Laserfiche WebLink
w <br />0 <br />WO RO <br />MANUF <br />PADS <br />PRE-EF <br />GUARD <br />CRICKE <br />PER FT <br />SKYLIG <br />SKYLIG <br />CURB, <br />SURFAI <br />FT, TYP <br />(E) GAF <br />FRAMIF <br />5-113/4"+/- <br />11`-61/2" <br />0 2 4 8 <br />VI 1 <br />A R C H I T E C T S <br />HOOF VENTILATION, <br />LONER ROOF — <br />AREA OF LOWER ROOF CAVITY = 725 SF <br />AREA OF VENTILATION REQUIRED =1/150 X 725 SF = 4.833 SF — <br />4.833 SF = 696 SO IN 1050 N. 38th St, <br />Seattle, VVA 93103 <br />4" HOLE IN RIM JOIST = 12.5 SO IN OPEN AREA PER HOLE — PH: 206.675.9151 <br />(696 SO IN REQ'D / 12.5 SO IN) = MIN (56) 4 HOLES, MIN (1) HOLE @ EACH SIDE OF JOIST BAY <br />_ wwuv.shksarchitects.com <br />UPPER ROOF _ �6� REGISTERED <br />ARCHITECT <br />AREA OF UPPER ROOF CAVITY = 823 SF = f <br />AREA OF VENTILATION REQUIRED =1/150 X 823 SF = 5.487 SF <br />5.487 SF = 791 SO IN JQIATHAIN H. NA 'fU G <br />4 HOLE IN RIM JOISTSTATE 'OF WASNI <br />= 12.5 SO IN OPEN AREA PER HOLE <br />(791 SO IN REQ'D / 12.5 SO IN) = MIN (64) 4" HOLES, MIN (2) HOLES @ EACH SIDE OF JOIST BAY <br />BAUGH-FLOYD <br />RESIDENCE <br />PERMIT <br />DRAWINGS <br />5319 Sound Ave. Everett, WA 98203 <br />Drawn by: JI <br />Checked: JH <br />_ Date: 06/05/20 <br />Scale: 1/4" = V-0" <br />Revisions: <br />No. Date Remarks <br />CITY OF EVERETT <br />_ <br />REVIEWED FOR PERMIT <br />APPROVAL STAMPS <br />