G <br />REFER TO SHEET E8.21 FOR CONTINUATION <br />TO ATS-CE TO ATS-C TO A1NLDP1 TO ATS-NE TO CHILLER #1 TO ATS-LS <br />7 <br />1500/1680/1875 KVA, <br />KHAN/KHAN-65/KNAF <br />,:208/120V 34, <br />4W, <br />W5.75% Z <br />4W5. <br />PM <br />1600AF 160OAF <br />( ( <br />1200AF <br />1200AF <br />1200AF <br />1200AF 1200AF 1200AF <br />T <br />GF <br />1600AT 1600AT <br />v <br />1000AT ( <br />1200AT ( <br />800AT ( <br />400AT ( 1200AT ( 1200AT <br />A <br />___� � � k- <br />- - �'] <br />-<< <br />K <br />5000AF <br />5000AT <br />600AS <br />600AS <br />150AF <br />�� <br />N <br />N.C. K <br />K <br />N.O. <br />G <br />B <br />A <br />= <br />NUS-EH1 HOSPITAL NORMAL POWER 5000A <br />BUS (A -WING) <br />12.47kV//120/208V, 30, 4W <br />100,000 AIC Q 208V <br />SERVICE ENTRANCE RATED <br />F. cl <br />60OAF <br />TOWER "B" 600AS <br />N.C.�� <br />REFER TO SHEET E8.13 <br />FOR CONTINUATION <br />TO ATS-X3 TO ATS-C3 TO FRNHDP3 TO ATS-E3 <br />T T 'r 'r <br />1600AF <br />1000AT GF <br />800AF <br />225AT GF <br />1600AF <br />1000AT <br />1600AF <br />1000AT <br />2000AF i�\1600AF 1600AF <br />2000AT 1000AT 1000AT <br />GF <br />GF ( <br />OF OF ( <br />N <br />G - <br />ER TO SHEET E8.08 <br />CONTINUATION <br />1 TO FBNHDPI TO ATS-El <br />'1' '1 <br />1600AF 1600AF 3200AF 1600AF 7�1600AF <br />1600AT OF 1600AT GF 3000AT OF 1000AT GF 1000AT <br />N <br />G - <br />300AF 30OAF 600AF <br />AS <br />CUP "A" 600AS CUP "B" AS TOWER "A" <br />N.C. N.C. N.C.�� <br />SERVICE DISCONNECT - <br />SWITCHES SERVICE DISCONNECT <br />15KV,3P CA CA CA A SWITCHES <br />AD SWITCHES <br />P <br />A 9-- <br />J � <br />TO UTILITY COMPANY <br />EQUIPMENT ON SITE <br />7 CQ <br />® 111 <br />TO UTILITY COMPANY <br />EQUIPMENT ON SITE <br />P.U.D. SW #4 P.U.D. SW #5 P.U.D. SW #6 <br />P.U.D. PRIMARY P.U.D. PRIMARY P.U.D. PRIMARY <br />PM1 METER EQUIPMENT PM2 METER EQUIPMENT PM3 METER EQUIPMENT <br />METER #127260 METER #129973 METER #129972 <br />EQUIPMENT <br />LOCATED IN <br />P.U.D. <br />SWITCH <br />ROOM AT <br />PARKING <br />T _T_ GARAGE <br />FaI0111111ILWIM <br />____j . \ . = __j - <br />P.U.D. SW #2 P.U.D. SW #3 <br />UTILITY #2 UTILITY #3 UTILITY #1 <br />NORTON FEEDER DELTA FEEDER 10TH ST. FEEDER <br />12.47KV 12.47KV 12,47KV <br />CKT 12-589 CKT 12-3656 CKT 12-298 <br />C I I C <br />19,488 <br />MEDIUM VOLTAGE FEEDER SCHEDULE <br />FEEDER <br />COPPER CONDUCTORS <br />FEEDER <br />TEE <br />AMPACITY <br />RACEWAY <br />WIRE <br />A <br />5. <br />133% XHHW <br />EPR, (1B) 4/OGM600V <br />(NOTE 1) <br />3 <br />5° <br />(3) #350kcml 15KV, MV-105 <br />415 <br />133% EPR, (1) #11OG 600V XHHW <br />(3) 4/0 15KV, MV-105 <br />C <br />4® <br />133% EPR, (1) 1/OG 600V XHHW <br />315 <br />2E <br />(2)4® <br />(3) 350kcm11 5KV, MV-105 <br />830 <br />133PR, (1) 1/OG, 600V XHHW IN EA. <br />3E1 <br />(3)4m <br />(3) 350kcm11 5KV, MV-105 <br />810 <br />1331PR, (1) 2/OG, 600V XHHW 1N EA. <br />(NOTE 1) <br />3E2 <br />(3) 350kcmiI 5KV, MV-105 <br />873 <br />133%EPR, (1) #2/OG, 600V XHHW IN EA. <br />(NOTE 1) <br />F <br />5® <br />(3) 500kcmIl SKV, MV-105 <br />470 <br />133 EPR, (1) 1/0G, 600Y XHHW <br />(NOTE 2) <br />F1 <br />5� <br />(3) 500kcm11 5KV, MV-105 <br />348 <br />133 EPR, (1) #1/OG, 6OOV XHHW <br />(NOTE 1) <br />G <br />6W <br />(3) 350kcm11 15K19 MV-105 <br />41 S <br />133 EPR, (1) 1 /OG, 600V XHHW <br />N®1F_ 1: FEEDER AMPACITY BASED ON DUCT BANK STEADY STATE THERMAL/AMPACITY ANALYSIS, <br />NOTE 2: [FEEDER AMPACITY BASED ON ONE CIRCUIT IN DUCT BANK PER NEC TABLE 310m77, <br />PROTECTIVE DEVICE SCHEDULE <br />7!!!it e I 2 r <br />1 <br />m .6 49, 50, 50N, 5„ 51N,59 59N, <br />GENERATOR R,I f. PROTECTION � <br />tl 50N, 51, 9 " <br />METERING, MONITORING <br />! "aa <br />n <br />L�Ik a' f <br />.:. <br />I.. <br />I, III III <br />i -� <br />�i <br />®I <br />PRESSURE SW7CH RELAY <br />it <br />NOTE I I. RELAY TYPES ARE SCHWEITZER ENGINEERING I f I f (SE MODEL 1EI :, B7f FOR DESIGN <br />BASIS ONLY. CONTRACTOR SHALL MODIFY AS NECESSARY IF SEL DEVICES ARE NOT Ur,-X,). <br />REFER TO SHEET E8.05 <br />FOR CONTINUATION <br />TO ATS-X4 TO ATS-C4 TO F4NHDP4 TO ATS-E4 <br />'r 'r 'r T <br />GENERAL NOTE: <br />1. i FAULT CURRENTS SHOWN REPRESENT SIMULATED <br />:0 BOLTED FAULTS UNLESSOTHERMSE NOTED. SEE <br />FLAG FOR EXCEPTION. <br />SPARE RACEWAY SAME SIZE AS FEEDER DER RACEWAY I <br />WITH IDES <br />KEY INTERLOCK TO PREVENT SIMULTANEOUS <br />BOTH SIMTCHES AND TO PREVENT ACCESS TO PRIMARY <br />FUSE COMPARTMENT WdEN EITHER PRIMARY SWTCH IS <br />0-but".. NOT USED. <br />r. IMF. <br />a`TRANSFORMER EQUIPPED NTH PROVIO, n, FUTURE <br />FANS TO i "k ID K` iRATING. <br />2000/2240/2500 KVA, <br />KNAN/KNAN-65/KNAF <br />_ <br />12.7KV: 480Y/277 <br />30, 4W, 5.75% Z <br />1600AF 1600AF 800AF 1600AF 1600AF 2000AF 1600AF 1600AF <br />1000AT OF 1000AT GF 225AT GF 1600AT GF 1200AT OF 2000AT 1000AT 1000AT <br />TGF <br />OF GF ( <br />SA <br />K <br />3000AF <br />3000AT <br />600AS <br />115 AAF <br />�9c� <br />N <br />N.O. K <br />K <br />N.C. <br />G <br />A <br />B <br />NUS-H4 HOSPITAL NORMAL POWER <br />3000A BUS (LEVEL 4 - SOUTH) <br />12.47kV//480Y/277V 30 4W <br />65,000 AIC @ 480V <br />SERVICE ENTRANCE RATED <br />B DB <br />TO D-WING FIRE PUMP. <br />� ' SEE SHEET E8.02 FOR CONTINUATION. <br />REFER TO SHEET E8.02 <br />FOR CONTINUATION <br />h <br />TO ATS-X2 TO ATS-C2 TO ATS-02 TO ATS-E2 <br />TO SWBD MSB-G IN PARKING <br />GARAGE. SEE GARAGE POWER <br />RISER FOR CONTINUATION <br />3750/4200/4688KVA, <br />KNAN/KNAN-65/KNAF <br />_ <br />12.7KV: 480Y/277 <br />30, 4W, 5.75% Z <br />1600AF 1600AF <br />800AF <br />1600AF <br />1600AF <br />3200AF <br />1600AF 1600AF <br />T <br />Q <br />OF OF OF <br />10QOAT 1000AT <br />OF <br />225AT <br />1600AT GF <br />1200AT GF <br />� <br />3000AT GF <br />�( <br />1200AT OF 1000AT <br />SA <br />5000AF <br />5000AT <br />600ASNK <br />g250AF <br />GA <br />ZyN.C. <br />N.O. <br />= <br />NUS-H2 HOSPITAL NORMAL POWER <br />5000A BUS (LEVEL B - SOUTH) <br />12.47kV//480Y/277V 30 4W <br />100,000 AIC ® 480V <br />SERVICE ENTRANCE RATED <br />REFER TO CUP POWER RISER <br />L LISTED LESS -FLAMMABLE FLUID FILLED <br />FOR CONTINUATION <br />NVIROTEMP) <br />A <br />YPiCAL ALL NORMAL POWER UNIT <br />UBSTATIONS <br />TO ATS-P1XH1 <br />TO CHWP-5 <br />TO CH-1 <br />T <br />T <br />T <br />TO P1NHDP1 TO ATS-PMOHDPI <br />T T <br />2500/2800/3125KVA, <br />KNAN/KNAN-65/KNAF <br />SPARE SPACE SPACE <br />SPARE <br />PM <br />= <br />12.7KV-. 480Y/277 <br />30, 4W, 5.75% Z <br />PM <br />(, 800AF + <br />2000AF 1600AF <br />800AF <br />800AF <br />800AF 800AF <br />1600AF <br />T <br />OF <br />\G� <br />\ <br />OF 225AT GF <br />450AT OF <br />500AT OF <br />OF 1600AT GF <br />2500AT <br />2500AT <br />SA <br />K <br />600AS <br />I <br />'-' <br />4000AF <br />4000AT <br />C3 <br />\ �2 <br />600AS <br />200AF <br />O <br />K <br />N.O. <br />K N.C. <br />N I <br />G <br />B <br />A <br />NUS-CP1 C.U.P NORMAL POWER <br />4000A BUS (CENTRAL UTILITY PLANT) <br />12470V - 480Y/277V 30, 4W <br />65,000 AIC @ 480V <br />SERVICE ENTRANCE RATED <br />TO CUP FIRE PUMP <br />SEE SHEET E8.30 FOR <br />CONTINUATION <br />REFER TO CUP POWER RISER FOR <br />CONTINUATION <br />TO CH-5 TO CHWP-2 TO CH-3 TO CH-4 TO ATS-PIEHDPI <br />2500/2800/3125KVA, <br />KNAN/KNAN-65/KNAF1600AF <br />SPACE SPARE <br />SPARE <br />12.7KV: 480Y/277 <br />30, 4W, 5.75% Z <br />PM <br />1600AF <br />2000AF <br />1600AF <br />800A <br />1600AF <br />1600AF 1600AF <br />GF <br />GF OF <br />1400AT GF <br />350A <br />GF <br />1400AT GF <br />1400AT GF 1200AT GF <br />K <br />600AS <br />4000AF <br />4000AT <br />S <br />9 <br />a200AF <br />N <br />K <br />N.O. <br />G <br />A <br />-------- - - - - - <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />------------- <br />FUTURE SWITCHGEAR SECTION <br />------- - - - - - - <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />_ - <br />FUTURE SWITCHGEAR SECTION <br />CR REFERENCE OND <br />suite 100 <br />Evenit WA 98201 <br />REVISIONS <br />5 stantec <br />4100 194th Street SW Suite 400 <br />Lynnwood Washington 98036-4613 <br />(206) 667-0555 <br />Copyright Reserved <br />The Contractor shall verify and be responsible for all dimensions. DO <br />NOT scale the drawing - any errors or omissions shall be reported to <br />Stantec without delay. <br />The Copyrights to all designs and drawings are the property of <br />Stantec. Reproduction or use for any purpose otherthan that <br />authorized by Stantec is forbidden. <br />am <br />Ls <br />Loa <br />C <br />TMM <br />E <br />WIN= <br />0 <br />a's <br />ZZ <br />x <br />0 <br />> <br />IM <br />00 <br />e10-1017 <br />Vol <br />