My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7805 40TH AVE W 2022-05-12
>
Address Records
>
40TH AVE W
>
7805
>
7805 40TH AVE W 2022-05-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2022 1:23:37 PM
Creation date
5/9/2022 8:08:50 AM
Metadata
Fields
Template:
Address Document
Street Name
40TH AVE W
Street Number
7805
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
271
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TIE ISOLATOR° ROW <br /> 111 <br /> INTRODUCTION <br /> An important component of any Stormwater Pollution Prevention <br /> Plan is inspection and maintenance.The StormTech Isolator Row is a <br /> technique to inexpensively enhance Total Suspended Solids(TSS)and <br /> Total Phosphorus(TP)removal with easy access for inspection and <br /> maintenance. <br /> THE ISOLATOR ROW <br /> The Isolator Row is a row of StormTech chambers,either SC-160,SC- <br /> 310,SC-310-3,SC-740, DC-780, MC-3500 or MC-4500 models,that is Looking down the Isolator Row from the <br /> surrounded with filter fabric and connected to a closely located manhole manhole opening,woven geotextile is shown <br /> for easy access.The fabric-wrapped chambers provide for settling between the chamber and stone base. <br /> and filtration of sediment as storm water rises in the Isolator Row and <br /> ultimately passes through the filter fabric.The open bottom chambers _ <br /> and perforated sidewalls(SC-310,SC-310-3 and SC-740 models)allow <br /> storm water to flow both vertically and horizontally out of the chambers. �_ <br /> Sediments are captured in the Isolator Row protecting the storage areas . + <br /> of the adjacent stone and chambers from sediment accumulation. r <br /> A woven geotextile fabric is placed between the stone and the Isolator <br /> Row chambers.The woven geotextile provides a media for stormwater _ <br /> filtration,a durable surface for maintenance,prevents scour of the <br /> underlying stone and remains intact during high pressure jetting.A non- — s.-, A, , __woven fabric is placed over the chambers to provide a filter media for <br /> flows passing through the perforations in the sidewall of the chamber. - �.. <br /> The non-woven fabric is not required over the SC-160, DC-780, MC-3500 '". 0 ,. `" '' <br /> or MC-4500 models as these chambers do not have perforated side * ' <br /> walls. <br /> The Isolator Row is typically designed to capture the"first flush"and StormTech Isolator Row with <br /> offers the versatility to be sized on a volume basis or flow rate basis. Overflow Spillway(not to scale) <br /> An upstream manhole provides access to the Isolator Row and OPTIONAL <br /> typically includes a high flow weir. When flow rates or volumes exceed PRE-TREATMENT <br /> the Isolator Row weir capacity the water will flow over the weir and <br /> discharge through a manifold to the other chambers. sORMT ow <br /> Another acceptable design uses one open grate inlet structure. Using ,�� <br /> a "high/low"design(low invert elevation on the Isolator Row and a higher _` RangliBli) <br /> >'' 1 <br /> invert elevation on the manifold)an open grate structure can provide the "'A"wr� = 11��1 <br /> advantages of the Isolator Row by creating a differential between the ° 'waa = ��e p <br /> Y <br /> Isolator Row and manifold thus allowing for settlement in the Isolator Row. = --111 p <br /> The Isolator Row may be part of a treatment train system.The design MIMI, p <br /> of the treatment train and selection of pretreatment devices by the ECCENTRIC — --liL ) <br /> design engineer is often driven by regulatory requirements.Whether HEADER  --ell D <br /> pretreatment is used or not,the Isolator Row is recommended by _ --eY <br /> StormTech as an effective means to minimize maintenance requirements = --I} D <br /> and maintenance costs. <br /> Note:See the StormTech Design Manual for detailed information on T. 111111111- D <br /> designing inlets for a StormTech system, including the Isolator Row. °co AL , STORM TECH CHAMBERS <br /> THE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS" <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.