My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1322 RUCKER AVE 2021 Plans 2022-10-27
>
Address Records
>
RUCKER AVE
>
1322
>
Plans
>
1322 RUCKER AVE 2021 Plans 2022-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2022 2:12:26 PM
Creation date
4/21/2022 4:22:40 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
1322
Permit
B2107-065
Year
2021
Notes
ADDITION OF A MASTER SUITE BEDROOM AND BATHROOM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IF THIS PLAN IS NOT ON 22x34 PAPER IT HAS BEEN SCALED ACCORDINGLY <br />Attic area venting <br />calculation: <br />Total NEW Attic Area in sgft: 374.00 <br />Required Area of Venting: 3S9.04 <br />/ 150 <br />sgin <br />V600 (20.00sgin/if): 6 If <br />IN -Vent (6.75sgin/If: 16 if <br />RS400 (18.75sgin/ea: 16 ea <br />120 <br />108 <br />300 <br />sgin <br />sgin <br />sgin <br />Total Proposed Venting Area: <br />sgin <br />528 > <br />�►U W 1 LTQ4 t-_b J0" ®, L <br />PLAN <br />NORTH <br />PLAN <br />NORTH <br />1 I ROOF PLAN SCAUL 1/�t =1 -0° 1 2 I ROOF FRAMING PLAN SCALE: 1/4"=T-0" <br />FIELD LOCATE 1601Sn <br />SOLATUBE IN W.I.C. <br />O <br />i� <br />N <br />Plan Legend: <br />--a Existing 2x wall framing to be removed <br />Existing 2x wall framing to remain <br />c New 2x wall framing <br />�S 110v Smoke Alarm with Battery Backup <br />© 110v Carbon Monoxide Alarm with Battery Backup <br />® Ceiling Ventilation Fan <br />Fuel Gas shutoff (Flame Safeguard) <br />Window Type, Reference Schedules Plan <br />Door Type, Reference Schedules Plan <br />TSG Tempered Safety Glass <br />OX Structural hardware per Hardware Schedule <br />XX Shearwall per schedule <br />5'-9" <br />COMPRESSOR <br />SLAB LOCATION <br />3 <br />-2. <br />17'-0" <br />8'-31/2" —� 2'-11%2" <br />8'-2" <br />CS14/MS C4863 <br />203' SH _ 1 <br />TSG ^-- <br />BATH <br />VINYL LAM <br />42"x36" SHWR � ! �� <br />O 80Cf I' <br />80Cfm d <br />FN/LT <br />1 HT/FN/LT 1 O5 <br />3°68 PKT <br />3o6s <br />Wu <br />1 � 3068 <br />3' ' 3N" <br />M. SUITE <br />HARDWOOD O <br />101 r <br />.1 <br />h <br />N <br />0� <br />1 <br />>,,� <br />it <br />(e) KITCHEN <br />HARDWOOD <br />30"x22" ATTIC ACCESS <br />L e LIVING <br />IVING <br />HARDWOOD <br />- DN CS14/MSTC48B3 <br />-2" 9'-6" — <br />1T-0" <br />(e) DECK L' <br />COMPOSITE -- --- -- <br />N <br />3 1 FLOOR PLAN SCALE:1/4"=V-0" 1 4 <br />1, .-)3/. <br />HUCQ612 - <br />4 <br />0 <br />00 <br />FLOOR FRAMING PLAN <br />15'-9y4" <br />------E-X . 48 <br />FLOOR IS DESIGNED TO BE AN <br />UNVENTED ASSEMBLY <br />36`0x4'-3" DEEP CONC. FTG. <br />w/ WET SET P.T. 6x6 HF#1 <br />t POST (HOLD 3" OFF BOTTOM <br />OF FTG.) w/ CCQ/ECCQ66-SDS2.5 <br />@ TOP (TYP/PLACES) <br />Q <br />Ln <br />2x12 HF#2 LEDGER w/ <br />1/4"x4l/z" SDS SCREWS @ <br />7"o.c. (STAGGERED) <br />IUS1.81/11.88 (U210 @ ALT) (TYP) <br />PLAN <br />NORTH <br />SCALE: 1/4"=T-0" <br />V " <br />Q 0"n <br />Ro <br />co <br />1. <br />V) <br />w � <br />Ln <br />V ) - <br />< � <br />�^ <br />Cd <br />- <br />w <br />a <br />Z <br />lD <br />D <br />00 <br />s <br />g <br />C <br />®¢ <br />� <br />N <br />o <br />N <br />n. <br />W � <br />.eC a <br />9 <br />to <br />m <br />W � <br />� <br />� <br />J <br />.� <br />N <br />N C <br />C <br />pO1 <br />G CO O <br />C <br />cn W <br />g, m <br />a <br />^2b <br />S <br />O <br />m w a w <br />w <br />0 <br />u <br />c <br />0 <br />t <br />� <br />V <br />•c <br />= <br />N <br />a� <br />Cr <br />o <br />M <br />N <br />cM <br />J <br />< <br />tnn <br />-F-� <br />LU <br />0 <br />rm <br />> <br />a <br />w <br />C <br />O <br />p <br />O <br />m <br />Plan Title <br />Floor Plans <br />Drawn <br />Douglas Almond <br />Date <br />07/13/2021 <br />rojec o. <br />21-043-01 <br />Plan Revisions <br />10 08/11/2021 <br />0 - <br />o - <br />o - <br />sheet: <br />04 <br />Of.. — <br />
The URL can be used to link to this page
Your browser does not support the video tag.