Laserfiche WebLink
Residential Plumbing Sewer and Drainage Investigation <br /> Site Address: <br /> 3631 Lombard Ave <br /> 10/01/13 <br /> Ault <br /> O 8 t:. • y <br /> ILL �a� + srVr�. in <br /> ..� <br /> - -_g ~3 <br /> F t <br /> Plumbing and Drainage Inspector: <br /> Steve's Plumbing LLC <br /> 19707 64th Ave W,#108 <br /> Lynnwood,WA 98036 <br /> House Specifics: <br /> • House currently has a backwater valve on side sewer?NO <br /> • House has downspouts connected to side sewer?NO <br /> • Does Side Sewer have grade?YES <br /> • Approximate depth of side sewer: 1' deep at proposed Backwater Valve,8.5' deep at main <br /> • Depth and Location of proposed Backwater Valve: 6'5"N of SE corner 2' E of building 1' depth <br /> Plumbing, Sewer,or Drainage Problems Identified: <br /> 1) House is not protected from surcharge events. <br /> Suggested Solution: install backwater valve at 6'5"N of SE corner 2' east of building (1' depth) <br /> 2) Downspouts discharge immediately adjacent to house foundation. <br /> Suggested Solution: Install splash Block and route downspout discharge a minimum of 3' from house <br /> foundation <br /> 3) Internal Plumbing: existing cast iron c/o is located in downstairs basement E wall <br /> Suggested Solution: installing new c/o existing do cap will not screw back in <br />