Laserfiche WebLink
• 110 <br /> PUBLIC WORKS' <br /> December 7, 2017 <br /> Doug Engelson <br /> Impression Design <br /> 2418 California, St. Ste. C <br /> Everett, WA 98201 <br /> richardjs2002Cayahoo.com <br /> Owner: New Hewitt/Hodges Assoc LLC <br /> Job Address: 1804 Hewitt <br /> Plan Check No: B1606-075 <br /> RE: Building Permit Review Letter, Recheck #1 <br /> Dear Mr. Engelson, <br /> In response to the application for a building permit, the plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. <br /> General <br /> 1. Electrical permit application #E1712-056 states that the existing wiring within the units <br /> will be re-done. The building plans should show the location of each smoke detector. <br /> The smoke detectors must be hardwired, provided with battery backup and <br /> interconnected within each unit. Section 907.2.11.2 <br /> 2. Electrical permit application E1712-056 proposes to rewire the building floor by floor. <br /> Load calculations in accordance with NEC Article 220.16 must be provided and approved <br /> prior to issuance of that permit. <br /> 3. Interior demolition permit B1712-013 includes revising the exterior windows to vinyl. <br /> This will be required to be approved by Planning. Please contact Kembra Landry. <br /> 4. Carbon monoxide alarms should be shown within each dwelling unit. Section 908.7 <br /> 5. The minimum ceiling heights in the habitable spaces on the mezzanine should be shown <br /> at 7 feet (inspection reports are stating that the ceiling clearance is much less than 7 <br /> feet). IPMC Section 404.3 <br /> Construction <br /> 1. The shaft surrounding the Type I exhaust duct should be shown as minimum 2-hour fire <br /> resistive construction — a listing and assembly should be detailed on the plans. Section <br /> 713.4 <br /> 2)3 <br />