� F1 E1 D1 C1 B2 �1
<br />1
<br />i I I I I I
<br />i
<br />27' _ 7 1 /2" IT
<br />1 18 0
<br />I
<br />0"
<br />I I 1
<br />1�
<br />SEE 1/D1 02
<br />E a
<br />Gm
<br />MATCHLINE
<br />D11(Di
<br />I Jill I r
<br />i
<br />- � �, i �i I i D11 D3�
<br />�/ � MEN'S Ia�l �MEN�S� �� —
<br />I I
<br />D1® i D14 D14 F//x
<br />D97 ? �17ft—
<br />= ��i1Al
<br />BREAD ROOM�i D18i it I D18 �, �i D1 D2.01 j
<br />� � D19 it g` CD19
<br />SCALE: 1/8" = V-0"
<br />T
<br />SEE 1/D 1 02a
<br />- — 1
<br />MATCHj INE
<br />®38
<br />D15
<br />D36r
<br />�4
<br />D12
<br />D11
<br />��
<br />II
<br />i
<br />C
<br />ALIGN EDGE OF OPENING WI FACE
<br />OF GLU-LAM COLUMN BELOW
<br />I
<br />1
<br />1
<br />—
<br />I
<br />— 5
<br />_ [D6
<br />TYP
<br />6
<br />�Mlmlfftm
<br />Dp
<br />_ 7
<br />PEMOLITION NOTES
<br />1. DASHED LINES INDICATE OBJECTS TO BE DEMOLISHED AND / OR SALVAGED.
<br />2. ITEMS SALVAGED FOR RE -USE SHALL BE SAFELY STORED AND PROTECTED FROM DAMAGE DURING
<br />CONSTRUCTION.
<br />3. EXISTING FURNITURE, DECORATIVE LIGHTING, & EQUIPMENT NOT TO BE RE -USED, CONTRACTOR TO
<br />BE RESPONSIBLE FOR SALVAGING FOR RECYCLING OR DISPOSAL AS REQUIRED.
<br />4. REFER TO THE REFLECTED CEILING PLANS FOR ADDITIONAL DEMO NOTES SPECIFIC TO THE EXISTING
<br />CEILING CONDITIONS.
<br />5. CONTRACTOR IS RESPONSIBLE FOR THE SAFE REMOVAL OF ANY AND ALL MATERIALS REFERRED TO
<br />IN THE MED-TOX 2007 HAZARDOUS BUILDING MATERIALS SURVEY. SHOULD THE CONTRACTOR
<br />ENCOUNTER ANY ADDITIONAL ASBESTOS MATERIALS, PCB'S, OR OTHER TOXIC SUBSTANCES NOT
<br />NOTED IN SURVEY,THE CONTRACTOR SHOULD IMME fATr LY REPORT THE FINDINGS IN WRITING
<br />F
<br />TO THE BUILDING OWNER TENANT PRIOR T WORK iN THE AREA. WORK
<br />& IO 0 CONTINUING WITH ANY O
<br />I F
<br />SHALL NOT BE _ RESUMED EXCEPT BY WRITTEN AUTHORIZATION OR AGREEMENT FROM THE OWNER.
<br />6. EXISTING HVAC EQUIPMENT, PLUMBING, DRAIN & FIRE PROTECTION LINES TO BE DEMOLISHED
<br />EXCEPT AS NOTED. REFER TO MECHANICAL AND PLUMBING DEMOLITION DRAWINGS FOR FULL
<br />EXTENT OF DEMO. CONTRACTOR SHALL VERIFY EXISTING ITEMS TO REMAIN WITH
<br />ARCHITECT/MECHANICAL DESIGNER. COORDINATE WITH PROPERTY PRIOR TO INTERFERING WITH
<br />EXISTING UTILITIES.
<br />7. THE PLANS/ELEVATIONS ARE DERIVED FROM ARCHIVAL BUILDING PLANS & ARE INTENDED TO
<br />REASONABLY REPRESENT EXISTING CONDITIONS. ACTUAL CONDITIONS MAY DEVIATE FROM THAT
<br />SHOWN ON THE DRAWINGS. THE DEMO NOTES IDENTIFY SPECIFIC AREAS OF WORK, BUT MAY NOT BE
<br />COMPLETE IN THE IDENTIFICATION OF ALL REMOVALS. THE CONTRACTOR SHALL VERIFY ACTUAL
<br />CONDITIONS & COORDINATE DEMO WITH NEW WORK SO THAT DEMO IS COMPLETE.
<br />8. EXISTING LIGHT FIXTURES AND ELECTRICAL COMPONENTS TO BE REMOVED EXCEPT AS NOTED.
<br />REFER TO ELECTRICAL DEMOLITION PLANS FOR FULL EXTENT OF DEMOLITION AND FIXTURES BEING
<br />REMOVED.
<br />9. EXISTING FINISHES WILL BE REMOVED IN THEIR ENTIRETY WHERE INDICATED AND EXPOSED
<br />SURFACES PREPARED FOR NEW FINISHES.
<br />10. ALL WORK WHICH IS TO REMAIN SHALL BE PROTECTED FROM DAMAGE AND, IF DAMAGED, SHALL BE
<br />REPAIRED AT NO COST TO THE OWNER. PROVIDE DUST ISOLATION & PROTECTION TO LIMIT DUST TO
<br />AREAS OF WORK.
<br />D5 REMOVE (E) WINDOWS AND CONCRETE WALL TO EXTENTS SHOWN, REMOVE INTERIOR
<br />INSULATION AND GYP BOARD ONLY TO SAME EXTENTS AS WALL REMOVAL OR AS
<br />REQUIRED FOR STRUCTURAL RETROFIT. CONCRETE TO BE SAWCUT FOR SMOOTH, EVEN
<br />EDGE. REFER TO DEMO ELEVATIONS D2.01 FOR ADDITIONAL INFORMATION,
<br />D6 REMOVE (E) WINDOW. PRESERVE AND PROTECT OPENING FOR NEW WINDOW
<br />REPLACEMENT.
<br />D10 REMOVE (E) CABINETS AND/OR COUNTEROP.
<br />D11 REMOVE (E) INTERIOR WALLAS INDICATED,
<br />D12 REMOVE (E) INTERIOR DOOR AND FRAME.
<br />D13 REMOVE (E) GYP/PLASTER FINISH TO EXPOSE WOOD COLUMN, TYP. USE CAUTION TO AVOID
<br />DAMAGE TO COLUMN SURFACE AND STRUCTURAL INTEGRITY DURING DEMO.
<br />D14 REMOVE (E) VINYL FLOORING AND RUBBER BASE. SCRAPE ADHESIVE AS REQUIRED AND
<br />PREP FOR NEW FLOOR FINISH,
<br />D15 REMOVE (E) CARPET OR CARPET TILE, PADDING, AND RUBBER BASE, SCRAPE ADHESIVE AS
<br />REQUIRED AND PREP FOR NEW FLOOR FINISH.
<br />D16 REMOVE (E) ACOUSTIC TILE CEILING, GRID, AND SUPPORT. REMOVE ALL CEILING MOUNTED
<br />LIGHT FIXTURES AND HVAC REGISTERS. SEE ELECTRICAL AND MECHANICAL FOR
<br />ADDITIONAL INFORMATION, SEE FIRE PROTECTION DRAWINGS FOR SPRINKLER SYSTEM
<br />REMOVAL.
<br />D17 REMOVE (E) TOILET PARTITIONS. FILL HOLES AND PATCH AND/OR LEVEL CONCRETE AS
<br />REQUIRED FOR SMOOTH, LEVEL SURFACE,
<br />D18 REMOVE (E) RESTROOM ACCESSORIES INCLUDING BUT NOT LIMITED TO MIRRORS; GRAB
<br />BARS, PAPER TOWEL, TOILET PAPER, SOAP, AND FEMININE HYGEINE DISPENSERS; AND
<br />WASTE RECEPTACLES,
<br />D19 REMOVE (E) PLUMBING FIXTURE(S) AS SHOWN, SUPPLY AND DRAIN PIPING TO BE REMOVED
<br />AND FILLED OR CAPPED AS DIRECTED IN PLUMBING DRAWINGS.
<br />D25 REMOVE (E) CONCRETE SLAB OR FLOOR STRUCTURE FOR NEW ELEVATOR PIT AND SHAFT.
<br />SEE SLAB PLAN SHEET A2.01s FOR DIMENSIONS.
<br />D30 REMOVE (E) FLOOR STRUCTURE THIS AREA AS REQUIRED FOR NEW TWO-STORY OPENING.
<br />PROVIDE TEMPORARY SUPPORT FOR FLOOR DECKING TO REMAIN UNTIL NEW STRUCTURE
<br />IS COMPLETE. SEE STRUCTURAL,
<br />D33 REMOVE (F_) COLUMN AND SALVAGE FOR RECYCLING, PROVIDE TEMPORARY SUPPORT TO
<br />PROTECT STRUCTURAL INTEGRITY DURING DEMOLITION. SEE STRUCTURAL.
<br />D34 REMOVE (E) GLU-LAM BEAM BETWEEN LIMITS OF ATRIUM. PROVIDE TEMPORARY SUPPORT
<br />AS REQUIRED, CUT EDGES TO BE CLEAN AND PLUMB, PROTECT BEAM TO REMAIN FROM
<br />DAMAGE. SEE STRUCTURAL.
<br />D36 REMOVE (E) ACOUSTIC CEILING TILES, CEILING GRID AND SUPPORT TO REMAIN AND BE
<br />REPAINTED.
<br />D37 REMOVE (E) WOOD HANDRAILS AND BRACKETS. PATCH WALL SURFACE AS REQUIRED FOR
<br />SMOOTH CONSISTENT FINISH.
<br />D38 REMOVE (E) GUARDRAIUHANDRAILS AND WOOD TRIM AS REQUIRED FOR NEW PARTIAL
<br />HEIGHT WALL INSTALLATION, PATCH WALLS AND OTHER SURFACES TO REMAIN AS
<br />REQUIRED FOR SMOOTH CONSISTENT FINISH,
<br />D39 SAWCUT AND REMOVE (E) CONCRETE FOR NEW WINDOW OPENING. REFERENCE DEMO
<br />D53 REMOVE (E) OVERHEAD ROLL -UP DOOR, FRAME, AND OPERATING MECHANISM.
<br />D54 REMOVE (E) CONCRETE SLAB OR FLOOR STRUCTURE FOR NEW MECHANICALSHAFT.
<br />D55 REMOVE (E) WALL AS REQUIRED FOR NEW SHEAR WALL, SEE STRUCTURAL DRAWINGS.
<br />LEVEL 02-A
<br />CITY OF
<br />l �
<br />0' 4" 8' 16'KEY PLAN
<br />�-hftects, Inc.
<br />808 S"Im;�J* IUD, Ste'D0
<br />�*
<br />.h R .287. 32
<br />1� 1 .cr3M
<br />}
<br />Vx �
<br />STAMP
<br />CONSULTANT
<br />TITLE
<br /># DATE DESCRI
<br />A 04/17/2020 PLAN REo
<br />REVISIONS
<br />0
<br />0
<br />'TION
<br />(ISIONS
<br />KE, MS VVY, JG
<br />DRAWN BY CHECK BY
<br />100% ISSUE SET/BID SET
<br />STATUS
<br />04/17/2020
<br />DATE ---
<br />328801
<br />PROJECT NUMBER
<br />D1
<br />02b
<br />w
<br />0 2020 OTAK, INC.
<br />If this drawing is not 24" x 36", it has been
<br />reduced/enlarged. Scale accordingly.