS OF SECTION <br />6.3 OF ACI 316 (LATEST EDITION) SHALL BE PERMITTED TO BE EMBEDDED IN CONCRETE, ONLY WITH PRIOR WRITTEN <br />APPROVAL OF THE ARCHITECT/STRUCTURAL ENGINEER. THE CONTRACTOR SHALL SUBMIT DETAILED DIMENSIONED AND <br />COORDINATED DRAWINGS OF PROPOSED EMBEDDED CONDUIT, PIPES, AND SLEEVES TO THE ARCHITECT PRIOR TO <br />CONSTRUCTION. <br />CONDUITS AND PIPES OF ALUMINUM SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE UNLESS EFFECTIVELY COATED OR <br />COVERED TO PREVENT ALUM IN UM -CONCRETE REACTION OR ELECTROLYTIC ACTION BETWEEN ALUMINUM AND STEEL. <br />CONDUITS, PIPES, AND SLEEVES PASSING THROUGH A SLAB, WALL, OR BEAM SHALL NOT IMPAIR SIGNIFICANTLY THE <br />STRENGTH OF THE CONSTRUCTION. <br />CONDUITS AND PIPES EMBEDDED WITHIN A SLAB, WALL, OR BEAM (OTHER THAN THOSE MERELY PASSING THROUGH) SHALL <br />SATISFY THE FOLLOWING. <br />a. THEY SHALL NOT BE LARGER IN OUTSIDE DIAMETER THAN 1/3RD THE OVERALL THICKNESS OF THE SLAB, WALL, OR <br />BEAM IN WHICH THEY ARE EMBEDDED; <br />b. THEY SHALL NOT BE SPACED CLOSER THAN 3 DIAMETERS OR WIDTHS; <br />C. THEY SHALL NOT SIGNIFICANTLY IMPAIR THE STRENGTH OF THE CONSTRUCTION. <br />PIPES AND FITTINGS SHALL BE DESIGNED TO RESIST EFFECTS OF THE MATERIAL, PRESSURE, AND TEMPERATURE TO <br />NO LIQUID, GAS, OR VAPOR, EXCEPT WATER NOT EXCEEDING 90 DEGREES FAHRENHEIT NOR 50 PSI PRESSURE, SHALL BE <br />PLACED IN EMBEDDED PIPES UNTIL THE SURROUNDING CONCRETE HAS ATTAINED ITS FULL DESIGN STRENGTH, <br />IN SOLID SLABS, PIPING, UNLESS IT IS FOR RADIANT HEATING OR SNOW MELTING, SHALL BE PLACED BETWEEN THE TOP <br />AND BOTTOM REINFORCEMENT. <br />CONCRETE COVER FOR PIPES, CONDUIT, AND THEIR FITTINGS SHALL NOT BE LESS THAN 1-1/2 INCH FOR CONCRETE <br />EXPOSED TO EARTH OR WEATHER AND NOT LESS THAN 3/4 INCH FOR CONCRETE NOT EXPOSED TO WEATHER OR IN <br />CONTACT WITH GROUND. <br />ADDITIONAL REINFORCEMENT WITH AN AREA NOT LESS THAN 0.002 TIMES THE GROSS AREA OF THE CONCRETE SECTION AT <br />A SPACING NOT EXCEEDING 12 INCHES SHALL BE PROVIDED PERPENDICULAR TO THE PIPING. <br />PIPING AND CONDUIT SHALL BE SO FABRICATED AND INSTALLED THAT CUTTING, BENDING, OR DISPLACEMENT OF <br />REINFORCEMENT FROM ITS PROPER LOCATION WILL NOT BE REQUIRED. #5 BAR, W31, OR D31 WIRE AND SMALLER 1-1/2 IN. <br />G. GENERAL <br />THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS SHOWING THE LOCATIONS OF ALL CONSTRUCTION JOINTS, CONTROL JOINTS, <br />CURBS, SLAB DEPRESSIONS, SLEEVES, OPENINGS, ETC. <br />CONCRETE SLABS AND WALLS SHALL NOT BE SLEEVED OR BOXED -OUT OR HAVE THE REINFORCING INTERRUPTED, EXCEPT AS <br />INDICATED ON THE STRUCTURAL DRAWINGS. ADDITIONAL SLEEVES OR BOX -OUTS MAY BE REQUIRED FOR ARCHITECTURAL, <br />HVAC, <br />ELECTRICAL, OR MECHANICAL ELEMENTS. A COORDINATED COMPOSITE DRAWING INDICATING ALL SLEEVES AND BOX -OUTS <br />REQUIRED FOR THE WORK OF ALL DISCIPLINES SHALL BE SUBMITTED TO THE ARCHITECT/STRUCTURAL ENGINEER FOR <br />APPROVAL PRIOR TO CONSTRUCTION. A COMPOSITE DRAWING SHALL BE SUBMITTED FOR EACH SLAB AND/OR WALL AND THE <br />SIZE AND DIMENSIONED LOCATION OF ALL SLEEVES, BOX -OUTS, CORES, ETC. SHALL BE INDICATED. <br />CONCRETE BEAMS SHALL NOT BE SLEEVED OR BOXED -OUT OR HAVE THE REINFORCING INTERRUPTED, EXCEPT AS <br />INDICATED ON THE STRUCTURAL DRAWINGS. <br />MINIMUM SLAB -ON -GRADE THICKNESSES SHALL BE 5" FOR SIDEWALKS, 6" FOR AUTOMOBILE TRAFFIC AREAS, AND 10" FOR <br />TRUCK TRAFFIC AREAS, UNO. <br />ANCHORAGE TO HARDENED CONCRETE: <br />WERE EXPANSION ANCHORS ARE SPECIFIED, USE "HILTI KWIK BOLT TZ" (REFERENCE ICC REPORT ESR-1917.) <br />WERE SCREW ANCHORS ARE SPECIFIED, USE "SIMPSON TITEN HD" (REFERENCE ICC REPORT ESR-2713). <br />WERE EPDXY ANCHORS ARE SPECIFIED, USE "HILTI HY-200" OR "SIMPSON SET-XP" (REFERENCE ICC REPORT ESR-3167 <br />AND ESR-2506). <br />"HILTI HIT -RE 500", AND "SIMPSON SET" MAY NOT BE USED, UNLESS SPECIFICALLY PRE -APPROVED BY THE STRUCTURAL <br />ENGINEER. <br />FOR EPDXY ANCHORS, USE ASTM A193 GRADE B7 THREADED ROD, UNLESS OTHERWISE NOTED. HOLES MUST BE CLEANED <br />OF DUST AND DEBRIS AND BE FREE OF STANDING WATER WHEN EPDXY IS INSTALLED. SPECIAL INSPECTION OF EPDXY <br />ANCHORS IS REQUIRED. DO NOT CUT ANY REINFORCING BARS TO INSTALL ANCHORS. DEFECTIVE HOLES SHALL BE FILLED <br />SOLID WITH EPDXY. <br />FOR ANY SUBSTITUTIONS TO THE ABOVE, THE CONTRACTOR SHALL SUBMIT TO THE STRUCTURAL ENGINEER MANUFACTURER'S <br />LITERATURE DESCRIBING THE ANCHORS AND LISTING ICC APPROVED ALLOWABLE SHEAR AND TENSION VALUES. <br />SCOPE OF STRUCTURAL ENGINEERING SERVICES: <br />THE STRUCTURAL ENGINEER HAS PERFORMED THE STRUCTURAL DESIGN AND PREPARED THE STRUCTURAL WORKING DRAWINGS <br />FOR THIS PROJECT. THE CONSTRUCTION MUST BE PERFORMED IN STRICT ACCORDANCE WITH THE STRUCTURAL DRAWINGS. ANY <br />DEVIATION FROM THE DRAWINGS MUST BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER. ERRORS AND/OR OMISSIONS <br />FOUND ON THE STRUCTURAL DRAWINGS MUST BE BROUGHT TO THE STRUCTURAL ENGINEER'S ATTENTION IMMEDIATELY. <br />ARCHITECTURAL DRAWINGS ARE THE PRIME CONTRACT DRAWINGS. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION <br />WITH ARCHITECTURAL DRAWINGS. PRIMARY STRUCTURAL ELEMENTS ARE DIMENSIONED ON THE STRUCTURAL PLANS AND DETAILS. <br />THE GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE DIMENSIONS AMONG ALL DRAWINGS. ANY DISCREPANCIES, <br />CONTRADICTIONS, OR OMISSIONS SHALL BE REPORTED TO THE ARCHITECT FOR RESOLUTION PRIOR TO PROCEEDING WITH WORK <br />OR FABRICATION OF THE ITEM(S) IN QUESTION. <br />THE STRUCTURAL ENGINEER IS RESPONSIBLE FOR THE DESIGN OF THE PRIMARY STRUCTURAL SYSTEM, EXCEPT FOR ANY <br />COMPONENTS NOTED ABOVE. RESPONSIBILITY FOR ANY SECONDARY STRUCTURAL AND NON-STRUCTURAL SYSTEMS NOT SHOWN <br />ON THE STRUCTURAL PLANS RESTS WITH SOMEONE OTHER THAN THE STRUCTURAL ENGINEER, <br />THE STRUCTURE SHOWN ON THESE DRAWINGS IS STRUCTURALLY SOUND ONLY IN ITS COMPLETED FORM. THE CONTRACTOR <br />SHALL PROVIDE ALL NECESSARY BRACING TO STABILIZE THE BUILDING DURING CONSTRUCTION. <br />THE STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR, AND WILL NOT HAVE CONTROL OF, CONSTRUCTION MEANS, METHODS, <br />TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE <br />CONSTRUCTION WORK, NOR WILL HE BE RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO CARRY OUT THE CONSTRUCTION <br />WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, <br />FIELD MEASUREMENTS AND THE VERIFICATION OF FIELD DIMENSIONS ARE NOT PART OF THE STRUCTURAL ENGINEER'S <br />RESPONSIBILITY. THE CONTRACTOR MUST CHECK ALL (ASSUMED) EXISTING CONDITIONS SHOWN ON THESE DRAWINGS FOR <br />ACCURACY AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES. <br />OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS OR THE INADVERTENT MISLABELING OF DETAILS OF WORK WHICH ARE <br />MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH ARE CUSTOMARILY <br />PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR INADVERTENT MISLABELED DETAILS <br />OF THE WORK BUT THEY SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN THE DRAWINGS AND <br />SPECIFICATIONS. <br />DEFERRED SUBMITTALS: <br />THE FOLLOWING ITEMS ARE CONSIDERED TO BE DEFERRED SUBMITTALS UNDER SECTION 107.3.4.1 OF THE INTERNATIONAL <br />BUILDING CODE AND MUST BE SUBMITTED TO THE ARCHITECT OR THE ENGINEER FOR REVIEW. SUBMITTALS TO INCLUDE FULL, <br />DETAILED DESIGN, DRAWINGS, AND CALCULATIONS SIGNED BY A PROFESSIONAL ENGINEER IN THE STATE WHERE THE PROJECT <br />IS LOCATED. DESIGNS SIGNED BY AN ENGINEER WHO IS NOT LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED WILL BE <br />REJECTED WITHOUT REVIEW, THESE ITEMS WILL THEN BE FORWARDED TO THE BUILDING OFFICIAL FOR APPROVAL. THE <br />DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN ADD SUBMITTAL DOCUMENTS HAVE BEEN <br />APPROVED BY THE BUILDING OFFICIAL. <br />® METAL BUILDING <br />REV <br />DATE <br />REV 0 <br />2017-09-25 <br />REV 1 <br />2017-10-25 <br />Aim)) S Y S T E M S <br />2201 100TH ST. SW <br />Stamp: <br />Drawing Title: <br />JOB #: 17FO35 <br />Drawing No: <br />PERMIT SET <br />