G F1 E1 ®l C1 B2 131 Al
<br />D2.t}1
<br />I I I 1 I I
<br />I 1 a
<br />I I I I I ! I
<br />4
<br />SCALE: 1/8" = V-0"
<br />bAA
<br />— lA
<br />MATCHLINE
<br />SEE1/D1.02b
<br />I
<br />DEMOLITION
<br />1. DASHED LINES INDICATE OBJECTS TO BE DEMOLISHED AND / OR SALVAGED.
<br />2. ITEMS SALVAGED FOR RE -USE SHALL BE SAFELY STORED AND PROTECTED FROM DAMAGE DURING
<br />CONSTRUCTION.
<br />3. EXISTING FURNITURE, DECORATIVE LIGHTING, & EQUIPMENT NOT TO BE RE -USED. CONTRACTOR TO
<br />BE RESPONSIBLE FOR SALVAGING FOR RECYCLING OR DISPOSAL AS REQUIRED.
<br />4. REFER TO THE REFLECTED CEILING PLANS FOR ADDITIONAL DEMO NOTES SPECIFIC TO THE EXISTING
<br />CEILING CONDITIONS.
<br />5. CONTRACTOR IS RESPONSIBLE FOR THE SAFE REMOVAL OF ANY AND ALL MATERIALS REFERRED TO
<br />IN THE MED-TOX 2007 HAZARDOUS BUILDING MATERIALS SURVEY. SHOULD THE CONTRACTOR
<br />ENCOUNTER ANY ADDITIONAL ASBESTOS MATERIALS, PCB'S, OR OTHER TOXIC SUBS T ANCES NOT
<br />NOTED IN THE SURVEY, THE CONTRACTOR SHOULD IMMEDIATELY REPORT THE FINDINGS IN WRITING
<br />TO THE BUILDING OWNER & TENANT, PRIOR TO CONTINUING WITH ANY WORK IN THE AREA. WORK
<br />SHALL NOT BE RESUMED EXCEPT BY WRITTEN AUTHORIZATION OR AGREEMENT FROM THE OWNER.
<br />6. EXISTING HVAC EQUIPMENT, PLUMBING, DRAIN & FIRE PROTECTION LINES TO BE DEMOLISHED
<br />EXCEPT AS NOTED. REFER TO MECHANICAL AND PLUMBING DEMOLITION DRAWINGS FOR FULL
<br />EXTENT OF DEMO. CONTRACTOR SHALL VERIFY EXISTING ITEMS TO REMAIN WITH
<br />ARCHITECT/MECHANICAL DESIGNER. COORDINATE WITH PROPERTY PRIOR TO INTERFERING WITH
<br />EXISTING UTILITIES.
<br />7, THE PLANS/ELEVATIONS ARE DERIVED FROM ARCHIVAL BUILDING PLANS & ARE INTENDED TO
<br />REASONABLY REPRESENT EXISTING CONDITIONS. ACTUAL CONDITIONS MAY DEVIATE FROM THAT
<br />SHOWN ON THE DRAWINGS. THE DEMO NOTES IDENTIFY SPECIFIC AREAS OF WORK, BUT MAY NOT BE
<br />COMPLETE IN THE IDENTIFICATION OF ALL REMOVALS. THE CONTRACTOR SHALL VERIFY ACTUAL
<br />CONDITIONS & COORDINATE DEMO WITH NEW WORK SO THAT DEMO IS COMPLETE.
<br />8. EXISTING LIGHT FIXTURES AND ELECTRICAL COMPONENTS TO BE REMOVED EXCEPT AS NOTED.
<br />REFER TO ELECTRICAL DEMOLITION PLANS FOR FULL EXTENT OF DEMOLITION AND FIXTURES BEING
<br />REMOVED.
<br />9. EXISTING FINISHES WILL BE REMOVED IN THEIR ENTIRETY WHERE INDICATED AND EXPOSED
<br />SURFACES PREPARED FOR NEW FINISHES,
<br />10. ALL WORK WHICH IS TO REMAIN SHALL BE PROTECTED FROM DAMAGE AND, iF DAMAGED, SHALL BE
<br />REPAIRED AT NO COST TO THE OWNER. PROVIDE DUST ISOLATION & PROTECTION TO LIMIT DUST TO
<br />AREAS OF WORK.
<br />AREA OF DEMOLITION
<br />WALLS TO REMAIN
<br />ITEM TO BE REMOVED
<br />ITEM TO REMAIN
<br />KEYNOTE LEGEND
<br />D5 REMOVE (E) WINDOWS AND CONCRETE WALL TO EXTENTS SHOWN. REMOVE INTERIOR,
<br />INSULATION AND GYP BOARD ONLY TO SAME EXTENTS AS WALL REMOVAL OR AS REQUIRED
<br />FOR STRUCTURAL RETROFIT. CONCRETE TO BE SAWCUT FOR SMOOTH, EVEN EDGE. REFER
<br />TO DEMO ELEVATIONS D2.01 FOR ADDITIONAL INFORMATION.
<br />D6 REMOVE (E) WINDOW. PRESERVE AND PROTECT OPENING FOR NEW WINDOW
<br />REPLACEMENT,
<br />D11 REMOVE (E) INTERIOR WALL AS INDICATED.
<br />D12 REMOVE (E) INTERIOR DOOR AND FRAME,
<br />D13 REMOVE (E) GYP/PLASTER FINISH TO EXPOSE WOOD COLUMN, TYP. USE CAUTION TO AVOID
<br />DAMAGE TO COLUMN SURFACE AND STRUCTURAL INTEGRITY DURING DEMO.
<br />D14 REMOVE (E) VINYL FLOORING AND RUBBER BASE. SCRAPE ADHESIVE AS REQUIRED AND
<br />PREP FOR NEW FLOOR FINISH,
<br />D15 REMOVE (E) CARPET OR CARPET TILE, PADDING, AND RUBBER BASE, SCRAPE ADHESIVE AS
<br />REQUIRED AND PREP FOR NEW FLOOR FINISH,
<br />D16 REMOVE (E) ACOUSTIC TILE CEILING, GRID, AND SUPPORT. REMOVE ALL CEILING MOUNTED
<br />LIGHT FIXTURES AND HVAC REGISTERS, SEE ELECTRICAL AND MECHANICAL FOR
<br />ADDITIONAL INFORMATION SEE FIRE PROTECTION DRAWINGS FOR SPRINKLER SYSTEM
<br />REMOVAL.
<br />D17 REMOVE (E) TOILET PART 1 T IONS. FILL HOLES AND PATCH AND/OR LEVEL CONCRETE AS
<br />REQUIRED FOR SMOOTH, LEVEL SURFACE,
<br />D18 REMOVE (E) REST ROOM ACCESSORIES INCLUDING BUT NOT LIMITED TO MIRRORS; GRAB
<br />BARS, PAPER TOWEL, TOILET PAPER, SOAP, AND FEMININE HYGEINE DISPENSERS; AND
<br />WASTE RECEPTACLES,
<br />D19 REMOVE (E) PLUMBING FIX T URE(S) AS SHOWN SUPPLY AND DRAIN PIPING TO BE REMOVED
<br />AND FILLED OR CAPPED AS DIRECTED IN PLUMBING DRAWINGS.
<br />D20 REMOVE (E) PLUMBING PIPING AND FITTINGS, SALVAGE FOR RECYCLING OR PROPERLY
<br />DISPOSE OF. SEE PLUMBING DEMO DRAWINGS,
<br />D22 REMOVE (E) STAIR, LANDINGS, HAND AND GUARD RAILS, AND FRAMING IN THEIR ENTIRETY.
<br />D23 REMOVE (E) HYDRAULIC ELEVATOR, STRUCTURE, AND MACHINERY. PROVIDE TEMPORARY
<br />STRUCTURAL SUPPORT AS REQUIRED. REFER TO STRUCTURAL DRAWINGS FOR NEW
<br />FRAMING THIS AREA.
<br />D24 REMOVE ALL DATA AND COMMUNICATION WRING, EQUIPMENT, SUPPORT BRACKETS, AND
<br />PLYWOOD BACKBOARDS, TYP, WIRING AND EQUIPMENT TO BE SALVAGED AND RECYCLED
<br />OR PROPERLY DISPOSED OF.
<br />D30 REMOVE (E) FLOOR STRUCTURE THIS AREA AS REQUIRED FOR NEW TWO-STORY OPENING,
<br />PROVIDE TEMPORARY SUPPORT FOR FLOOR DECKING TO REMAIN UNTIL NEW STRUCTURE IS
<br />COMPLETE. SEE STRUCTURAL,
<br />D31 REMOVE (E) GLU-LAM PURLING THIS AREA AND SALVAGE FOR REUSE. WOOD MEMBERS TO
<br />BE UNBOLTED FROM CONNECTION PLATES AND DISASSEMBLED WHERE POSSIBLE. IF
<br />CUTTING IS REQUIRED, EDGES SHALL BE CLEAN AND PLUMB WITH MINIMAL DAMAGE TO
<br />MEMBERS TO REMAIN, SEE STRUCTURAL FOR ADDITIONAL INFORMATION.
<br />D32 REMOVE (E) RAISED FLOOR PANELS AND SUPPORT GRID, SALVAGE AND RECYCLE OR
<br />DISPOSE OF PROPERLY,
<br />D36 REMOVE (E) ACOUSTIC CEILING TILES, CEILING GRID AND SUPPORT TO REMAIN AND BE
<br />REPAINTED.
<br />D37 REMOVE (E) WOOD HANDRAILS AND BRACKETS, PATCH WALL SURFACE AS REQUIRED FOR
<br />SMOO T H CONSISTENT FINISH,
<br />D38 REMOVE (E) GUARDRAJUHANDRAILS AND WOOD TRIM AS REQUIRED FOR NEW PARTIAL
<br />HEIGHT WALL INSTALLATION. PATCH WALLS AND OTHER SURFACES TO REMAIN AS
<br />REQUIRED FOR SMOOTH CONSISTENT FINISH.
<br />D39 SAWCUT AND REMOVE (E) CONCRETE FOR NEW WINDOW OPENING, REFERENCE DEMO
<br />D5� 4'eREM AVE (E)CONC ATE SLAB 0 TFLOQR STRUCTUR FOR W M CHAN ALSHAF I .
<br />IVEL 02 �.
<br />`�1€Inc.
<br />808 W �` t A� €�e, S1 UB
<br />I� Rd2C4T
<br />` , ," .2BT LiS .
<br />a
<br />I�
<br />��
<br />z
<br />1( s MAN 4 FLEENER I
<br />' p er' ,
<br />I STAMP
<br />CONSULTANT rt
<br />TITLE
<br /># DATE DESCRII
<br />A 04/17/2020 PLAN RE\
<br />'TION
<br />'ISIONS
<br />REVISIONS
<br />KE, MS WY, JG
<br />DRAWN BY CHECK BY
<br />100% ISSUE SET/BID SET
<br />STATUS
<br />04/17/2020
<br />DATE
<br />328801
<br />PROJECT NUMBER
<br />D1.02a
<br />0 2020 OTAK, INC.
<br />If this drawing is not 24"x 36" it has been
<br />reducedleniarged. Scale accordingly.