Laserfiche WebLink
WINDOW SCHEDULE - MAIN FLOOR <br />SYM. NO. <br />I WIDTH <br />I HEIGHT <br />AREA <br />WINDOW TYPE <br />U-VALUE <br />COMMENTS <br />MAIN FLOOR <br />2 <br />6'- 0" <br />5'- 0" <br />30 SF <br />SLIDER <br />0.30 <br />4 <br />5'- 0" <br />4'- 6" <br />23 SF <br />SLIDER <br />0.30 <br />5 <br />6'- 0" <br />5'- 0" <br />30 SF <br />SLIDER <br />0.30 <br />6 <br />11'- 6" <br />1 8' - 0" <br />12 SF <br />PICTURE (FIXED) <br />0.30 <br />TEMP. GL. <br />22 <br />16'- 0" <br />11'- 3" <br />18 SF <br />PICTURE (FIXED) <br />10.30 <br />Grand total 102 SF <br />DOOR SCHEDULE - MAIN FLOOR <br />SYM. NO. <br />WIDTH <br />HEIGHT <br />DOOR TYPE <br />COMMENTS <br />MAIN FLOOR <br />D1 <br />12' - 0" <br />8'- 0" <br />Door 4-Panel_Stacking_Patio Door <br />TEMP. GLASS (U=0.30) <br />D2 <br />2' - 6" <br />8'- 0" <br />SINGLE PANEL <br />D3 <br />3' - 6" <br />8'- 0" <br />Single -Glass Simpson modern <br />TEMP. GLASS (U=0.30) <br />D4 <br />5'- 0" <br />8' - 0" <br />DOUBLE PANEL <br />D5 <br />2' - 8" <br />8' - 0" <br />SINGLE PANEL <br />D6 <br />6' - 0" <br />8'- 0" <br />BI-PASS CLOSET DOOR <br />D7 <br />2' - 6" <br />8'- 0" <br />SINGLE PANEL <br />D8 <br />16'- 0" <br />8' - 0" <br />OVERHEAD GARAGE DOOR <br />INSULATED STEEL OVERHEAD GARAGE DOOR <br />D10 <br />2' - 8" <br />8'- 0" <br />SINGLE PANEL <br />1 3/8" SOLID CORE w/ SELF CLOSING MECHANISM <br />KEYNOTE SCHELDULE <br />KEY VALUE TEXT <br />01 <br />GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE DOOR OR EQUIV. 20 MIN. RATED FIRE RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A SELF -CLOSING <br />DEVICE. (R302.5.1) <br />02 <br />LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN THE TOP OF THE <br />THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) <br />03 <br />GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR EQUIV. IS REQUIRED BETWEEN <br />THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 & TABLE 302.6) <br />04 <br />COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS. RANGE HOOD SHALL HAVE <br />LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT <br />EQUIV. TO THE EXHAUST RATE. (M1503) <br />05 <br />CRAWLSPACE OPENING: MIN. 18"x24" THROUGH THE FLOOR OR MIN. 16"x24" THROUGH THE PERIMETER WALL. (R408.4) <br />06 <br />GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR <br />GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4" SPHERE CANNOT PASS THROUGH. (R312) <br />07 <br />STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. <br />DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN, TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8". FIREBLOCK <br />STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM <br />(311.7.6) <br />08 <br />EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA <br />IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. (R310.1) <br />09 <br />DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SHALL BE INSTALLED PER MANUFACTURER SPECS. AND IN STRICT ACCORDANCE W/ LOCAL BUILDING CODES. MUST BE U.L. <br />LISTED. (M1303/ G2427.2.1) <br />10 <br />DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER <br />TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502) <br />11 <br />TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. <br />GWB AT INSIDE FACE w/ P.V.A. PRIMER. <br />12 <br />PILOTS, BURNERS, & SWITCHES TO BE 18" MIN: ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE WALLS OR CEILINGS <br />SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE. WATER HEATERS SHALL BE ANCHORED AGAINST <br />MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE PLUMBED TO OUTSIDE. <br />13 <br />FUEL FIRED APPLIANCES: WHERE THE VOLUME OF THE SPACE IN WHICH THE APPLIANCE IS LOCATED IS GREATER THAN 50 CU. FT. PER 1000 BTU/H THEN NO VENTILATION IS <br />REQUIRED. IF LESS, PROVIDE VENTILATION IN ACCORDANCE WITH G2407.5. <br />14 <br />ATTIC ACCESS: MIN. 22"X30" AND REQUIRED AT AREAS GREATER THAN 30 SQ. FT. AND VERTICAL HEIGHT OF 30" OR GREATER. (R807.1) SEE M1305.1.3 FOR ADDITIONAL <br />REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTIC. <br />17 <br />CLOSET ROD w/ VINYL COATED WIRE SHELF <br />19 <br />TEMP. GLASS DOOR <br />20 <br />TEMP. GLASS WINDOW <br />21 <br />TUB/SHOWER: ONE PIECE ACRYLIC OR FIBERGLASS WITH CURTAIN OR TEMP. GLASS DOOR PER OWNER SPECS. <br />23 <br />FIBERGLASS SHOWER PAN OR EQUIV. w/ TILE SURROUND AND TEMP. GLASS SHOWER DOOR. <br />24 <br />FIBERGLASS TUB w/ TILE SURROUND AND CURTAIN OR TEMP. GLASS DOOR PER BUILDER SPECIFCATIONS. <br />25 <br />PANTRY SHELVING: PROVIDE (5) MELAMINE OR EQUIV. 16" DEEP SHELVES PER BUILDER SPECIFICATIONS. <br />26 <br />TEMPERED GLASS SHOWER DOOR AND ENCLOSURE. <br />27 <br />1/2" GWB UNDER STAIRWAY IN ENCLOSED SPACES. <br />C D E <br />48' - 0" <br />37' 0„ <br />)r 5'- 5 1/2" 10' 0" 12' - 7" 8'- 11 1/2" <br />MAIN <br />F <br />OPTIONAL <br />VENTLESS GAS FIREPLACE C <br />IN NON-STRUCTRURAL WOOD <br />FRAME. <br />FLOOR <br />0 <br />CV <br />0 <br />U <br />Z <br />co <br />co <br />c) <br />Q <br />7 U <br />CL <br />Y = m <br />0 <br />J '} N <br />SOU <br />M 0 <br />Z <br />to <br />W N <br />Lu <br />r <br />t�C <br />o E <br />-a <br />m <br />0 <br />Lu <br />a <br />ZN N c .00 'O N c C WO C O O <br />N a-,, <br />m C O <br />Q.9 <br />00 J c o o <br />U u_ a .. <br />p <br />Q W W O O U G U p >,N a C 3 N ro O O <br />UJ_- N_" N rl <br />O O U O C_ Q ... 'O <br />JAG a0 aQty O <br />= O m o o E a <br />Z <br />W <br />z <br />Lu <br />(y) <br />0 <br />N <br />00 <br />ad <br />Q <br />I— <br />w <br />W LL <br />Lu <br />0 <br />1 <br />,_,_, <br />Q <br />N <br />LL1 <br />ry <br />a o <br />00 <br />Q � <br />Z (y) <br />a� <br />m <br />0 <br />c <br />0 <br />L <br />N <br />a <br />z <br />PROJECT NO. <br />200202 <br />DESIGNED BY <br />TL <br />DRAWN BY <br />TL & RM <br />CHECKED BY <br />TL <br />SHEET NO. <br />A5 <br />PRINT DATE 9/23/2020 8:16:57 AM <br />