Laserfiche WebLink
G F1 E1 ®l C1 B2 131 Al <br />D2.t}1 <br />I I I 1 I I <br />I 1 a <br />I I I I I ! I <br />4 <br />SCALE: 1/8" = V-0" <br />bAA <br />— lA <br />MATCHLINE <br />SEE1/D1.02b <br />I <br />DEMOLITION <br />1. DASHED LINES INDICATE OBJECTS TO BE DEMOLISHED AND / OR SALVAGED. <br />2. ITEMS SALVAGED FOR RE -USE SHALL BE SAFELY STORED AND PROTECTED FROM DAMAGE DURING <br />CONSTRUCTION. <br />3. EXISTING FURNITURE, DECORATIVE LIGHTING, & EQUIPMENT NOT TO BE RE -USED. CONTRACTOR TO <br />BE RESPONSIBLE FOR SALVAGING FOR RECYCLING OR DISPOSAL AS REQUIRED. <br />4. REFER TO THE REFLECTED CEILING PLANS FOR ADDITIONAL DEMO NOTES SPECIFIC TO THE EXISTING <br />CEILING CONDITIONS. <br />5. CONTRACTOR IS RESPONSIBLE FOR THE SAFE REMOVAL OF ANY AND ALL MATERIALS REFERRED TO <br />IN THE MED-TOX 2007 HAZARDOUS BUILDING MATERIALS SURVEY. SHOULD THE CONTRACTOR <br />ENCOUNTER ANY ADDITIONAL ASBESTOS MATERIALS, PCB'S, OR OTHER TOXIC SUBS T ANCES NOT <br />NOTED IN THE SURVEY, THE CONTRACTOR SHOULD IMMEDIATELY REPORT THE FINDINGS IN WRITING <br />TO THE BUILDING OWNER & TENANT, PRIOR TO CONTINUING WITH ANY WORK IN THE AREA. WORK <br />SHALL NOT BE RESUMED EXCEPT BY WRITTEN AUTHORIZATION OR AGREEMENT FROM THE OWNER. <br />6. EXISTING HVAC EQUIPMENT, PLUMBING, DRAIN & FIRE PROTECTION LINES TO BE DEMOLISHED <br />EXCEPT AS NOTED. REFER TO MECHANICAL AND PLUMBING DEMOLITION DRAWINGS FOR FULL <br />EXTENT OF DEMO. CONTRACTOR SHALL VERIFY EXISTING ITEMS TO REMAIN WITH <br />ARCHITECT/MECHANICAL DESIGNER. COORDINATE WITH PROPERTY PRIOR TO INTERFERING WITH <br />EXISTING UTILITIES. <br />7, THE PLANS/ELEVATIONS ARE DERIVED FROM ARCHIVAL BUILDING PLANS & ARE INTENDED TO <br />REASONABLY REPRESENT EXISTING CONDITIONS. ACTUAL CONDITIONS MAY DEVIATE FROM THAT <br />SHOWN ON THE DRAWINGS. THE DEMO NOTES IDENTIFY SPECIFIC AREAS OF WORK, BUT MAY NOT BE <br />COMPLETE IN THE IDENTIFICATION OF ALL REMOVALS. THE CONTRACTOR SHALL VERIFY ACTUAL <br />CONDITIONS & COORDINATE DEMO WITH NEW WORK SO THAT DEMO IS COMPLETE. <br />8. EXISTING LIGHT FIXTURES AND ELECTRICAL COMPONENTS TO BE REMOVED EXCEPT AS NOTED. <br />REFER TO ELECTRICAL DEMOLITION PLANS FOR FULL EXTENT OF DEMOLITION AND FIXTURES BEING <br />REMOVED. <br />9. EXISTING FINISHES WILL BE REMOVED IN THEIR ENTIRETY WHERE INDICATED AND EXPOSED <br />SURFACES PREPARED FOR NEW FINISHES, <br />10. ALL WORK WHICH IS TO REMAIN SHALL BE PROTECTED FROM DAMAGE AND, iF DAMAGED, SHALL BE <br />REPAIRED AT NO COST TO THE OWNER. PROVIDE DUST ISOLATION & PROTECTION TO LIMIT DUST TO <br />AREAS OF WORK. <br />AREA OF DEMOLITION <br />WALLS TO REMAIN <br />ITEM TO BE REMOVED <br />ITEM TO REMAIN <br />KEYNOTE LEGEND <br />D5 REMOVE (E) WINDOWS AND CONCRETE WALL TO EXTENTS SHOWN. REMOVE INTERIOR, <br />INSULATION AND GYP BOARD ONLY TO SAME EXTENTS AS WALL REMOVAL OR AS REQUIRED <br />FOR STRUCTURAL RETROFIT. CONCRETE TO BE SAWCUT FOR SMOOTH, EVEN EDGE. REFER <br />TO DEMO ELEVATIONS D2.01 FOR ADDITIONAL INFORMATION. <br />D6 REMOVE (E) WINDOW. PRESERVE AND PROTECT OPENING FOR NEW WINDOW <br />REPLACEMENT, <br />D11 REMOVE (E) INTERIOR WALL AS INDICATED. <br />D12 REMOVE (E) INTERIOR DOOR AND FRAME, <br />D13 REMOVE (E) GYP/PLASTER FINISH TO EXPOSE WOOD COLUMN, TYP. USE CAUTION TO AVOID <br />DAMAGE TO COLUMN SURFACE AND STRUCTURAL INTEGRITY DURING DEMO. <br />D14 REMOVE (E) VINYL FLOORING AND RUBBER BASE. SCRAPE ADHESIVE AS REQUIRED AND <br />PREP FOR NEW FLOOR FINISH, <br />D15 REMOVE (E) CARPET OR CARPET TILE, PADDING, AND RUBBER BASE, SCRAPE ADHESIVE AS <br />REQUIRED AND PREP FOR NEW FLOOR FINISH, <br />D16 REMOVE (E) ACOUSTIC TILE CEILING, GRID, AND SUPPORT. REMOVE ALL CEILING MOUNTED <br />LIGHT FIXTURES AND HVAC REGISTERS, SEE ELECTRICAL AND MECHANICAL FOR <br />ADDITIONAL INFORMATION SEE FIRE PROTECTION DRAWINGS FOR SPRINKLER SYSTEM <br />REMOVAL. <br />D17 REMOVE (E) TOILET PART 1 T IONS. FILL HOLES AND PATCH AND/OR LEVEL CONCRETE AS <br />REQUIRED FOR SMOOTH, LEVEL SURFACE, <br />D18 REMOVE (E) REST ROOM ACCESSORIES INCLUDING BUT NOT LIMITED TO MIRRORS; GRAB <br />BARS, PAPER TOWEL, TOILET PAPER, SOAP, AND FEMININE HYGEINE DISPENSERS; AND <br />WASTE RECEPTACLES, <br />D19 REMOVE (E) PLUMBING FIX T URE(S) AS SHOWN SUPPLY AND DRAIN PIPING TO BE REMOVED <br />AND FILLED OR CAPPED AS DIRECTED IN PLUMBING DRAWINGS. <br />D20 REMOVE (E) PLUMBING PIPING AND FITTINGS, SALVAGE FOR RECYCLING OR PROPERLY <br />DISPOSE OF. SEE PLUMBING DEMO DRAWINGS, <br />D22 REMOVE (E) STAIR, LANDINGS, HAND AND GUARD RAILS, AND FRAMING IN THEIR ENTIRETY. <br />D23 REMOVE (E) HYDRAULIC ELEVATOR, STRUCTURE, AND MACHINERY. PROVIDE TEMPORARY <br />STRUCTURAL SUPPORT AS REQUIRED. REFER TO STRUCTURAL DRAWINGS FOR NEW <br />FRAMING THIS AREA. <br />D24 REMOVE ALL DATA AND COMMUNICATION WRING, EQUIPMENT, SUPPORT BRACKETS, AND <br />PLYWOOD BACKBOARDS, TYP, WIRING AND EQUIPMENT TO BE SALVAGED AND RECYCLED <br />OR PROPERLY DISPOSED OF. <br />D30 REMOVE (E) FLOOR STRUCTURE THIS AREA AS REQUIRED FOR NEW TWO-STORY OPENING, <br />PROVIDE TEMPORARY SUPPORT FOR FLOOR DECKING TO REMAIN UNTIL NEW STRUCTURE IS <br />COMPLETE. SEE STRUCTURAL, <br />D31 REMOVE (E) GLU-LAM PURLING THIS AREA AND SALVAGE FOR REUSE. WOOD MEMBERS TO <br />BE UNBOLTED FROM CONNECTION PLATES AND DISASSEMBLED WHERE POSSIBLE. IF <br />CUTTING IS REQUIRED, EDGES SHALL BE CLEAN AND PLUMB WITH MINIMAL DAMAGE TO <br />MEMBERS TO REMAIN, SEE STRUCTURAL FOR ADDITIONAL INFORMATION. <br />D32 REMOVE (E) RAISED FLOOR PANELS AND SUPPORT GRID, SALVAGE AND RECYCLE OR <br />DISPOSE OF PROPERLY, <br />D36 REMOVE (E) ACOUSTIC CEILING TILES, CEILING GRID AND SUPPORT TO REMAIN AND BE <br />REPAINTED. <br />D37 REMOVE (E) WOOD HANDRAILS AND BRACKETS, PATCH WALL SURFACE AS REQUIRED FOR <br />SMOO T H CONSISTENT FINISH, <br />D38 REMOVE (E) GUARDRAJUHANDRAILS AND WOOD TRIM AS REQUIRED FOR NEW PARTIAL <br />HEIGHT WALL INSTALLATION. PATCH WALLS AND OTHER SURFACES TO REMAIN AS <br />REQUIRED FOR SMOOTH CONSISTENT FINISH. <br />D39 SAWCUT AND REMOVE (E) CONCRETE FOR NEW WINDOW OPENING, REFERENCE DEMO <br />D5� 4'eREM AVE (E)CONC ATE SLAB 0 TFLOQR STRUCTUR FOR W M CHAN ALSHAF I . <br />IVEL 02 �. <br />`�1€Inc. <br />808 W �` t A� €�e, S1 UB <br />I� Rd2C4T <br />` , ," .2BT LiS . <br />a <br />I� <br />�� <br />z <br />1( s MAN 4 FLEENER I <br />' p er' , <br />I STAMP <br />CONSULTANT rt <br />TITLE <br /># DATE DESCRII <br />A 04/17/2020 PLAN RE\ <br />'TION <br />'ISIONS <br />REVISIONS <br />KE, MS WY, JG <br />DRAWN BY CHECK BY <br />100% ISSUE SET/BID SET <br />STATUS <br />04/17/2020 <br />DATE <br />328801 <br />PROJECT NUMBER <br />D1.02a <br />0 2020 OTAK, INC. <br />If this drawing is not 24"x 36" it has been <br />reducedleniarged. Scale accordingly. <br />