Laserfiche WebLink
WINDOW SCHEDULE - 2ND FLOOR <br />SYM. N6 <br />WIDTH <br />HEIGHT <br />AREA <br />WINDOW TYPE <br />U-VALUE <br />COMMENTS <br />2ND FLOOR <br />19 <br />T - 0" <br />4'- 0" <br />28 SF <br />DOUBLE SLIDER <br />0.30 <br />TEMP. GL <br />20 <br />8'- 0" <br />4'- 0" <br />32 SF <br />DOUBLE SLIDER <br />0.30 <br />8 <br />6'- 0" <br />4'- 0" <br />24 SF <br />SLIDER <br />0.30 <br />9 <br />8' - 0" <br />5' - 0" <br />40 SF <br />DOUBLE SLIDER <br />0.30 <br />10 <br />6'- 0" <br />4'- 6" <br />27 SF <br />SLIDER <br />0.30 <br />12 <br />2' - 0" <br />3' - 0" <br />6 SF <br />SINGLE HUNG <br />0.30 <br />TEMP. GL <br />13 <br />2' - 0" <br />3' - 0" <br />6 SF <br />SINGLE HUNG <br />0,30 <br />TEMP: GL <br />14 <br />2' - 0" <br />2' - 0" <br />4 SF <br />PICTURE (FIXED) <br />0.30 <br />15 <br />2' - 0" <br />2' - 0" <br />4 SF <br />PICTURE (FIXED) <br />0.30 <br />16 <br />2' - 0" <br />2' - 0" <br />4 SF <br />PICTURE (FIXED) <br />0.30 <br />17 <br />2' - 0" <br />2' - 0" <br />4 SF <br />PICTURE (FIXED) <br />0.30 <br />18 <br />2' - 0" <br />2' - 0" <br />4 SF <br />PICTURE (FIXED) <br />0.30 <br />21 <br />9' - 0" <br />21- 6" <br />23 SF <br />DOUBLE SLIDER <br />0.30 <br />25 18'- <br />0" <br />1' - 3" <br />110SF <br />PICTURE (FIXED) <br />0.30 <br />Grand total 216 SF <br />DOOR SCHEDULE - 2ND FLOOR <br />SYM. NO. <br />WIDTH <br />HEIGHT <br />DOOR TYPE <br />COMMENTS <br />2ND FLOOR <br />D12 <br />2' - 6" <br />6'- 8" <br />SINGLE PANEL <br />D13 <br />2' - 6" <br />6' - 8" <br />SINGLE PANEL <br />D14 <br />5' - 0" <br />6'- 8" <br />DOUBLE PANEL <br />D15 <br />2' - 6" <br />6'- 8" <br />SINGLE PANEL <br />D16 <br />2' - 6" <br />6'- 8" <br />SINGLE PANEL <br />1 3/8" SOLID CORE w/ SELF CLOSING MECHANISM <br />D17 <br />2' - 6" <br />6'- 8" <br />SINGLE PANEL <br />D18 <br />2' - 6" <br />6'- 8" <br />SINGLE PANEL <br />D19 <br />2' - 6" <br />6'- 8" <br />SINGLE PANEL <br />D20 <br />2' - 6" <br />6'- 8" <br />SINGLE PANEL <br />D21 <br />2' - 6" <br />6' - 8" <br />SINGLE PANEL <br />D22 <br />2' - 6" <br />6'- 8" <br />SINGLE PANEL <br />D23 <br />2' - 8" <br />6'- 8" <br />SINGLE PANEL <br />D24 <br />2' - 8" <br />6'- 8" <br />SINGLE PANEL <br />D25 <br />2' - 4" <br />6'- 8" <br />SINGLE PANEL <br />D26 <br />12'- 6" <br />16'- 8" <br />1 SINGLE PANEL <br />KEYNOTE SCHELDULE <br />KEY VALUE TEXT <br />01 <br />GARAGE DOOR: PROVIDE 1 3/8" SOLID CORE DOOR OR EQUIV. 20 MIN. RATED FIRE RATED DOOR BETWEEN HOUSE AND GARAGE. DOOR TO BE EQUIPPED WITH A SELF -CLOSING <br />DEVICE. (R302.5.1) <br />02 <br />LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5" LOWER THAN THE TOP OF THE <br />THRESHOLD; 7 3/4" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING. MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) <br />03 <br />GARAGE WALL: SEPARATION FROM GARAGE AND RESIDENCE SHALL HAVE 1/2" GYPSUM BOARD APPLIED TO GARAGE SIDE. A 5/8" TYPE "X" GWB OR EQUIV. IS REQUIRED BETWEEN <br />THE GARAGE AND HABITABLE SPACE ABOVE THE GARAGE. (R302.6 & TABLE 302.6) <br />04 <br />COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUF. SPECS. RANGE HOOD SHALL HAVE <br />LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT <br />EQUIV. TO THE EXHAUST RATE. (M1503) <br />05 <br />CRAWLSPACE OPENING: MIN. 18"x24" THROUGH THE FLOOR OR MIN. 16"x24"THROUGH THE PERIMETER WALL. (R408.4) <br />06 <br />GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR <br />GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36" IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THAT A 4" SPHERE CANNOT PASS THROUGH. (R312) <br />07 <br />STAIR TREADS AND RISERS (R311.7): MAX. RISER HEIGHT SHALL BE 7 3/4". RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. <br />DIFFERENCE IN RISER HEIGHTS SHALL NOT EXCEED 3/8". THE MIN. TREAD DEPTH SHALL BE 10". DIFFERENCE IN TREAD DEPTH SHALL NOT BE GREATER THAN 3/8". FIREBLOCK <br />STAIRS PER IRC 302.11. ALL STAIRS TO BE PROVIDED WITH A LIGHT AND SWITCH AT TOP AND BOTTOM OF STAIRS (R303.7). STAIR LANDINGS REQUIRED AT TOP AND BOTTOM <br />(311.7.6) <br />08 <br />EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS, BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA <br />IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. (R310.1) <br />09 <br />DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SHALL BE INSTALLED PER MANUFACTURER SPECS. AND IN STRICT ACCORDANCE W/ LOCAL BUILDING CODES. MUST BE U.L. <br />LISTED. (M1303/ G2427.2.1) <br />10 <br />DRYER: VENT TO OUTSIDE AND PER MANUFACTURER SPECICATIONS, DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH AND CONSTRUCTED OF METAL. MAX. DUCT LENGTH PER <br />TABLE M1502.4.4.1 OR M1502.4.4.2. (M1502) <br />11 <br />TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. <br />GWB AT INSIDE FACE w/ P.V.A. PRIMER. <br />12 <br />PILOTS, BURNERS, & SWITCHES TO BE 18" MIN. ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE WALLS OR CEILINGS <br />SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE. WATER HEATERS SHALL BE ANCHORED AGAINST <br />MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDE PRESSURE RELIEF LINE PLUMBED TO OUTSIDE. <br />13 <br />FUEL FIRED APPLIANCES: WHERE THE VOLUME OF THE SPACE IN WHICH THE APPLIANCE IS LOCATED IS GREATER THAN 50 CU. FT. PER 1000 BTU/H THEN NO VENTILATION IS <br />REQUIRED. IF LESS, PROVIDE VENTILATION IN ACCORDANCE WITH G2407.5. <br />14 <br />ATTIC ACCESS: MIN. 22"X30" AND REQUIRED AT AREAS GREATER THAN 30 SQ. FT. AND VERTICAL HEIGHT OF 30" OR GREATER. (R807.1) SEE M1305.1.3 FOR ADDITIONAL <br />REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTIC. <br />17 <br />CLOSET ROD w/ VINYL COATED WIRE SHELF <br />19 <br />TEMP. GLASS DOOR <br />20 <br />TEMP. GLASS WINDOW <br />21 <br />TUB/SHOWER: ONE PIECE ACRYLIC OR FIBERGLASS WITH CURTAIN OR TEMP. GLASS DOOR PER OWNER SPECS, <br />23 <br />FIBERGLASS SHOWER PAN OR EQUIV. w/ TILE SURROUND AND TEMP. GLASS SHOWER DOOR. <br />24 <br />FIBERGLASS TUB w/ TILE SURROUND AND CURTAIN OR TEMP. GLASS DOOR PER BUILDER SPECIFCATIONS. <br />25 <br />PANTRY SHELVING: PROVIDE (5) MELAMINE OR EQUIV. 16" DEEP SHELVES PER BUILDER SPECIFICATIONS. <br />26 <br />TEMPERED GLASS SHOWER DOOR AND ENCLOSURE. <br />27 <br />1/2" GWB UNDER STAIRWAY IN ENCLOSED SPACES. <br />2ND FLOOR <br />V <br />Z <br />N <br />0 <br />W <br />Z <br />p <br />Q <br />Y2 m <br />U � <br />J <br />u <br />'o <br />ern@) <br />CM CO 2 <br />z <br />5.9 <br />W N <br />W <br />e! W <br />GC <br />o <br />W <br />m <br />--a <br />0 <br />LLJ <br />a <br />k <br />0 <br />�t <br />r , <br />Nf <br />o ° <br />O C O 9 E N C C Q O <br />.Nc= <br />cram c�w,otl-�o�LUc <br />=2Q ao-�OV sc= 8' <br />O O J ° N C U 0. �° t Vl � <br />aw� IEa�y�o°-��om�d°�`�Oo <br />p w V o B o U o c 3 G-w <br />I we O�����U 0N��p=tea <br />Za�u°im Nm�0FEwa`� <br />uj <br />Lu <br />• <br />LIJ <br />0 <br />C14 <br />Lu <br />w <br />00 <br />1-0 <br />PROJECT NO. <br />III <br />200202 <br />DESIGNED BY <br />TL <br />DRAWN BY <br />TL & RM <br />CHECKED BY <br />TL <br />SHEET NO. <br />A6 <br />PRINT DATE 9/23/2020 8:18:37 AM <br />