My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3618 SHORE AVE 2020 Plans 2022-12-01
>
Address Records
>
SHORE AVE
>
3618
>
Plans
>
3618 SHORE AVE 2020 Plans 2022-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 11:10:21 AM
Creation date
4/21/2022 3:49:33 PM
Metadata
Fields
Template:
Address Document
Street Name
SHORE AVE
Street Number
3618
Permit
C2010-002
Year
2020
Notes
CONSTRUCT NEW SFR WITH GARAGE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WINDOW SCHEDULE - MAIN FLOOR <br />SYM. NO. <br />I WIDTH <br />I HEIGHT <br />AREA <br />WINDOW TYPE <br />U-VALUE <br />COMMENTS <br />MAIN FLOOR <br />2 <br />6'- 0" <br />5'- 0" <br />30 SF <br />SLIDER <br />0.30 <br />4 <br />5'- 0" <br />4'- 6" <br />23 SF <br />SLIDER <br />0.30 <br />5 <br />6'- 0" <br />5'- 0" <br />30 SF <br />SLIDER <br />0.30 <br />6 <br />11'- 6" <br />1 8' - 0" <br />12 SF <br />PICTURE (FIXED) <br />0.30 <br />TEMP. GL. <br />22 <br />16'- 0" <br />11'- 3" <br />18 SF <br />PICTURE (FIXED) <br />10.30 <br />Grand total 102 SF <br />DOOR SCHEDULE - MAIN FLOOR <br />SYM. NO. <br />WIDTH <br />HEIGHT <br />DOOR TYPE <br />COMMENTS <br />MAIN FLOOR <br />D1 <br />12' - 0" <br />8'- 0" <br />Door 4-Panel_Stacking_Patio Door <br />TEMP. GLASS (U=0.30) <br />D2 <br />2' - 6" <br />8'- 0" <br />SINGLE PANEL <br />D3 <br />3' - 6" <br />8'- 0" <br />Single -Glass Simpson modern <br />TEMP. GLASS (U=0.30) <br />D4 <br />5'- 0" <br />8' - 0" <br />DOUBLE PANEL <br />D5 <br />2' - 8" <br />8' - 0" <br />SINGLE PANEL <br />D6 <br />6' - 0" <br />8'- 0" <br />BI-PASS CLOSET DOOR <br />D7 <br />2' - 6" <br />8'- 0" <br />SINGLE PANEL <br />D8 <br />16'- 0" <br />8' - 0" <br />OVERHEAD GARAGE DOOR <br />INSULATED STEEL OVERHEAD GARAGE DOOR <br />D10 <br />2' - 8" <br />8'- 0" <br />SINGLE PANEL <br />1 3/8" SOLID CORE w/ SELF CLOSING MECHANISM <br />KEYNOTE SCHELDULE <br />KEY VALUE TEXT <br />01 <br />GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE DOOR OR EQUIV. 20 MIN. RATED FIRE RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A SELF -CLOSING <br />DEVICE. (R302.5.1) <br />02 <br />LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN THE TOP OF THE <br />THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) <br />03 <br />GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR EQUIV. IS REQUIRED BETWEEN <br />THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 & TABLE 302.6) <br />04 <br />COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS. RANGE HOOD SHALL HAVE <br />LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT <br />EQUIV. TO THE EXHAUST RATE. (M1503) <br />05 <br />CRAWLSPACE OPENING: MIN. 18"x24" THROUGH THE FLOOR OR MIN. 16"x24" THROUGH THE PERIMETER WALL. (R408.4) <br />06 <br />GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR <br />GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4" SPHERE CANNOT PASS THROUGH. (R312) <br />07 <br />STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. <br />DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN, TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8". FIREBLOCK <br />STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM <br />(311.7.6) <br />08 <br />EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA <br />IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. (R310.1) <br />09 <br />DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SHALL BE INSTALLED PER MANUFACTURER SPECS. AND IN STRICT ACCORDANCE W/ LOCAL BUILDING CODES. MUST BE U.L. <br />LISTED. (M1303/ G2427.2.1) <br />10 <br />DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS. DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER <br />TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502) <br />11 <br />TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. <br />GWB AT INSIDE FACE w/ P.V.A. PRIMER. <br />12 <br />PILOTS, BURNERS, & SWITCHES TO BE 18" MIN: ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE WALLS OR CEILINGS <br />SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE. WATER HEATERS SHALL BE ANCHORED AGAINST <br />MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE PLUMBED TO OUTSIDE. <br />13 <br />FUEL FIRED APPLIANCES: WHERE THE VOLUME OF THE SPACE IN WHICH THE APPLIANCE IS LOCATED IS GREATER THAN 50 CU. FT. PER 1000 BTU/H THEN NO VENTILATION IS <br />REQUIRED. IF LESS, PROVIDE VENTILATION IN ACCORDANCE WITH G2407.5. <br />14 <br />ATTIC ACCESS: MIN. 22"X30" AND REQUIRED AT AREAS GREATER THAN 30 SQ. FT. AND VERTICAL HEIGHT OF 30" OR GREATER. (R807.1) SEE M1305.1.3 FOR ADDITIONAL <br />REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTIC. <br />17 <br />CLOSET ROD w/ VINYL COATED WIRE SHELF <br />19 <br />TEMP. GLASS DOOR <br />20 <br />TEMP. GLASS WINDOW <br />21 <br />TUB/SHOWER: ONE PIECE ACRYLIC OR FIBERGLASS WITH CURTAIN OR TEMP. GLASS DOOR PER OWNER SPECS. <br />23 <br />FIBERGLASS SHOWER PAN OR EQUIV. w/ TILE SURROUND AND TEMP. GLASS SHOWER DOOR. <br />24 <br />FIBERGLASS TUB w/ TILE SURROUND AND CURTAIN OR TEMP. GLASS DOOR PER BUILDER SPECIFCATIONS. <br />25 <br />PANTRY SHELVING: PROVIDE (5) MELAMINE OR EQUIV. 16" DEEP SHELVES PER BUILDER SPECIFICATIONS. <br />26 <br />TEMPERED GLASS SHOWER DOOR AND ENCLOSURE. <br />27 <br />1/2" GWB UNDER STAIRWAY IN ENCLOSED SPACES. <br />C D E <br />48' - 0" <br />37' 0„ <br />)r 5'- 5 1/2" 10' 0" 12' - 7" 8'- 11 1/2" <br />MAIN <br />F <br />OPTIONAL <br />VENTLESS GAS FIREPLACE C <br />IN NON-STRUCTRURAL WOOD <br />FRAME. <br />FLOOR <br />0 <br />CV <br />0 <br />U <br />Z <br />co <br />co <br />c) <br />Q <br />7 U <br />CL <br />Y = m <br />0 <br />J '} N <br />SOU <br />M 0 <br />Z <br />to <br />W N <br />Lu <br />r <br />t�C <br />o E <br />-a <br />m <br />0 <br />Lu <br />a <br />ZN N c .00 'O N c C WO C O O <br />N a-,, <br />m C O <br />Q.9 <br />00 J c o o <br />U u_ a .. <br />p <br />Q W W O O U G U p >,N a C 3 N ro O O <br />UJ_- N_" N rl <br />O O U O C_ Q ... 'O <br />JAG a0 aQty O <br />= O m o o E a <br />Z <br />W <br />z <br />Lu <br />(y) <br />0 <br />N <br />00 <br />ad <br />Q <br />I— <br />w <br />W LL <br />Lu <br />0 <br />1 <br />,_,_, <br />Q <br />N <br />LL1 <br />ry <br />a o <br />00 <br />Q � <br />Z (y) <br />a� <br />m <br />0 <br />c <br />0 <br />L <br />N <br />a <br />z <br />PROJECT NO. <br />200202 <br />DESIGNED BY <br />TL <br />DRAWN BY <br />TL & RM <br />CHECKED BY <br />TL <br />SHEET NO. <br />A5 <br />PRINT DATE 9/23/2020 8:16:57 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.