Laserfiche WebLink
17RAMING LUMBER <br />WOOD EA5TENER5 <br />1. ALL MATERIALS, DESIGN AND CONSTRUCTION SHALL CONFIRM TO DRAWINGS, SPECIFICATIONS, THE <br />INTERNATIONAL BUILDING CODE IBC 201 8 AND SEATTLE BUILDING CODE MODIFICATIONS 5BC 201 8. <br />RISK CATEGORY <br />2. DESIGN DEAD LOADS <br />Roof <br />FLOOR <br />3. DESIGN LIVE LOADS <br />ROOF <br />FLOOR <br />4. DESIGN SNOW LOAD <br />FLAT ROOF SNOW LOAD <br />SNOW EXF05URE FACTOR <br />SNOW LOAD IMPORTANCE FACTOR <br />THERMAL FACTOR <br />5. WIND DESIGN DATA <br />PROCEDURE <br />BASIC WIND SPEED <br />WIND EXPOSURE <br />Kzt FACTOR <br />GCpi <br />G. SEISMIC DESIGN DATA <br />SEISMIC DESIGN CATEGORY <br />SITE SOIL CLASSIFICATION <br />SEISMIC IMPORTANCE FACTOR <br />BASIC SFR5 <br />RESPONSE MODIFICATION COEF. <br />ANALYSIS PROCEDURE <br />5s <br />51 <br />Sds <br />Sal <br />SEISM RESPONSE COEF C5, ULT/ALL <br />DESIGN BASE SHEAR, ULT <br />15 P5F <br />13 P5F <br />20 P5F <br />40 f 5F <br />25 P5F <br />1.0 <br />1.0 <br />1.0 <br />DIRECTIONAL <br />98 MPH <br />B <br />1.0 <br />0.18 <br />SEE CALC5, SHEET L- I <br />D - DEFAULT <br />1.0 <br />LIGHT FRAMED SHEAKWALLS <br />G.5 <br />ELF <br />1,375 <br />0.487 <br />0.589 <br />O.IG9/0.1 18 <br />SEE CALCS <br />I . THE FOLLOWING SHALL APPLY U.N.O ON THE DRAWINGS. <br />2. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL AND MECHANICAL <br />DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS <br />FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION, <br />3, STRUCTURAL ELEMENTS NOT DIMENSIONED ON STRUCTURAL PLANS SHALL BE LOCATED BY THE <br />ARCHITECTURAL PLANS AND DETAILS, ELEVATIONS OF STRUCTURAL ELEMENTS SHALL BE DETERMINED BY THE <br />ARCHITECTURAL WALL SECTIONS, BUILDING SECTIONS AND BUILDING ELEVATIONS. <br />4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL <br />CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER AND <br />BE RESOLVED BEFORE PROCEEDING WITH THE WORK. <br />5. COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SIZE AND LOCATION OF ALL <br />OPENINGS REQUIRED FOR DUCTS, PIPE5, PIPE SLEEVES, ELECTRICAL CONDUITS, AND OTHER ITEMS TO BE <br />EMBEDDED IN CONCRETE OR OTHERWISE INCORPORATED IN STRUCTURAL WORK. <br />G. CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING FOR ALL STRUCTURAL COMPONENTS UNTIL FINAL <br />CONNECTIONS HAVE BEEN COMPLETED. <br />7. ALL ERECTION PROCEDURES SHALL CONFORM TO 05HA STANDARDS. ANY DEVIATION MUST BE <br />APPROVED BY OSHA PRIOR TO ERECTION. <br />(5. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION PROCEDURES INCLUDING <br />LAGGING, SHORING AND PROTECTION OF ADJACE=NT PROPERTY, STRUCTURES, STREETS AND UTILITIES IN <br />ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY ORDINANCES. <br />9. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL <br />ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. <br />10. DRAWING5 INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT <br />SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF <br />CONSTRUCTION SHALL BE USED SUBJECT TO REVIEW BY THE ENGINEER. <br />1 1. ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL OCCUR IN ADDITION TO ANY OTHER <br />SPECIFIC DETAIL CALLED OUT, <br />1 2. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS 15 GIVEN AS THE BEST <br />PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS CONFLICT <br />WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE ENGINEER SO THAT THE PROPER REVISIONS MAY BE <br />MADE, MODIFICATION TO DETAILS OF CONSTRUCTION SHALL NOT BE MADE WITHOUT PP'IOK WRITTEN <br />APPROVAL OF THE ENGINEER. <br />RENOVATION <br />1. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, MEMBER SIZES AND CONDITIONS BEFORE <br />COMMENCING CONSTRUCTION AND/OR DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING <br />STRUCTURE AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. DEMOLITION DEBRIS <br />SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION <br />LOADING INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 20 P5F. <br />2. CONTRACTOR SHALL CHECK FOR DRY ROT AT ALL AREAS OF NEW WORK. ALL ROT SHALL BE REMOVED <br />AND DAMAGED MEMBERS SHALL BE REPLACED OR REPAIRED AS DIRECTED BY THE STRUCTURAL ENGINEER <br />OR ARCHITECT. <br />1. WOOD FRAMING SHALL CONFORM TO IBC CHAPTER 23 "WOOD",ND5 2018, 5DPW5 2015 AND SHALL BE <br />MARKED IN CONFORMANCE WITH WCLIB STANDARDS: <br />SAWN LUMBER, TYP U.N.O. <br />JOISTS <br />2x, 3x <br />HEM FIR NO.2, Fb=850 PSI <br />BEAMS <br />4x <br />DOUGLAS <br />FIR/LAPCH N0.2, Fb=900 <br />PSI <br />Gx <br />DOUGLAS FIR/LAKCH N0.2, Fb=875 <br />PSI <br />POSTS <br />4x <br />Gx <br />DOUGLAS <br />DOUGLAS <br />FIR/LAKCH NO.2, Fc= <br />FII\/LARCH NO.2, Fc=700 <br />135 PSI <br />PSI <br />TOP AND DOT. PLATES <br />2x, 3x <br />HEM FIR NO.2 <br />STUDS, BLOCKING <br />2x, 3x <br />HEM FIR N0.2 <br />2. STRUCTURAL SHEATHING SHALL BE APA RATED PLYWOOD GRADE C-D, EXTERIOR GLUE OR STRUCTURAL I, <br />EXTERIOR GLUE IN CONFORMANCE WITH DOC PS- I OR P5-2. ORIENTED STRAND BOARD (05B) OF <br />EQUIVALENT THICKNESS, EXPOSURE RATING AND PANEL INDEX MAY BE SUBSTITUTED FOR PLYWOOD <br />LOCATION <br />THICKNE55 <br />SPAN INDEX <br />PANEL GRADE <br />EXPOSURE <br />ROOF <br />1 5/32" <br />32/ 1 G <br />C-D <br />1 <br />FLOOR <br />3/4" T*G <br />48/24 <br />C-D <br />I <br />WALLS <br />1 5/3 2" <br />24/ I G <br />C-D <br />I <br />3, NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY DETAILED OR APPROVED IN <br />WRITING BY THE STRUCTURAL ENGINEER. <br />4. MAXIMUM MOISTURE CONTENT SHALL NOT EXCEED 19 To FOR ALL STRUCTURAL MEMBERS. <br />5. PROVIDE PROPERLY 51ZED WASHERS UNDER HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING <br />ON WOOD. <br />G. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS 1/1 G" UNLESS OTHERWISE NOTED. LAG BOLT <br />PILOT HOLES SHALL BE PRE -DRILLED TO GO% OF THE NOMINAL DIAMETER OF THE LAG DOLT UNLESS <br />OTHERWISE NOTED, <br />7. ALL FRAMING LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED PER <br />AWPA STANDARDS OR WRAPPED WITH (2) LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER. ALL <br />FASTENERS AND CONNECTORS FOR PRESSURE TREATED WOOD OR IN CONTACT WITH MASONRY OR <br />CONCRETE SHALL BE CORROSION RESISTANT PER IBC 2304. 1 0.5. <br />8. FRAMING ANCHORS FOR JOISTS, PURLIN5 AND POSTS SHALL BE "5IMP50N", OR APPROVED EQUAL. <br />APPROVAL MUST BE OBTAINED IN WRITING PRIOR TO INSTALLATION. FILL ALL FASTENER HOLES WITH <br />FASTENER TYPES (NAILS, BOLTS, ETC.), SIZES, AND QUANTITIES AS SPECIFIED BY THE MANUFACTURER. ALL <br />2x JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH SIMPSON "LU5 HANGER. ALL HANGER SHALL HAVE <br />MAX NAILING AS SPECIFIED BY SIMPSON. <br />9, WHERE STRAP CONNECTS (2) MEMBERS - CENTER IT ON THE JOINT AND PLACE ONE-HALF OF THE NAILS <br />OR BOLTS IN EACH MEMBER. REFER TO MANUFACTURER INSTRUCTIONS FOR 5TKAP5 ATTACHED TO <br />CONCRETE. <br />10. RIM JOIST TO BE 2x HF#2 MINIMUM. <br />NTI f 101110 90s <br />1. CONSTRUCTION SHALL CONFIRM TO IBC 2308 AND AITC "TIMBER CONSTRUCTION MANUAL U.N.O. REFER <br />TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS, ELEVATIONS AND OPENINGS. <br />2. ROOF AND FLOOR FRAMING. <br />PROVIDE DOUBLE JOISTS AROUND ALL OPENINGS AND UNDER PARALLEL PARTITIONS U.N.O. USE SOLID <br />BLOCKING UNDER PARTITIONS PERPENDICULAR TO JOISTS. PROVIDE SOLID BLOCKING AT ALL BEARING <br />POINTS. REFER TO PLANS AND DETAILS FOR ATTACHMENT OF JOISTS AND RAFTERS TO SUPPORTS AND <br />FLUSH BEAMS. USE 51MF50N JOIST HANGERS IN ACCORDANCE WITH PLANS, DETAILS AND NOTES. NAIL ALL <br />MULTI -JOISTS BEAMS TOGETHER WITH I Od AT 1 2" O.C. STAGGERED, <br />PLYWOOD ROOF AND FLOOR SHEATHING SHALL BE LAID UP WITH GRAIN PERPENDICULAR TO SUPPORTS <br />AND NAILED WITH 8d NAILS AT G" O.C. TO FRAMED PANEL EDGES AND 1 2" O.C. TO INTERMEDIATE FRAMING <br />SUPPORTS - REFER TO PLANS AND DETAILS FOR ADDITIONAL REQUIREMENTS, PROVIDE APPROVED PLYWOOD <br />EDGE CLIPS CENTERED BETWEEN JOISTS AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING <br />EDGES SHALL HAVE APPROVED TAG JOINTS OR SHALL BE SUPPORTED BY 50LID BLOCKING. PROVIDE <br />MINIMUM OF 3/8" EDGE DISTANCE ON ALL NAILS AND 1 /8" EXPANSION JOIST BETWEEN ALL PANEL EDGES AND <br />PANEL ENDS OF ROOF AND FLOOR SHEATHING, <br />3. WALL FRAMING. <br />ALL EXTERIOR WALLS SHALL BE 2xG AT I G" O.C. MAX U.N.O, INTERIOR BEARING WALLS SHALL BE 2xG <br />AT 24" O.C. OR 2x4 AT I G" O.C. MAX U.N.O, INTERIOR NON -BEARING WALLS SHALL BE 2x4 AT 24" O.C. <br />U.N.O. PROVIDE (2) STUDS MIN AT THE ENDS OF ALL WALLS, AT EA 51DE OF ALL OPENINGS AND AT BEAM <br />BEARING LOCATIONS. NAIL INDIVIDUAL MEMBERS OF BUILT-UP POSTS WITH (2) ROWS OF 1001 AT 12 O.C. <br />PROVIDE (2)2x8 MIN HEADERS AT ALL OPENINGS IN STRUCTURAL WALLS U.N.O. SISTER MULTI -MEMBER <br />HEADERS WITH I Od AT 1 2" O.C. PROVIDE SOLID BLOCKING THROUGH FLOORS TO SUPPORTS BELOW AT ALL <br />WOOD POSTS LOCATIONS. ALL 5TUD5 OVER 1 0'-0" IN HEIGHT SHALL BE BLOCKED WITH CONTINUOUS SOLID <br />BLOCKING AT MID -HEIGHT. <br />ALL WALLS SHALL HAVE DOUBLE TOP PLATES AND SINGLE BOTTOM PLATES. NAIL PLATES TO STUDS <br />WITH (3) 1 Od END NAILS. REFER TO TYPICAL DETAIL FOR TOP PLATE NAILING, NAILING AT TOP PLATE 5PLICE5 <br />MAY BE ELIMINATED W/ CS I Gx32"(L) CENTERED ON THE SPLICE. PROVIDE (3) 1 Od FACE NAILS AT ALL TOP <br />PLATE INTERSECTIONS. <br />ATTACH ALL BOTTOM PLATES OF ALL STUD WALLS TO WOOD FRAMING BELOW WITH I Gd NAILS AT 1 2" <br />O,C, OR 5/8"0 A.B. AT 48" O.C. EMBED 7" MIN IN CONCRETE BELOW, TWO ANCHOR BOLTS MIN PER WALL <br />U.N.O. LOCATE ONE ANCHOR BOLT BETWEEN 4-1/2" AND 1 2" OF EA END OF PLATE SECTION. PROVIDE <br />3"x3"xO.229" WASHERS AT ALL ANCHOR BOLTS. <br />PROVIDE STRUCTURAL SHEATHING PER NOTES ON EXTERIOR SURFACE AND GYPSUM WALLBOARD ON <br />INTERIOR SURFACE U.N.O. REFER TO SHEAKWALL SCHEDULE FOR NAILING REQUIREMENTS FOR STRUCTURAL <br />SHEATHING. FASTEN GWB TO ALL STUDS, POSTS, PLATES AND BLOCKING WITH #Gx i -1/4 TYPE 5 OR W <br />SCREWS AT 1 2" O.C. PROVIDE 1 /8" EXPAN5ION JOIST BETWEEN ALL PANEL_ EDGES AND PANEL ENDS OF WALL <br />SHEATHING. <br />1. FASTENERS AND CONNECTORS SHALL CONFIRM TO IBC 2304. 10 U.N.O. <br />2. NAIL SIZES SPECIFIED ON THE PLANS AND DETAILS ARE BASED ON THE FOLLOWING SPECIFICATIONS: <br />SIZE <br />TYPE <br />LENGTH <br />O <br />801 <br />COMMON <br />2-1 /2" <br />0. 1 3 1" <br />I Od <br />COMMON <br />3" <br />0,14811 <br />1 2d <br />COMMON <br />3-1 /4" <br />0,14811 <br />i Gd <br />COMMON <br />3-1/2 <br />0. 1 G2" <br />3, ALTERNATE NAILS SHALL BE SUBMITTED TO ENGINEER FOR REVIEW AND APPROVAL PRIOR TO <br />CONSTRUCTION. <br />4, STRUCTURAL SHEATHING: NAILS SHALL BE DRIVEN FLUSH WITH FACE OF SHEATHING; NO <br />COUNTERSINKING IS PERMITTED. <br />1. THE FOUNDATION DESIGN IS BASED ON THE RECOMMENDATION IN THE INTERNATIONAL BUILDING CODE <br />TABLE 180G.2. FOUNDATION WORK SHALL BE PERFORMED IN ACCORDANCE WITH CHAPTER 16 Of TH15 <br />CODE, <br />2. THE FOUNDATION DESIGN IS BASED ON THE FOLLOWING VALUES: <br />ALLOW. SOIL (SEARING 1 500 P5F <br />501L FRICTION 35 <br />EQUIV, FLUID PRESSURES <br />ACTIVE PRESSURE N/A <br />PASSIVE PRESSURE N/A <br />3. ALL FOOTINGS SHALL BE FOUNDED AT LEAST 18" BELOW THE UNDISTURBED GROUND SURFACE OR TO <br />FROST DEPTH. ALL FOOTINGS SHALL BE FOUNDED ON COMPACTED FILL OR UNDISTURBED NATURAL. GRADE <br />UNLESS OTHERWISE NOTED. <br />4. COMPACTION: MATERIAL FOR FILLING AND BACKFILLING SHALL CONSIST OF THE EXCAVATED MATERIAL <br />AND/OR IMPORTED 5ORROW AND SHALL BE FREE OF ORGANIC MATTER, TRASH, LUMBER, OR OTHER DEBRIS. <br />ALL WALLS SHALL BE ADEQUATELY BRACED PRIOR TO BACKFILLING. FILL AND BACKFILL SHALL BE DEPOSITED <br />IN LAYERS NOT TO EXCEED 8 INCHES THICK, PROPERLY M015TENED TO APPROXIMATE OPTIMUM <br />REQUIREMENTS AND THOROUGHLY ROLLED OR COMPACTED WITH APPROVED EQUIPMENT IN SUCH A <br />MANNER AND EXTENT AS TO PRODUCE A RELATIVE COMPACTION OF 90% OF MAXIMUM POSSIBLE DENSITY <br />AS DETERMINED BY ASTM D 1 557, HAND TAMPERS SHALL WEIGH AT LEAST 50 POUNDS EACH AND SHALT_ <br />HAVE A FACE AREA NOT IN EXCE55 OF G4 SQUARE INCHES. HAND TAMPERS MAY BE OPERATED EITHER <br />MANUALLY OR MECHANICALLY AND SHALL BE USED WHERE LARGER POWER DRIVEN COMPACTION EQUIPMENT <br />CANNOT BE USED. STRUCTURAL FILL OVER 1 2" DEEP SHALL COMPLY WITH A GEOTECHNICAL REPORT, <br />5. IF 50iL5 ARE FOUND TO BE OTHER THAN ASSUMED, NOTIFY THE STRUCTURAL ENGINEER. <br />CA5T-IN-PLACE CONCRETE <br />I, ALL CONCRETE UNLE55 OTHERWISE NOTED SHALL BE REGULAR WEIGHT HARD ROCK TYPE (1 50 PCF) <br />AGGREGATES SHALL CONFORM TO ASTM C33 WITH PROVEN SHRINKAGE CHARACTERISTICS OF LESS THAN <br />0.05%. <br />2, ALL CONCRETE DE=SIGN IS BASED ON A 28 DAY COMPRESSIVE STRENGTH (f'c) OF 2500 PSI. WHERE <br />3000 PSI CONCRETE- 15 REQUIRED BY THE BUILDING DEPARTMENT FOR WEATHERING PURPOSES ONLY, NO <br />SPECIAL INSPECTION IS REQUIRED, <br />3. CONCRETE EXPOSURE CATEGORIES ARE F 1, 50, WO, C 1. <br />4. CEMENT SHALL CONFORM TO ASTM C 150, TYPE I, CSA NORMAL, <br />5. MAXIMUM SLUMP SHALL NOT EXCEED 4 INCHES IN FLATWORK. <br />G. MIXING, PROPORTIONING AND PLACEMENT OF CONCRETE SHALL BE IN CONFORMANCE WITH ACI 3 18 AND <br />ACI 30 I . <br />7. MINIMUM CONCRETE COVERAGE OF REINFORCING STEEL FOR FORMED WORK SHALL BE AS FOLLOWS: <br />EXTERIOR WALLS, EXPOSED TO WEATHER: I %2" <br />EXPOSED TO I AKTH OR WEATHER (#5 OR SMALLER): 1 �/2" <br />EXPOSED TO EARTH OR WEATHER (#G OR LARGER): 211 <br />NOTE: CONCRETE CAST AGAINST GROUND SHALL HAVE 3" MINIMUM COVERAGE <br />8. PIPES OTHER THAN ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE EXCEPT <br />WHERE SPECIFICALLY APPROVED. <br />9. CONCRETE MIXES SHALL BE PROVIDED IN ACCORDANCE WITH ACI 318 (WHEN STRENGTH DATA FROM <br />TRIAL BATCHES OR FIELD EXPERIENCE ARE NOT AVAILABLE). <br />CEMENT CONTENT <br />5ACK5 PER <br />LB5/CU15IC YARD CUBIC YARD <br />F'c (PSI) (MINIMUM) (MINIMUM) <br />2500 (no Special m5pection) 5 1 7 5-1/2 <br />MIXES SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS. NO MORE THAN A I " PLUS <br />TOLERANCE SHALL BE ALLOWED. <br />DE51GN MIX (OTHER THAN AS SPECIFIED IN THIS TABLE) SHALL BE SUBMITTED TO THE BUILDING OFFICIAL <br />TWO WEEKS PRIOR TO FIRST USE. <br />C,'ITY OF EVERETT <br />REVIEWED FOR PERMIT <br />r <br />E <br />U- <br />i -�: <br />c <br />(n <br />u-i <br />cz' <br />m <br />u� <br />a <br />z3 <br />C) <br />4 <br />O u_j <br />R <br />Lu O <br />'WASry <br />5 <br />44 <br />1911 <br />11 - " , <br />IONAL <br />EXP. 07/17/2022 <br />DATE: <br />1 1121121 <br />PROJECT #: <br />21-022 <br />GENERAL <br />5TRUCTURAL <br />