5319 SOUND AVE 2020 Plans 2022-11-30
>
Address Records
>
SOUND AVE
>
5319
>
Plans
>
5319 SOUND AVE 2020 Plans 2022-11-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 2:28:52 PM
Creation date
4/22/2022 3:46:53 PM
Metadata
Fields
Template:
Address Document
Street Name
SOUND AVE
Street Number
5319
Permit
B2004-039
Year
2020
Notes
SECOND FLOOR ADDN / REPLACE ROOF AT NORTH PORTION OF HOUSE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5'-113/4"+/- <br />15'- 5 3/4" + / - <br />11' - 6112" <br />co <br />CD <br />B <br />(E) GOING PATIO, <br />NO CHANGE - <br />V <br />3 <br />A3.2 <br />A3.0 <br />------------------- - --� <br />I j <br />- 2 <br />---- - - - - -- -------- - - - - - <br />� <br />I El I <br />I I I <br />I I I I <br />13'-7" I <br />5'- 3 1/2" 2' -1 EQ EQ <br />I I <br />� N002 N001 I f 02 ARESS <br />� I <br />--- ---- <br />tj <br />I I <br />FURRED-OU I WD <br />I <br />FRAMING OVER (E) 2X4 <br />' I WALL ON TOP OF <br />CONC CURB, MIN R-21 02C 1 <br />INSUL, TYP BETWEEN <br />W001 GRIDLINE A AND B I _ <br />i SG _ _ BEDROOM <br />_ _ 02 <br />C13162 SF <br />I E002 I <br />I I <br />I SG 01 <br />I <br />1 BONUS <br />-Al <br />A3.2 I <br />-1-1SD <br />I <br />I <br />I <br />377 SF <br />I <br />I <br />CLG HEIGHT: <br />APPROX 7'4 <br />02A 03 <br />I <br />III <br />I <br />(NO CHANGE) <br />I <br />3 A3.1 <br />I <br />(E) GONG RETAINING <br />(E) GONG RETAINING I <br />STAIRCASE ABV <br />I <br />- <br />WALL, NO CHANGE <br />WALL, NO CHANGE <br />SHOWN DASHED <br />TYP WD HANDRAIL, <br />I <br />1 <br />SEE DETAIL 13/A3.3 <br />BATH <br />03 <br />I <br />_ <br />E001 <br />I <br />I <br />w � <br />3'-4"CLR <br />o 70SF <br />SIG <br />I <br />g' <br />I <br />_ <br />-' <br />036 <br />n <br />3 - 2 <br />-- <br />ALIGN <br />FRAMING <br />W/ FACE OF HALL <br />- <br />I I III <br />POST® 04 <br />- - <br />1 <br />117 SF <br />A3.2 <br />I <br />I <br />EQ <br />EQ <br />- <br />- <br />13 RISERS @ 7 5/18"EACH, <br />c� a <br />- <br />11 TREAD W/1" <br />(A1_0 1 NOSING, PER R311.7, <br />I I I -I <br />05 <br />HANDRAIL PER R311.7.8 <br />-- <br />06 <br />I- <br />-� RELOC TED <br />0'0! <br />WATER HEATER W/ MIN <br />FURN E <br />ALIGN FRAMING W/ <br />- - <br />- <br />EFFICIENCY OF 0.91 <br />-! I ! ! I <br />FACE OF (E) WD POST <br />- <br />- <br />1=-- <br />-- -- <br />- - <br />- .-- CLG HEIGHT: <br />PLAY ROOM <br />APPROX 7'6 <br />05 <br />I <br />I = <br />- _ (NO CHANGE) <br />151 SF <br />! <br />- <br />* NOT TO BE USED AS <br />- - - L <br />A DWELLING UNIT <br />UTILITY/STORAGE <br />I- <br />2 <br />�- <br />! - 349 SF <br />! <br />05A 058 <br />1 <br />`� <br />- -- <br />R-5 CONT RIGID INSUL <br />OVER (E) GONG WALL, W/I- <br />I i! MIN R-13 FURRED OUT <br />CAVITY WALL, TYP @ <br />1 <br />-- <br />-- <br />- BELOW GRADE WALLS <br />9! I= I 1= I I- 11 i! I==1 <br />1 i I I- <br />i I I i =1 I i!----� <br />-; i <br />LW= <br />1/4" = V-0" <br />0 2 a s <br />WINDOW SCHEDULE <br />MARK <br />WIDTH <br />HEIGHT <br />HEAD <br />HEIGHT <br />MAX <br />U-VALUE <br />OPERATION <br />COMMENTS <br />E001 <br />1' -11 1/2" <br />1' - 81/2" <br />6'- 8" <br />0.30 <br />AWNING <br />SAFETY GLAZING PER R308.4, VISION <br />GLASS <br />E002 <br />5'- 81/2" <br />1' - 81/2" <br />6 - 8" <br />0.30 <br />SLIDER - UNEQUAL <br />E101 <br />5'- 111/2" <br />3- 51/2" <br />7'- 0" <br />0.30 <br />SLIDER - UNEQUAL <br />E102 ' <br />5'- 21/2" <br />3'- 5 1/2" <br />7'- 0" <br />0.30 <br />SLIDER - UNEQUAL <br />El 03 <br />5'- 21/2" <br />3' - 51/2" <br />7' - 0" <br />0.30 <br />SLIDER - UNEQUAL <br />E201 <br />1' - 81/2" <br />3'- 51/2" <br />7' - 0" <br />0.30 <br />CASEMENT <br />E202 <br />7'- 11 1/2" <br />1 1' - 81/2" <br />7'- 0" <br />0.30 <br />SLIDER -UNEQUAL <br />N001 <br />4'- 111/2" <br />V - 81/2" <br />6' - 8" <br />0.30 <br />FIXED <br />N002 <br />4' -11 1/2" <br />T - 81/2" <br />6'- 8" <br />0.30 <br />SLIDER - UNEQUAL <br />N101 <br />7'- 111/2" <br />3'- 51/2" <br />1 7'- 0" <br />0.30 <br />FIXED <br />N102 <br />1' - 81/2" <br />3- 51/2" <br />7'- 0" <br />0.30 <br />CASEMENT <br />SAFETY GLAZING PER R308.4 <br />N103 <br />1' - 81/2" <br />5'- 111/2" <br />7'- 0" <br />0.30 <br />CASEMENT <br />SAFETY GLAZING PER R308.4_ <br />N104 <br />3'- 2112" <br />5' -11 1/2" <br />7' - 0" <br />0.30 <br />FIXED <br />SAFETY GLAZING PER R308.4 <br />N201 <br />1' - 81/2" <br />5'- 11 1/2" <br />7' - 0" <br />0.30 <br />CASEMENT <br />N202 <br />3'- 21/2" <br />5' -11 1/2" <br />7'- 0" <br />0.30 <br />FIXED <br />R210 <br />4'- 31/8" <br />4'- 31/8" <br />0.50 <br />FIXED <br />SKYLIGHT, VELUX FCM4646 OR SIM, <br />SAFETY GLAZING PER R308.6 <br />R230 <br />2'- 3 1/8" <br />4'- 31/8" <br />0.50 <br />FIXED <br />SKYLIGHT, VELUX FCM2246 OR SIM, <br />SAFETY GLAZING PER R308.6 <br />R240 <br />2'- 31/8" <br />4'- 3 1/8" <br />0.50 <br />FIXED <br />SKYLIGHT, VELUX FCM2246 OR SIM, <br />SAFETY GLAZING PER R308.6 <br />5101 <br />1 5'- 8 1/2" <br />1' - 81/2" <br />7'- 0" <br />1 0.30 <br />SLIDER - UNEQUAL <br />S201 <br />4' -11 1/2" <br />1' - 81/2" <br />7'- 0" <br />0.30 <br />SLIDER - UNEQUAL <br />SAFETY GLAZING PER R308.4, VISION <br />GLASS <br />W001 <br />1' - 8 1/2" <br />5'- 11 1/2" <br />6' - 8" <br />0.30 <br />CASEMENT <br />SAFETY GLAZING PER R308.4 <br />W101 <br />4' -11 1/2" <br />5'- 11 1/2" <br />7'- 0" <br />0.30 <br />FIXED <br />SAFETY GLAZING PER R308.4 <br />W102 <br />T - 81/2" <br />5' -11 1/2" <br />7'- 0" <br />0.30 <br />FIXED <br />W103 <br />4' -11 1/2" <br />5'- 11 1/2" <br />7'- 0" <br />0.30 <br />FIXED <br />SAFETY GLAZING PER R308.4 <br />W104 <br />V - 81/2" <br />5'- 111/2" <br />7'- 0" <br />0.30 <br />CASEMENT <br />1111105 <br />1' - 81 /2" <br />2'- 21/2" <br />7'- 0" <br />0.30 <br />FIXED <br />W106 <br />1' - 81/2" <br />3'- 8 1/2" <br />4'- 9 1/4" <br />0.30 <br />FIXED <br />SAF TY G AZI �G P R R 08.4 <br />W107 <br />V - 81/2" <br />2'- 21/2" <br />7'- 0" <br />0.30 <br />CASEMENT <br />SAFETY GLAZING PER R308.4, VISION <br />GLASS <br />W108 <br />1' - 81/2" <br />5'- 11 1/2" <br />7' - 0" <br />0.30 <br />CASEMENT <br />W201 <br />4' -11 1/2" <br />5' -11 1/2" <br />7' - 0" <br />0.30 <br />FIXED <br />W202 <br />1' - 81/2" <br />5' -11 1/2" 1 <br />7'- 0" <br />0.30 <br />CASEMENT <br />W203 <br />2'- 111/2" <br />5'- 111/2" <br />7'- 0" <br />0.30 <br />FIXED <br />SAFETY GLAZING PER R308.4 <br />W204 <br />1' - 81/2" <br />5' -11 1/2" <br />7'- 0" <br />0.30 <br />CASEMENT <br />W205 <br />1' - 8 1/2" <br />5'- 11 1/2" <br />7' - 0" <br />0.30 <br />CASEMENT <br />EXTERIOR DOOR SCHEDULE <br />MARK <br />t�llD T H <br />HEIGHT <br />MAX <br />U�VALUE <br />OPERATION <br />OOMM€NTS <br />01 <br />4'- 11 1/2" <br />6'- 7 1/2" <br />0.30 <br />SLIDING DOOR <br />SAFE GL IN PE R3 8.4 <br />02 <br />4'- 11 1/2" <br />6- 71/2" <br />0.30 <br />SLIDING DOOR <br />SAFETY GLAZING PER R308.4 <br />11 <br />4'- 11 1/2" <br />6'- 11 1/2" <br />0.30 <br />SLIDING DOOR <br />SAFETY GLAZING PER R308.4 <br />12 <br />4'- 11 1/2" <br />6'- 111/2" <br />0.30 <br />SLIDING DOOR <br />SAFETY GLAZING PER R308.4 <br />13 <br />2' -11 1/2" <br />6'- 111/2" <br />0.30 <br />SWING <br />FE GL I PE_ R' 8. <br />16 <br />2' -11 1/2" <br />6'- 71/2" <br />0,30 <br />SWING <br />MIN 1-3/8" SOLID WD DOOR, TO <br />COT LY / <br />21 <br />4' =11 1/2" <br />6'- 11 112" <br />0.30 <br />SLIDING DOOR <br />WPE3 <br />SAFETY GL ZIN 8.4 <br />22 <br />9' - 91/2" <br />6° -11 1/2" <br />0.30 <br />4-PANEL OXXO SLIDING <br />DOOR <br />Z SAFETY GLAZING PER R308.4 <br />INTERIOR DOOR SCHEDULE <br />DARK <br />WIDTH <br />HEIGHT <br />OPERATION <br />COMMENTS <br />02A <br />2'- 8' <br />6' - 8" <br />SWING <br />02B <br />5' - 0" <br />6'- 8" <br />BYPASS SLIDING DOOR <br />02C <br />5' - 0" <br />6' - 8" <br />BYPASS SLIDING DOOR <br />03 <br />2'- 8" <br />6'- 8" <br />SWING <br />03B <br />2` - 8" <br />6' - 8" <br />SWING <br />04 <br />2' - 8" <br />6' - 0" <br />SWING <br />05 <br />5'- 0" <br />6'- 8" <br />FRENCH DOOR <br />05A <br />5' - 0" <br />I 6' - 8" <br />FRENCH DOOR <br />05B <br />5' - 0" <br />6'- 81' <br />FRENCH DOOR <br />06 <br />3' - 0" <br />6'- 8" <br />SWING <br />13A <br />2'- 8" <br />7'- 0" <br />SWING <br />13B <br />3' - 0" <br />7'- 0" <br />SWING <br />- <br />14 <br />2'- 4" <br />7' - 0" <br />POCKET <br />15 <br />2'- 6" <br />7'- 0" <br />SWING <br />16A <br />3'- 0" <br />T - 0" <br />SWING <br />17 <br />2'-8" <br />7'-0" <br />SWING <br />17A <br />4'- 0" <br />7'- 0" <br />BYPASS SLIDING DOOR <br />17B <br />4' - 0" <br />- 7'- 0" <br />BYPASS SLIDING DOOR <br />18 <br />2'-8" <br />7'-0" <br />SWING <br />18A <br />4'- 0" <br />7' - 0" <br />BYPASS SLIDING DOOR <br />18B <br />4' - 0" <br />7'- 0" <br />BYPASS SLIDING DOOR <br />22A <br />2'- 8" <br />T - 0" <br />SWING <br />23 <br />4'- 0" <br />7'- 0" <br />DOUBLE POCKET <br />23A <br />2'- 4" <br />7' - 0" <br />POCKET <br />24 <br />2' - 8" <br />7'- 0" <br />POCKET <br />25 <br />2'- 8E: <br />7'- 0 <br />SWING <br />25A <br />2' - 8" <br />7' - 0" <br />SWING <br />WALL LEGEND <br />(E) WALL <br />WALL <br />SD <br />SMOKE DETECTOR <br />PER R314.1 <br />S/ <br />SMOKE AND CARBON <br />MONOXIDE ALARM PER <br />R314A AND R315.2 <br />FAN PER TABLE M1507.3.3 <br />CITY OF EVERETT <br />REVIEWED FOR PERMIT <br />APPROVAL STAMPS <br />An <br />H K S A R C H I I E C I S <br />1050 N.38th St <br />Seattle, VVA 98103 <br />PH: 206.675.9151 <br />mvw.shksarchitects.com <br />5158 REGISTERED f <br />. <br />_ ARCU`ITECT <br />JONATHAN �N. HAKU STATF OF t�ASHI'VGT064 <br />- AUG -FLOYU <br />RESIDENCE <br />-PERMIT <br />DRAWINGS <br />5319 Sound Ave. Everett, WA 98203 <br />Drawn by: JI <br />Checked: JH <br />Date: 06/05/20 <br />Scale: 1/4" = 1'-0" <br />- Revisions: <br />No. Date Remarks <br />1 06/05/20 PERMIT <br />CORRECTIONS 1 <br />BASEMENT <br />FLOOR PLAN <br />A200 <br />