Laserfiche WebLink
/24/2017 10:16:32 AM <br />REQUIRED INSPECTIONS, VERIFICATION AND TESTS OF SOILS <br />TYPE <br />CONTINUOUS <br />PERIODIC <br />REFERENCE STANDARD <br />IBC REFERENCE <br />VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE <br />X <br />ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY <br />VERIFY EXCAVATIONS ARE EXTENDED TO PROPER <br />X <br />DEPTH AND HAVE REACHED PROPER MATERIAL <br />PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS <br />X <br />VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESS <br />X <br />DURING PLACEMENT AND COMPACTION OF COMPACTED FILL <br />PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT SUBGRADE AND <br />X <br />VERIFY THAT SITE HAS BEEN PREPARED PROPERLY <br />REQUIRED INSPECTIONS, VERIFICATION AND TESTS OF CONCRETE CONSTRUCTION <br />TYPE <br />CONTINUOUS <br />PERIODIC <br />REFERENCE STANDARD <br />IBC REFERENCE <br />INSPECT REINFORCEMENT AND VERIFY PLACEMENT <br />X <br />ACI 313 Ch. 20, 25.2, <br />1906.4 <br />25.3, 26.6.1-26.6.3 <br />REINFORCING BAR WELDING: <br />a. VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN ASTM A706 <br />X <br />AWS D1.4 <br />B. INSPECT SINGLE -PASS FILLET WELDS, MAXIMUM 5/16"; AND <br />X <br />ACI 313: 26.6.4 <br />C. INSPECT ALL OTHER WELDS <br />X <br />INSPECT ANCHORS CAST IN CONCRETE <br />X <br />ACI 316:17.8.2 <br />INSPECT ANCHORS POST -INSTALLED IN HARDEDNED CONCRETE MEMBERS (B) <br />A. ADHESIVE ANCHORS INSTALLED HORIZONTALLY OR UPWARDLY <br />X <br />ACI 316: 17.8.2.4 <br />INCLINED ORIENTAIONS TO RESIST SUSTAINED TENSION LOADS <br />B. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN (A) <br />X <br />ACI 313: 17.6.2 <br />VERIFY USE OF REQURED DESIGN MIX (F'C > 2500 PSI) <br />X <br />ACI 318: Ch. 19, <br />1904.1, 1904.2, <br />26.4.3, 26.4.4 <br />1903.2, 1906.3 <br />PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH <br />ASTM C172 <br />TESTS, PREFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE <br />X <br />ASTM C31 <br />1908.10 <br />TEMPERATURE OF THE CONCRETE <br />ACI 313: 26.4, 26.12 <br />INSPECT CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER <br />X <br />ACI 313: 26.5 <br />1903.6,1906.7, <br />APPLICATION TECHNIQUES <br />1903.3 <br />VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES <br />ACI 318: 26.5.3-26.5.5 <br />1906.9 <br />INSPECT FORMWORK FOR SHAPE, LOCATION AND <br />X <br />ACI 316: 26.11.1.2(b) <br />DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED <br />NONSTRUCTURAL SLABS ON GRADE <br />NOT REQUIRED <br />NOT REQUIRED <br />1704.2.5 <br />REV <br />DATE <br />REV 0 <br />2017-09-25 <br />REV 1 <br />2017-10-25 <br />000\\ <br />oo\ <br />H PEl ),R Ml C . <br />D SYSTEMS <br />WAREHOUSE <br />EXPANSION <br />2201 100TH ST. SW <br />Stamp: <br />Drawing Title: <br />JOB #: 17FO35 <br />Drawing No: <br />PERMIT SET <br />