Laserfiche WebLink
Stantec <br />Name <br />NUS-H2 <br />277/480V 3 PH 4W 5000A <br />Main CB <br />Location: <br />NORMAL POWER #2 C-BOO68 <br />Surface Mounted <br />Serves: <br />Tower South Riser Levels B-4 <br />Single Lugs <br />Dem. <br />Load Type <br />Conn KVA <br />NEC Demand Factor <br />Dem. KVA <br />Amps <br />Elevator <br />64.86 <br />Up to 72%, per 620-14 <br />61.62 <br />74 <br />Equip <br />63.88 <br />x 100% <br />63.88 <br />77 <br />Lighting <br />97.12 <br />x 100% <br />97.12 <br />117 <br />Mech <br />27.92 <br />x 100% <br />27.92 <br />34 <br />Motors <br />307.26 <br />)(100% <br />307.26 <br />370 <br />Recept <br />69.46 <br />10 KVA @ 100%, rest @ 50% <br />39.73 <br />48 <br />Recorded Demand 181.44 <br />x 125% <br />226.80 <br />273 <br />Swbd FBCHDP2 Recorded <br />Demand calculated as 181.44kVA)( 100% S.A.F. x 100% O.A.F. <br />Recorded Demand * 437.36 <br />x 125% <br />546.70 <br />658 <br />Swbd FBEHDP2 Recorded <br />Demand calculated as 437.361<VA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand * 146.94 <br />x 125% <br />183.68 <br />221 <br />Swbd FBNHDP2 Recorded Demand calculated as 146.941<VA x 100% S.A.F. <br />x 100% O.A.F. <br />Recorded Demand * 168.75 <br />x 125% <br />210.94 <br />254 <br />Dist PH GAC)H1 Recorded Demand calculated as 168.75kVA x 100% S.A.F. x 100% O.A.F. <br />X-Ray <br />200.50 <br />Largest @ 50%, next @ 25%, rest @ 10% <br />87.63 <br />105 <br />1,765.48 <br />2,124 Amps <br />1,853.25 <br />2,229 <br />NEC Feed <br />X 100% <br />X 100% <br />x 125% <br />125% of Larg <br />125% of Larg <br />X 100% <br />X 100% <br />X 100% <br />��ollylm <br />X 100% <br />Swbd <br />Type: Switchboard <br />100,000 AIC <br />NEC Feed <br />74 <br />77 <br />146 <br />35 <br />430 <br />48 <br />273 <br />658 <br />221 <br />254 <br />105 <br />2,319 <br />Stantec <br />Swbd <br />Name <br />EUS-H2 277/480V 3 PH 4W 5000A <br />Main CB <br />Type: Switchboard <br />Location: <br />EMERG POWER RM C-B0071 <br />Surface Mounted <br />65,000 AIC <br />Serves: <br />Tower South Riser Levels B-4 <br />Single Lugs <br />Dem. <br />Load Type <br />Conn KVA NEC Demand Factor <br />Dem. KVA <br />Amps <br />NEC Feed i <br />NEC Feed Amps <br />Equip <br />46.14 x 100% <br />46.14 <br />56 <br />x 100% <br />56 <br />Lighting <br />43.64 x 100% <br />43.64 <br />52 <br />x 125% <br />66 <br />Motors <br />302.63 x 100% <br />302.63 <br />364 <br />125% of Larg <br />424 <br />Recept <br />50.10 10 KVA @ 100%, rest @ 50% <br />30.05 <br />36 <br />X 100% <br />36 <br />Recorded Demand 181.44 x 125% <br />226.80 <br />273 <br />X 100% <br />273 <br />Swbd FBCHDP2 Recorded Demand calculated as 181.441<VAx 100%S.A.F. <br />x 100% O.A.F. <br />Recorded Demand * 437.36 x 125% <br />546.70 <br />658 <br />X 100% <br />658 <br />Swbd FBEHDP2 Recorded Demand calculated as 437.361<VA x 100%S.A.F.x i00% O.A.F. <br />Recorded Demand * 146.94 x 125% <br />183.68 <br />221 <br />X 100% <br />221 <br />Swbd FBNHDP2 Recorded Demand calculated as 146.94kVAx 100% S.A.F. <br />x 100% O.A.F. <br />X-Ray <br />200.50 Largest @ 50%, next @ 25%, rest @ 10% <br />87.63 <br />105 <br />X 100% <br />105 <br />1408.75 1,694 Amps <br />1,467.26 <br />1,765 <br />1,8381 <br />Stantec <br />Swbd <br />Name S-TVVR-FEED <br />0/4160V 3 PH 3W 800A Main lugs only <br />Type: Switchboard <br />Location: <br />Surface Mounted <br />Serves: <br />Single Lugs <br />Dem. <br />Load Type Conn KVA <br />NEC Demand Factor Dem. KVA <br />Amps <br />NEC Feed i <br />NEC Feed Amps <br />Equip 118.95 <br />x 100% 118.95 <br />17 <br />X 100% <br />17� <br />Lighting 43.64 <br />x 100% 43.64 <br />6 <br />x 125% <br />8� <br />Motors 302.63 <br />x 100% 302.63 <br />42 <br />125% of Larg <br />49 <br />Pat. Room 75.06 <br />50 KVA @ 40%, rest @ 20% 25.01 <br />3 <br />X 100% <br />3 <br />Recept 54.56 <br />10 KVA @ 100%, rest @ 50% 32.28 <br />4 <br />X 100% <br />4 <br />Recorded Demand 28-28 <br />x 125% 35.35 <br />5 <br />X 100% <br />5 <br />Panel F4XHDP4 Recorded <br />Demand calculated as 28.28kVA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand * 73.96 <br />x 125% 92.45 <br />13 <br />X 100% <br />13 <br />Swbd F4CHDP4 Recorded Demand calculated as 73.96kVAx 100% S.A.F. x 100% O.A.F. <br />Recorded Demand " 181.44 <br />x 125% 226.80 <br />31 <br />X 100% <br />31 <br />Swbd FBCHDP2 Recorded Demand calculated as 181.44kVA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand * 257.30 <br />x 125% 321.63 <br />45 <br />X 100% <br />45 <br />Swbd FREHDP4 Recorded Demand calculated as 257.3OkVA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand "' 437.36 <br />x 125% 546.70 <br />76 <br />X 100% <br />76 <br />Swbd FBEHDP2 Recorded Demand calculated as 437.36kVA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand " 146.94 <br />x 125% 183.68 <br />25 <br />X 100% <br />251 <br />Swbd FBNHDP2 Recorded <br />Demand calculated as 146.94kVAx 100%S.A.F. )( 100%0.A.F. <br />X-Ray 200.50 <br />Largest @ 50%, next @ 25%, rest @ 10% 87.63 <br />12 <br />X 100% <br />12 <br />1,920.62 <br />267 Amps 2,016.74 <br />280 <br />288 <br />Stantec <br />Name PMVS-CP 0/4160V 3 PH 3W 2000A Main lugs only <br />Location: UTILITY PLANT PARALLELING GEN RM Surface Mounted <br />Serves: Single Lugs <br />Swbd <br />Type: Switchboard <br />40,000 AIC <br />Dem. <br />Load Type Conn KVA NEC Demand Factor Dem. KVA <br />Amps <br />NEC Feed % <br />NEC Feed Amps <br />Elevator 32.43 Up to 72%, per 620-14 32.43 <br />5 <br />X100% <br />5 <br />Emerg Elevator 32.43 xO% 0.00 <br />0 <br />X100% <br />0 <br />Equip 348.64 x 100% 34&64 <br />48 <br />X100% <br />48 <br />Lighting 74.35 x 100% 74.35 <br />10 <br />x125% <br />13 <br />Mech 5.09 X100% 5.09 <br />1 <br />125% of Largest <br />I <br />Motors 464.43 x100% 464.43 <br />64 <br />125% of Largest <br />71 <br />Pat. Room 167.28 50 KVA @ 40%, rest @ 20% 43.46 <br />6 <br />X100% <br />6 <br />Recept 95.07 10 KVA @ 100%, rest @ 50% 52.53 <br />7 <br />X100% <br />7 <br />Recorded Demand 161.70 x 125% 202.13 <br />28 <br />X 100% <br />28 <br />Swbd AlELDPI Recorded Demand calculated as 161.7OkVA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand * 257.30 x 125% 321.63 <br />45 <br />X 100% <br />45 <br />Swbd FREHDP4 Recorded Demand calculated as 257.30WAx 100% S.A.F. x 100% O.A.F. <br />Recorded Demand * 584.78 x 125% 730.97 <br />101 <br />X100% <br />101 <br />Swbd FBEHDP1 Recorded Demand calculated as 584.78kVA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand * 227.27 x 125% 284.09 <br />39 <br />X100% <br />39 <br />Swbd FREHDP3 Recorded Demand calculated as 227.27kVA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand " 181.44 x 125% 226,80 <br />31 <br />X100% <br />31 <br />Swbd FBCHDP2 Recorded Demand calculated as 181.44kVA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand * 73.96 x 125% 92.45 <br />13 <br />X 100% <br />13 <br />Swbd F4CHDP4 Recorded Demand calculated as73.96kVAx100%S,A.F. x100%0.A.F. <br />Recorded Demand * 152.65 x 125% 190.81 <br />26 <br />X100% <br />26 <br />SwbdAICLDP2 Recorded Demand calculated as 152.65kVA x 100% S.A. F. x 100% O.A.F. <br />Recorded Demand * 217.02 x 125% 271.27 <br />38 <br />X100% <br />38 <br />SwbdA1CLDP1 Recorded Demand calculated as 217.021<VA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand * 19.09 x 125% 23.86 <br />3 <br />X100% <br />3 <br />Dist PnIA1)(LDP1 Recorded Demand calculated asl9.09kVAxI00%S.A.F.xI00%O.A.F. <br />Recorded Demand * 168.75 x 125% 210.94 <br />29 <br />X100% <br />29 <br />Dist PnI GAOH1 Recorded Demand calculated as 168.75kVA x 100%, S.A,F. x 100% O.A.F. <br />Recorded Demand * 946.51 x 125% 1,18114 <br />164 <br />X100% <br />164 <br />Swbd PMOHDPI Recorded Demand calculated as 946.51kVAx 1001,VoS.A.F. x 100%0.A.F. <br />Recorded Demand * 14.13 x 125% 17.66 <br />2 <br />X 100% <br />2 <br />Panel PlXF11 Recorded Demand calculated as 14.13kVA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand * 135.35 x 125% 169.19 <br />23 <br />X100% <br />23 <br />Swbd PIEHDPI Recorded Demand calculated asl35.35kVAxl00%S.A.F.xI00%O.A.F. <br />Recorded Demand * 146.94 x 125% 183.68 <br />25 <br />X100% <br />25 <br />Swbd FBNHDP2 Recorded Demand calculated as 146.94kVAx 10OTo S.A.F. x 100% O.A.F. <br />Recorded Demand * 437.36 x 125% 546.70 <br />76 <br />X100% <br />76 <br />Swbd FBEHDP2 Recorded Demand calculated as 437.36kVA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand " 56.84 x 125% 71.05 <br />10 <br />X100% <br />10 <br />Swbd FRCHDP3 Recorded Demand calculated as 56.84kVA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand * 28.28 x 125% 35.35 <br />5 <br />X100% <br />5 <br />Panel F4XHDP4 Recorded Demand calculated as 28.28kVAx 100% S.A.F. x 100% O.A.F. <br />Recorded Demand * 40.40 x 125% 50.50 <br />7 <br />X 100% <br />7 <br />Panel FBXHDP1 Recorded Demand calculated as 40.4OkVA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand * 24.00 x 125% 30.00 <br />4 <br />X 100% <br />4 <br />Panel FRXHDP3 Recorded Demand calculated as 24.00kVA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand * 80.30 x 125% 100.38 <br />14 <br />X 100% <br />14 <br />Dist Pril DIEH1 Recorded Demand calculated as 80.301<VA x 100% S.A.F. x 100% O.A.F. <br />Recorded Demand * 160.00 x 125% 200.00 <br />28 <br />X 100% <br />28 <br />Swbd FBCHDP1 Recorded Demand calculated as 160.00kVA x 100% S.A.F. x 100% O.A.F. <br />X-Ray 200.50 Largest @ 50%, next @ 25%, rest @ 10% 87.63 <br />12 <br />X100% <br />12 <br />5,534.28 768 Amps 6,251.14 <br />868 <br />877 <br />go" <br />27127 Oulm Ave. <br />sulft 100 <br />Evemt WA 98201 <br />REVISIONS <br />Ast tec- <br />2s, <br />4100 194th Street SW Suite 400 <br />Lynnwood Washington 98036-4613 <br />(206) 667-0555 <br />Copyright Reserved <br />The Contractor shall verify and be responsible for all dimensions. DO <br />NOT scale the drawing - any errors or omissions shall be reported to <br />Stantec without delay. <br />The Copyrights to all designs and drawings are the property of <br />Stantec. Reproduction or use for any purpose other than that <br />authorized by Stantec is forbidden. <br />Mw. 10-1017 <br />BPAW BY JT <br />CHEMM N Joe <br />PM <br />