REINf°ORCING 5TEEL <br />I . ALL REINFORCING STEEL SMALL CONFORM TO ASTM AG 15 GRADE 60 (fy ® 60 K51). <br />WELDED WIRE FABRIC SMALL CONFORM TO A5TM Al OG4 AND SMALL BE Gx6 W2. I /W2, 1 UNLE55 OTHERWISE <br />NOTED. <br />2. ALL REINFORCING STEEL SMALL BE LAPPED AS NOTED ON THE PLANS. WHERE LAP OR SPLICE LOCATIONS <br />ARE NOT SPECIFICALLY INDICATED ON THE CONSTRUCTION DOCUMENTS, LAP5 AND/OR SPLICES SMALL BE <br />48 BAR DIA OR 2'-0" MINIMUM AND BE WELL STAGGERED. <br />LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT 51DE5 AND ENDS. <br />3. COMPLETE REINFORCING PLACEMENT DRAWINGS PREPARED IN ACCORDANCE WITH ACI 3 15 SMALL BE <br />REVIEWED BY THE ENGINEER AND AVAILABLE ON THE JOB SITE PRIOR TO THE PLACING OF CONCRETE. <br />4, ANCHOR BOLTS, DOWELS AND OTHER EMBEDDED ITEMS SHALL BE SECURELY TIED IN PLACE BEFORE <br />CONCRETE 15 POURED, SLAB ON GRADE REINFORCEMENT SHALL BE PLACED AT MID -DEPTH OF SLAB AND <br />SHALL BE HELD SECURELY IN PLACE WITH MECHANICAL DEVICES DURING PLACING OF THE CONCRETE. <br />5. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SMALL BE FIELD BENT UNLE5 SPECIFICALLY 50 <br />DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. <br />P.00E TRU55E5 <br />1. THE TRUSSES SMALL BE DESIGNED BY THE FABRICATOR TO FIT DIMENSIONS AND LOADS INDICATED ON <br />THE PLANS AND IN THE STRUCTURAL NOTES IN ACCORDANCE WITH THE "NATIONAL DE51GN STANDARD FOR <br />METAL PLATE CONNECTED WOOD TRU55 CONSTRUCTION" ANSI / TPI 1. LOADS SMALL BE AS FOLLOWS: <br />TOP CHORD DEAD LOAD 10 P5F <br />TOP CHORD LIVE LOAD 25 P5F <br />BOTTOM CHORD DEAD LOAD 5 P5F <br />TOTAL LOAD 40 P5F <br />TOP CHORD WIND UPLIFT 10 P5F <br />WOOD TRUSSES SMALL UTILIZE APPROVED CONNECTOR PLATES. CONCENTRATED MECHANICAL ROOF LOAD5 <br />SHALL BE INCLUDED IN THE DESIGN. VERIFY WEIGHTS AND LOCATIONS WITH THE ARCHITECT, SHOP <br />DRAWINGS MUST BE RETAINED AT THE JOB 51TE AND AVAILABLE TO THE BUILDING INSPECTOR FOR <br />REFERENCE. THE TRU55 CALCULATION PACKAGE SHALL BE DESIGNED UNDER THE DIRECT 5UFERV15ION OF A <br />PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. THE TRU55 ENGINEER SHALL A55UME <br />ALL RESPONSIBILITY FOR THE WORK OF ALL SUBORDINATES INVOLVED IN THE PREPARATION OF THE TRU55 <br />PLACEMENT PLANS AND THE TRU55 DESIGN DRAWINGS. <br />2, SHOP DRAWINGS AND CALCULATIONS SMALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO <br />FABRICATION, DRAWINGS AND CALCULATIONS SHALL BE STAMPED AND SIGNED BY A REGISTERED <br />PROFESSIONAL ENGINEER. THE DRAWINGS SMALL SHOW ALL CRITICAL DIMENSIONS AS WELL AS THE LOADS <br />THE TRUSSES ARE DESIGNED TO SUPPORT, THE TRUSSES ARE TO BE ERECTED AND INSTALLED IN <br />ACCORDANCE WITH THE PLANS, APPROVED FABRICATOR DRAWINGS, AND INSTALLATION SUGGESTIONS. <br />CONTRACTOR SHALL GIVE NOTIFICATION PRIOR TO ENCLOSING THE TRUSSES TO PROVIDE AN OPPORTUNITY <br />FOR INSPECTION OF THE INSTALLATION, DE51GN AND PROVIDE BRIDGING BETWEEN THE TRUSSES, <br />CONTINUOUS LATERAL BRACING AND DIAGONAL BRACING PER TRU55 MANUFACTURER RECOMMENDATIONS. <br />SHOP DRAWINGS MAY CONTAIN THE MANUFACTURERS ENGINEERING RESPONSIBILITY LIMITATIONS. <br />HOWEVER, THEY SHALL MAKE NO STATEMENT AS TO THE ENGINEER OF RECORD RESPONSIBILITIES. <br />1. 51MF50N TITEN HD: <br />HEAVY DUTY CONCRETE ANCHORS SHALL BE INSTALLED INTO EXISTING CONCRETE IN CONFORMANCE TO ICC-E5 <br />AC 193, ACI 355.2 AND MANUFACTURER'S RECOMMENDATIONS, PROVIDE MINIMUM EMBEDMENT AND EDGE <br />DISTANCE, UNO. <br />2, 51MP50N STRONG BOLT-2: <br />EXPANSION WEDGE ANCHORS SHALL BE INSTALLED INTO EXISTING CONCRETE IN CONFORMANCE TO ICC-E5 <br />E5R-3037 AND MANUFACTURER'S RECOMMENDATIONS. SPECIAL INSPECTION OF INSTALLATION IS REQUIRED <br />3. 5IMP50N "SET-XP" EPDXY ANCHORS: <br />EPDXY GROUTED ALL THREADED RODS AND REINFORCING BARS SHALL BE INSTALLED INTO EXISTING CONCRETE IN <br />CONFORMANCE TO ICC-ES ESK-2508 AND MANUFACTURER'S RECOMMENDATIONS. ATK5 SHALL CONFORM TO <br />A5TM A307. SPECIAL INSPECTION OF INSTALLATION 15 REQUIRED. <br />5HEARWALL SCHEDULE <br />SHEATHING NOMINAL <br />NOMINAL MEMBER <br />SILL PLATE CONN, <br />SHEAR CAPACITY, <br />MARK <br />THICKNESS <br />PANEL EDGE NAILING <br />51ZE AT ADJOINING <br />TOP PLATE CONN <br />PLF <br />PANEL EDGES <br />AT CONCRETE <br />AT WOOD <br />5W 1 <br />1 5/32" ONE FACE <br />8d AT 6" O.C. <br />2x <br />5/8"0 A.B. AT 48" <br />1 6d AT 8" O,C. <br />LTP4/A35 AT 30" <br />230 <br />O.C. <br />O.C. <br />5W2 <br />1 5/32" ONE FACE <br />8d AT 4" O.C. <br />2x <br />5/8"0 A.B. AT 42" <br />1 Gd AT 5" O.C. <br />LTP4/A35 AT 18" <br />350 <br />0.C, <br />0.C, <br />5HEARWALL NOTES <br />. 51-IEARWALL CRITERIA 15 BASED ON TABLE 4.3 OF 5PDW5 2015, <br />2. ALL EXTERIOR WALL5 SHALL BE SW I U.N.O. <br />3. ALL SHEATHING EDGES SMALL BE BACKED WITH 2x4 LAID FLAT. <br />4. NAIL PANELS TO INTERMEDIATE SUPPORTS W/ 8d AT 6" O.C. <br />5. REFER TO "WOOD FASTENERS" NOTES FOR NAILS SIZES. NAILS SHALL NOT BE SPACED LE55 THAN 3/8" FROM E-DGES OF SHEATHING. SHEATHING NAILS SHALL BE <br />DRIVEN 50 THEIR HEADS ARE FLUSH WITH SHEATHING, NOT COUNTERSUNK. <br />6 ,ALL 5HEAKWALL SHEATHING MUST EXTEND TO THE OUTSIDE EDGE OF ALL MOLDOWN POSTS AND CORNERS, AND TO INSIDE EDGE OF FRAMING AROUND OPENING. <br />7. TWO STUDS MINIMUM OR P05T PER PLAN REQUIRED AT EACH END OF 5MEAKWALL5 AND ALL END STUDS SMALL RECEIVE PANEL EDGE NAILING. <br />8. HOLDOWNS MAY BE REQUIRED AT THE ENDS OF SHEAKWALL5. TYPES AND LOCATIONS OF THESE- CONNECTORS ARE INDICATED ON THE PLANS. REFER TO THE <br />APPROPRIATE DETAILS AND/OR HOEDOWN SCHEDULE FOR ADDITIONAL INFORMATION REGARDING ANCHOR BOLTS, EMBEDMENT LENGTH, ETC, <br />9. LTP4 FROM BOTTOM PLATE TO RIM J015T PER SW SCHEDULE CAN BE USED IN LIEU OF BOTTOM PLATE NAILING. <br />10. ANCHOR BOLTS MUST BE EMBEDDED A MINIMUM OF 7" INTO CONCRETE, AND SMALL BE PLACED TO PROVIDE A MINIMUM OF 2" COVER, PROVIDE 3" COVER <br />FOR CONCRETE CAST AGAINST SOIL. PROVIDE 3"x3"xO.229" PLATE WASHERS. THE PLATE WASHER SHALL EXTEND TO WITHIN%2" OF THE EDGE OF THE BOTTOM PLATE <br />ON THE 5HEATHED SIDE. <br />1. ANCHOR BOLTS AT (E)FOUNDATION SHALL BE 51MF50N "5ET-XP" w/ Gil MIN EMBEDMENT OR'"TITEN HD" 8"O x 8 <br />12, WHERE (2) 2x'5 ARE USED AS A HOEDOWN POST, 5MEAKWALL EDGE NAILING MUST BE STAGGERED INTO EACH MEMBER OF THE POST. <br />HOLDOWN 5CHEDULE <br />ANCHOR BOLT / MIN <br />MIN WOOD <br />UPLIFT <br />MODEL ANCHOR <br />EMBEDMENT / MIN I°TG <br />FA5TENER5 <br />MEMBER, <br />EMBEDMENT <br />END <br />CAPACITY, L155 <br />BOLT @ 5TEM <br />51ZE @ ETG <br />U.N.O. ON <br />LENGTH <br />(A5D) <br />PLAN <br />LSTHD8 / KJ - <br />- <br />(20) 1 6d SINKERS <br />(2)2x <br />8" <br />PER MFR <br />STMD 14 / KJ - <br />- <br />(30) 1 6d SINKEK5 <br />(2)2x <br />1411 <br />PER MFR <br />x 3" <br />MSTAM24 5T 5r PS <br />- t ��t <br />NAAI LS5 ; (514) <br />) I/4" x <br />(2) 2x <br />8-3/4" <br />1375 <br />ro m 6Ad <br />604& 0 cljrr <br />1-3/4" TITEN S5 <br />A �1�,� <br />�I <br />(1 3) 0.148 " x 3" <br />MSTAM36 - <br />- � • <br />NAILS; (8) 114" x <br />(2) 2x <br />8-3/4" <br />1 870 <br />-3/4" TITEN 55 <br />1. ALL MOLDOWNS REQUIRE DBL STUD MIN, U.N.O. STUDS MUST BE STITCH NAILED TOGETHER W/ (2)1 Od AT 6" O.C. <br />2. NAILS / SCREWS TO HOEDOWN POST SMALL BE PER MANUFACTURER'S SPECIFICATIONS. <br />3. MINIMUM CONCRETE COMPRESSIVE STRENGTH f'c = 2500 PSI, THICKNESS Gil, der,--,rry 1,y ,4r' o <br />4. PROVIDE FULL WIDTH VERT GRAIN BLOCKING THKU FLOOR TO MATCH MOLDOWN 5TUD5 / PO5T5 <br />5. WHEN FIELD CONDITION BECOME LE55 THAN MINIMUM SHOWN, CONTACT ENGINEER PRIOR TO PROCEEDING. <br />0 <br />DIAMETER <br />A.B. <br />ANCHOR BOLT <br />ABV <br />ABOVE <br />ATR <br />ALL THREADED ROD <br />B <br />BOTTOM <br />BLKG <br />BLOCKING <br />BRG <br />CONN <br />CONT <br />DBL <br />BEARING <br />CONNECTION <br />CONTINUOUS <br />DOUBLE <br />DP <br />DEPTH, DEEP <br />D,5, <br />DRAG STRUT <br />D.T. <br />DRAG TRUSS <br />(E) <br />EA <br />EXISTING <br />EACH <br />FOR <br />ENGINEER OF RECORD <br />EXT <br />FTG <br />EXTERIOR <br />FOOTING <br />GALV <br />GALVANIZED <br />GL <br />_ <br />GLUE LAMINATED TIMBER <br />GC <br />GENERAL CONTRACTOR <br />G,T, <br />GIRDER TRU55 <br />GWB <br />GYPSUM WALLBOARD <br />HD <br />HDG <br />_HOEDOWN <br />MOT -DIP GALVANIZED <br />HDR <br />HEADER <br />IBC <br />INTERNATIONAL BUILDING CODE <br />INT <br />INTERIOR <br />L <br />LENGTH or LONG <br />L5L <br />LAMINATED STRAND LUMBER <br />LVL <br />LAMINATED VENEER LUMBER <br />MFR <br />MANUFACTURED, MANUFACTURER <br />(N) <br />NEW <br />O.C. <br />_ <br />ON CENTER <br />PL <br />P5L <br />PT <br />PLATE <br />PARALLEL STRAND LUMBER <br />PKE55UKE TREATED LUMBER <br />REF <br />REFERENCE <br />55 <br />STAIN LE55 STEEL <br />SW <br />T <br />SHEAKWALL <br />TOP - <br />TYP <br />U.N.O. <br />TYPICAL <br />UNLESS NOTED OTHERWISE <br />VERT <br />VERTICAL <br />V/K I VERIFY / REPLACE WITH <br />REVIEWED FOR PERMIT <br />(n <br />a <br />O <br />Ca <br />1 <br />w <br />Q: <br />�1 <br />OLLJ <br />jvjy ,� <br />A, <br />1911044OAA <br />EXP. 07/17/2022 <br />DATE: <br />1 1121121 <br />PROJECT #: <br />21-022 <br />NFL. <br />T UCTUI AL <br />N T5 <br />(CONT) <br />5 - I , I_j <br />2F v��t (A,-h n'i <br />