5319 SOUND AVE 2020 Plans 2022-11-30
>
Address Records
>
SOUND AVE
>
5319
>
Plans
>
5319 SOUND AVE 2020 Plans 2022-11-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 2:28:52 PM
Creation date
4/22/2022 3:46:53 PM
Metadata
Fields
Template:
Address Document
Street Name
SOUND AVE
Street Number
5319
Permit
B2004-039
Year
2020
Notes
SECOND FLOOR ADDN / REPLACE ROOF AT NORTH PORTION OF HOUSE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 5'-113/4"+/- 15'-53/4 +/- - 11'-61/2 <br />3 <br />A3:2 <br />i <br />A3.0 <br />i <br />2 <br />Z <br />MEMBRANE ROOF, RIDGE OF SLOPED <br />1\ SLOPED TO DRAIN MEMBRANE ROOF, TYP <br />1/4" PER FT TYP <br />f <br />\ - - -- -- <br />WD DECKING OVER PT PRE -MANUFACTURED <br />WD SLEEPERS LIFTED GUARDRAIL, ALUM POST <br />ON PRE -MANUFACTURED 4' 0"' O.C. W/ STL CABLE, SURFACE - <br />SLEEPER PADS MTD TO T.O. SOLID PT WD <br />MAX RIM JOIST PERIMETER <br />GO 2 <br />A3.2 <br />'xx 3 A3.1 <br />a� 3„ <br />EQ EQ <br />--------- - - - - -- --- <br />I I <br />GUTTER BELOW, TYP I 11 7 <br />CA3.3 A3.3 <br />� N202 N201 21 22 ,/ � <br />UB <br />I TYP WDCED <br />I DN HANDRAIL, SEE <br />IWill DETAIL 13/A3.3 22A { <br />W201 <br />F 36" NIGH <br />FRAMED WALL <br />1 I GUARDRAIL, TYP <br />A3.2 I I -4c,1 { <br />M. BED { <br />SKYLIGHT ABV F22 I_ ® , <br />3'-- 4"CLR 5' - 2 3/4" 156 SF <br />T- 10" <br />{ HALL <br />6'-91/2" \ <br />STL COLUMN BELOW <br />3'- 2" 6' -1 1/2" <br />I I 25 2'- 11 1/2" <br />MIN 150 CFM WHOLE- <br />IN23 <br />HOUSE VENTILATION <br />' W203 FAN ON TIMER { <br />sG OFFICCQ <br />E <br />_ ID <br />F25-1C9 <br />I W204 91 SF <br />I O NOT TO BE USED AS <br />M. BATH <br />{ A DWELLING UNIT 25A 23AF 23 E201 I <br />136SF <br />I <br />I I <br />I ' M. CLOSET 24 r - - <br />- I f <br />132 SF I I M I <br />I <br />L - _ J - 6" <br />L - - - SKYLIGHT ABV " { <br />(E) GARAGE ROOF <br />I <br />BELOW { EQ EQ <br />ROOF OVERHANG ABV I 2X�6 WD FRAMING, S201 I < <br />SHOWN DASHED I TYP Cc? ALL NEW <br />EXTERIOR WALLS I SG I _ <br />L--'- -------------------- --- <br />EQ EQ1 <br />RAIN LEADER, TYP - <br />IN <br />�A3.1 <br />WINDOW <br />MARK <br />WIDTH <br />HEIGHT <br />HEAD <br />HEIGHT <br />MAX <br />U®VALUE <br />OPERATION <br />COMMENTS <br />E001 <br />V -11 1/2" <br />1'- 81/2" <br />6' - 8" <br />0.30 <br />AWNING <br />SAFETY GLAZING PER R308.4, VISION <br />GLASS <br />E002 <br />5' - 81/2" <br />1' - 81/2" <br />6' - 8" <br />0.30 <br />SLIDER - UNEQUAL <br />E101 <br />5' -11 1/2" <br />T- 51/2" <br />T- 0" <br />0.30 <br />SLIDER - UNEQUAL <br />E102 <br />5' - 21/2' <br />3- 51/2" <br />7' - 0" <br />0.30 <br />SLIDER - UNEQUAL <br />_E103 <br />5' - 21/2" <br />3' - 51/2" <br />T- 0" <br />0.30 <br />SLIDER - UNEQUAL <br />E201 <br />1'- 81/2" <br />3'- 51/2" <br />7' - 0" <br />0.30 <br />CASEMENT <br />E202 <br />T- 111/2" <br />1'- 81/2" <br />T- 0" <br />0.30 <br />SLIDER - UNEQUAL <br />N001 <br />4'- 111/2" <br />V - 81/2" <br />6- 8" <br />0.30 <br />FIXED <br />N002 <br />4'- 11 1/2" <br />V - 81/2" <br />6' - 8" <br />0.30 <br />SLIDER - UNEQUAL <br />N101 <br />T- 111/2" <br />3'- 51/2" <br />T- 0" <br />0.30 <br />FIXED <br />N102 <br />1'- 81/2' <br />3' - 51/2" <br />T - 0" <br />0.30 <br />CASEMENT <br />SAFETY GLAZING PER R308.4 <br />N103 <br />V - 81/2" <br />T- 111/2" <br />7'- 0" <br />-0.30 <br />CASEMENT <br />SAFETY GLAZING PER R308.4 <br />N104 <br />T- 21/2" <br />5' -11 1/2" <br />T - 0" <br />0.30 <br />FIXED <br />SAFETY GLAZING PER R308.4 <br />N201 <br />V - 81/2" <br />5' -11 1/2" <br />T- 0" <br />0.30 <br />CASEMENT <br />N202 <br />3'- 21/2" <br />5' -11 1/2" <br />T- 0" <br />0.30 <br />FIXED <br />R210 <br />4'- 3 1/8" <br />4'- 31/8" <br />0.50 <br />FIXED <br />SKYLIGHT, VELUX FCM4646 OR SIM, <br />SAFETY GLAZING PER R308.6 <br />R230 <br />2'- 31/6" <br />4'- 31/8" <br />0.50 <br />FIXED <br />SKYLIGHT; VELUX FCM2246 OR SIM <br />SAFETY GLAZING PER R308.6 <br />R240 <br />2'- 31/8" <br />4'- 31/8" <br />0.50 <br />FIXED <br />SKYLIGHT, VELUX FCM2246 OR SIM, <br />AF TY LAZ NG PER 13308 6 <br />S101 <br />5' - 81/2" <br />1'- 81/2" <br />7'- 0" <br />0.30 <br />SLIDER -UNEQUAL <br />S201 <br />T- 111/2" <br />V - 81/2" <br />7' - 0" <br />0.30 <br />SLIDER - UNEQUAL <br />SAFETY GLAZING PER R308.4, VISION <br />GLASS <br />W001 <br />1'- 81/2" <br />5' -11 1/2" <br />6' - 8" <br />0.30 <br />CASEMENT <br />SAFETY GLAZING PER R308.4 <br />W101 <br />T- 111/2" <br />5' -11 1/2" <br />T - 0" <br />0.30 <br />FIXED <br />SAFETY GLAZING PER R308.4 <br />W102 <br />V - 81/2" <br />5' -11 1/2" <br />T - 0" <br />0.30 <br />FIXED <br />W103 <br />4'- 11 1/2" <br />5' - 11 1/2" <br />T- 0" <br />0.30 <br />FIXED <br />SAFETY GLAZING PER R308.4 <br />W104 <br />1' - 81/2" <br />5' -11 1/2" <br />T- 0" <br />0.30 <br />CASEMENT <br />W105 <br />V - 81/2" <br />2'- 21/2" <br />7'- 0" <br />0.30 <br />FIXED <br />S L R 0 . <br />W106 <br />V _ 81/2" <br />T- 81/2` <br />4'- 91/4" <br />0.30 <br />FIXED _ <br />SAFE Imo( G AZI G P R R 08.4 <br />W107 <br />1'- 81/2" <br />2'- 21/2" <br />T- 0" <br />0.30 <br />CASEMENT <br />SAFETY GLAZING PER R308.4, VISION <br />GLASS <br />W108 <br />1' - 81/2" <br />T- 111/2" <br />T- 0" <br />0.30 <br />CASEMENT <br />W201 <br />T- 111/2" <br />T- 111/2" <br />T- 0" <br />0.30 <br />FIXED <br />W202 <br />1'- 81/2" <br />T- 111/2" <br />7'- 0" <br />0.30 <br />CASEMENT <br />W203 <br />2'- 11 1/2" <br />T- 111/2" <br />7' - 0" <br />0.30 <br />FIXED <br />SAFETY GLAZING PER R308.4 <br />W204 <br />1'- 81/2" <br />5' -11 1/2" <br />7'- 0" <br />0.30 <br />CASEMENT <br />W205 <br />V - 8 1/2" <br />T- 111/2" <br />7' - 0" <br />0.30 <br />CASEMENT <br />EXTERIOR DOOR SCHEDULE <br />MARK <br />WIDTH <br />HEIGHT <br />MAX <br />U-VALUE <br />OPERATION <br />COMMENTS <br />01 <br />4'- 11 1/2" <br />6' - 71/2" <br />0.30 <br />SLIDING DOOR <br />SAFETY GLA ING PER R30 .4 <br />02 <br />T- 11 1/2" <br />6'-_71/2" <br />0.30 <br />SLIDING DOOR <br />SAFETY GLAZING PER R308.4 <br />11 <br />4'- 11 1/2" <br />6' -11 1/2" <br />0.30 <br />SLIDING DOOR <br />SAFETY GLAZING PER R308.4 <br />12 <br />4'- 11 1/2" <br />6' -11 1/2" <br />0.30 <br />SLIDING DOOR <br />SAFETY GLAZING PER R308.4 <br />13 <br />2'- 11 1/2" <br />6' -11 1/2" <br />0.30 <br />SWING <br />SA ETY GL IN PE R30�.4 <br />16 <br />2'- 11 1/2" <br />6' - 7 1/2" <br />0.30 <br />SWING <br />MIN 1-3/8" SOLID WD DOOR, TO <br />OMPLY W R 02.5 <br />21 <br />4'- 111/2" <br />6' -11 1/2" <br />0.30 <br />_ <br />SLIDING DOOR <br />R308.4 <br />22 <br />9'- 91/2" <br />6'-11 1/2" <br />0.30 <br />4-PANEL OXXO SLIDING <br />DOOR <br />TET�'GLAZ]NdrPER <br />ZING PER R308.4 <br />INTERIOR <br />MARK <br />WIDTH <br />HEIGHT <br />OPERATION <br />COMMENTS <br />02A <br />2'- 8" <br />6' - 8" <br />SWING <br />028 <br />5' - 0" <br />6' - 8" <br />BYPASS SLIDING DOOR <br />02C <br />T - 0" <br />6- 8" <br />BYPASS SLIDING DOOR <br />-- <br />03 <br />2'- 8" <br />6' - 8" <br />SWING <br />03B <br />2' - 8" <br />6 - 8" <br />SWING <br />04 <br />2 - 8" <br />6' - 0" <br />SWING <br />05 <br />T- 0" <br />6' - 8" <br />FRENCH DOOR <br />05A <br />5' - 0" <br />6' _ 8" <br />FRENCH DOOR <br />058 <br />5' - 0" <br />6' - 8" <br />FRENCH DOOR <br />06 <br />3' - 0" <br />6' - 8" <br />SWING <br />13A <br />2'- 8" <br />T- 0" <br />SWING <br />13B <br />3'- 0" <br />T- 0" <br />SWING <br />14 <br />2'- 4" <br />7' - 0" <br />POCKET <br />15 <br />2'-6" <br />7'-0" <br />SWING <br />16A <br />3' = 0" <br />7' - 0" <br />SWING <br />17 <br />2'- 8" <br />T- 0" <br />_ <br />SWING <br />17A <br />4'- 0" <br />7'- 0" <br />BYPASS SLIDING DOOR <br />17B <br />4'- 0" <br />7'- 0" <br />BYPASS SLIDING DOOR <br />18 <br />2'- 8'' <br />7' - 0" <br />SWING <br />18A <br />4'- 0" <br />7' - 0" <br />BYPASS SLIDING DOOR <br />18B <br />4'- 0" <br />7'- 0" <br />BYPASS SLIDING DOOR <br />- <br />22A <br />2'- 8" <br />7' - 0" <br />SWING <br />23 <br />4' - 0" <br />7' - 0" <br />DOUBLE POCKET <br />23A <br />2'- 4" <br />T- 0" <br />POCKET <br />24 <br />2'- 8" <br />T- 0" <br />POCKET <br />25 <br />2' - 8" <br />T- 0" <br />SWING <br />25A <br />2' - 8" <br />7' - 0" <br />SWING <br />- <br />(E) WALL <br />WALL <br />DRAWING SYMBOL LEGEND <br />SD <br />SMOKE DETECTOR <br />PER R314.1 <br />S/ <br />SMOKE AND CARBON <br />MONOXIDE ALARM PER <br />R314.1 AND R315.2 <br />[] <br />FAN PER TABLE M1507.3.3 <br />Z/ <br />H K S A R C H I T E C T S <br />1050 N.38th St. <br />Seattle, WA 98103 <br />PH: 206.675.9151 <br />w,vw. sh ksarch itects.cam <br />5 REGISTERED <br />ARC ITECT <br />�JONATHAN H. HAR � U <br />UTA ;1 <br />- TF OF WASHI��GTOi±�'�� <br />Al - <br />BAUGH-FLOYD <br />RESIDENCE <br />PERMIT <br />DRAWINGS <br />5319 Sound Ave. Everett, WA 98203 <br />Drawn by: JI <br />Checked: JH <br />Dater 06/05/20 <br />Scale: 1/4" = 1'-0" <br />Revisions: <br />No. Date Remarks <br />1 06/05/20 PERMIT <br />CORRECTIONS 1 <br />REVIEWED FOR PERMIT - <br />SECOND FLOOR <br />APPROVAL STAMPS <br />