Laserfiche WebLink
PROJECT DESCRIPTION: <br />2-STORY OFFICE BUILDING / WAREHOUSE REMODEL <br />CONVENTIONAL SPREAD AND STRIP CONCRETE FOUNDATIONS <br />CONCRETE SLAB -ON -GRADE FIRST FLOOR <br />PRECASE CONCRETE TILT -UP PANELS <br />WOOD FRAMED 2ND FLOOR <br />WOOD FRAMED ROOF <br />GENERAL: <br />1. THE STRUCTURAL DRAWINGS ARE A PORTION OF THE CONTRACT DOCUMENTS AND <br />ARE INTENDED TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL, CIVIL, <br />MECHANICAL, AND ELECTRICAL DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE REQUIREMENTS FROM THE ENTIRE SET OF CONTRACT <br />DOCUMENTS (INCLUDING THE PROJECT SPECIFICATIONS) INTO THEIR WORK. <br />2. THESE GENERAL NOTES SUPPLEMENT THE PROJECT SPECIFICATIONS. REFER TO THE <br />PROJECT SPECIFICATIONS FOR <br />C S O ADDITIONAL REQUIREMENTS. <br />3. NOTES AND DETAILS ON THE STRUCTURAL DRAWINGS SHALL TAKE PRECEDENCE <br />OVER THE GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. <br />4. VERIFY ALL DIMENSIONS WITH THE ARCHITECTURAL DRAWINGS. <br />5. DETAILS ON THESE PLANS ARE INTENDED TO DEPICT THE GENERAL CONSTRUCTION <br />METHODS FOR THIS STRUCTURE. CONNECTIONS, DETAILS AND CONDITIONS NOT <br />SPECIFICALLY SHOWN THAT ARE SIMILAR TO THOSE THAT ARE SPECIFIED SHALL BE <br />ASSUMED ONE AND THE SAME. IF QUESTIONS REGARDING THE APPLICATION OF <br />DETAILS ARE ENCOUNTERED, NOTIFY THE ARCHITECT/ENGINEER FOR CLARIFICATION <br />IN A TIMELY MANNER PRIOR TO BID OPENING. <br />CODE REQUIREMENTS: <br />1. CONFORM TO THE 2015 INTERNATIONAL BUILDING CODE (IBC) WITH WASHINGTON <br />STATE AMENDMENTS. <br />2. ALL REFERENCE TO OTHER CODES AND STANDARDS (ACI, ASTM, ETC.) SHALL BE FOR <br />THE EDITIONS NOTED IN CHAPTER 35 OF THE IBC, <br />TEMPORARY CONDITIONS: <br />1. THE STRUCTURE HAS BEEN DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. <br />THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING <br />AND/OR SUPPORT REQUIRED AS A RESULT OF THE CONTRACTOR'S CONSTRUCTION <br />METHODS AND/OR SEQUENCES. <br />2. CONTRACTOR'S CONSTRUCTION METHODS AND/OR SEQUENCES SHALL RECOGNIZE <br />AND CONSIDER THE EFFECTS OF THERMAL MOVEMENTS OF STRUCTURAL ELEMENTS <br />(DURING THE CONSTRUCTION PERIOD. <br />EXISTING CONDITIONS: <br />1. ALL EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONS SHALL BE FIELD VERIFIED. <br />THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY SIGNIFICANT <br />DISCREPANCIES FROM CONDITIONS SHOWN ON THE DRAWINGS. <br />DESIGN CRITERIA: <br />1. DESIGN WAS BASED ON THE STRENGTH AND DEFLECTION CRITERIA OF THE IBC. IN <br />ADDITION TO THE DEAD LOADS, THE FOLLOWING LOADS AND ALLOWANCES WERE <br />USED FOR DESIGN, WITH LIVE LOADS (LL) REDUCED IN ACCORDANCE WITH THE IBC: <br />DESIGN CRITERIA <br />GEOTECHNICAL CRITERIA <br />DESIGN BASED ON <br />GEOENGINEERS, INC. <br />GEOTECHNICAL REPORT BY: <br />DATED SEPTEMBER 3, 2019 <br />ALLOWABLE SOIL BEARING <br />3,000 PSF (INCREASE 33 PERCENT FOR LOAD COMBINATIONS <br />PRESSURE <br />INCLUDING WIND AND SEISMIC) <br />_ LIVE LOAD CRITERIA <br />FLOOR LIVE LOADS <br />UNIFORM LOAD (PSF) <br />CONCENTRATED LOAD <br />(LBS) <br />OFFICES <br />50 PSF <br />2000 <br />VERTICAL FLOOR <br />DEFLECTION <br />L/360 (LIVE LOAD) IBC 20`15 TABLE 1604.3 <br />(CLADDING DESIGN) <br />CORRIDORS AND STAIRS <br />100 <br />2000 <br />ASSEMBLY AREAS, RETAIL <br />100 <br />2000 <br />STORAGE (LIGHT) <br />125 <br />2000 <br />VERTICAL FLOOR <br />DEFLECTION <br />L/360 (LIVE LOAD), REF IBC TABLE 1604.3 <br />(CLADDING DESIGN) <br />NOTES: <br />1. LIVE LOADS REDUCED, REF IBC 1607A0 <br />2. MEMBER DESIGNED FOR THE MORE CRITICAL OF THE <br />UNIFORM OR CONCENTRATED LOAD. <br />SNOW CRITERIA <br />DESIGN ROOF SNOW LOAD <br />25 PSF MINIMUM IN ACCORDANCE WITH CITY OF EVERETT <br />SNOW DRIFT <br />PER IBC AS SHOWN ON PLANS (IN ADDITION TO DESIGN ROOF <br />SNOW LOAD, NOT FLAT ROOF SNOW LOAD) <br />GROUND SNOW LOAD <br />P <br />s = 25 PSF IN ACCORDANCE WITH CITY OF EVERETT <br />FLAT ROOF SNOW LOAD <br />P f = 25 PSF <br />SNOW EXPOSURE FACTOR <br />C = 1.0 <br />� <br />SNOW LOAD IMPORTANCE <br />FACTOR <br />I 1.0 <br />THERMAL FACTOR <br />C t = 1.0 <br />-- <br />WIND CRITERIA <br />MAIN WIND FORCE RESISTING <br />_ - <br />SYSTEM <br />110 MPH BASIC WIND SPEED (3-SECOND GUST ) <br />COMPONENTS AND CLADDING <br />110 MPH BASIC WIND SPEED (3-SECOND GUST) <br />EXPOSURE CATEGORY <br />B <br />GUST/INTERNAL PRESSURE <br />GCPi a +/- 0.13 <br />SEISMIC CRITERIA <br />_ <br />DISK CATEGORY <br />11 <br />SITE CLASS <br />C <br />ANALYSIS PROCEDURE <br />EQUIVALENT LATERAL FORCE, REF ASCE 7-10 SECTION 13 <br />(VIEW) <br />IMPORTANCE FACTOR <br />1, = 1.0 <br />SEISMIC DESIGN CATEGORY <br />D <br />MCE SPECTRAL <br />ACCELERATIONSS <br />1.444 <br />S m 0.559 <br />$ <br />1 <br />SITE COEFFICIENTS <br />F �, = 1.0 <br />F V ® 1.3 <br />DESIGN SPECTRAL <br />= 0.963 <br />S = 0.485 <br />os <br />D1 <br />NORTH -SOUTH DIRECTION <br />EAST -WEST DIRECTION <br />SEISMIC LOAD RESISTING <br />INTERMEDIATEPRECAST T <br />C S <br />INTERMEDIATE PRECAST <br />SYSTEM/! <br />CONCRETE SHEAR WALLS <br />CONCRETE SHEAR WALLS <br />RESPONSE MODIFICATION <br />FACTOR <br />R = 4,0 <br />R ; 4,0 <br />SEISMIC RESPONSE <br />COEFFICIENT <br />C = 0.241 <br />C = 0.241 <br />s <br />s <br />DESIGN BASE SHEAR <br />V = 1100 KIPS <br />V = 1100 KIPS I <br />REDUNDANCY FACTOR <br />rho ® 1.0 rho -- 1.0 <br />ANALYSIS PROCEDURE <br />LINEAR STATIC PROCEDURE, REF ASCE 41-13 <br />(EXISTING) <br />PERFORMANCE OBJECTIVE <br />BSE-1E <br />TARGET BUILDING <br />STRUCTURALPERFORMANCE <br />LEVEL <br />S-3 (LIFE SAFETY) <br />TARGET BUILDING <br />NONSTRUCTURAL <br />PERFORMANCE LEVEL <br />3-C <br />SPECTRAL ACCELERATIONS <br />Ss = 0.452 <br />S, = 0.168 <br />SITE COEFFICIENTS <br />F a = 1.438 <br />F V = 2.130 <br />DESIGN SPECTRAL <br />S = 0.650 <br />S = 0.358 <br />ACCELERATIONS <br />xs <br />x1 <br />DESIGN BASE SHEAR <br />V = 4145 KIPS <br />V = 4145 KIPS <br />STRUCTURAL OBSERVATION: <br />1. THE STRUCTURAL ENGINEER OF RECORD (SER) WILL PERFORM STRUCTURAL <br />OBSERVATIONS BASED ON THE REQUIREMENTS OF THE IBC AT THE STAGES OF <br />CONSTRUCTION LISTED BELOW. THE CONTRACTOR SHALL PROVIDE SUFFICIENT NOTICE <br />AND ACCESS FOR THE SER TO PERFORM THESE OBSERVATIONS: <br />STRUCTURAL OBSERVATIONS <br />CONSTRUCTION PHASE <br />OBSERVATION <br />COMMENTS <br />BY SER <br />PRIOR TO FIRST FOUNDATION CONCRETE <br />X <br />REF. FOOTNOTE A, B, C <br />POUR <br />PRIOR TO FIRST CONCRETE SHEAR WALL <br />X <br />REF. FOOTNOTE A, B, C <br />POUR <br />AT COMPLETION OF HORIZONTAL ROOF AND <br />X <br />REF. FOOTNOTE A, B <br />FLOOR DIAPHRAGMS PRIOR TO COVERING <br />AT COMPLETION OF BUILDING STRUCTURAL <br />SYSTEM, PRIOR TO COVERING OF STRUCTURAL <br />X <br />REF. FOOTNOTE A, B <br />ELEMENTS <br />AS REQUIRED TO ADDRESS STRUCTURAL <br />- _X <br />REF. FOOTNOTE A, B <br />ISSUES <br />A. STRUCTURAL OBSERVATIONS ARE INTENDED TO VERIFY GENERAL CONFORMANCE <br />WITH THE STRUCTURAL DRAWINGS. SPECIAL INSPECTIONS AND TESTING ARE STILL <br />REQUIRED. <br />B. A FIELD REPORT WILL BE SUBMITTED TO THE BUILDING DEPARTMENT FOLLOWING <br />EACH VISIT. <br />C. STRUCTURAL OBSERVATION TO OCCUR AFTER THE REINFORCING STEEL HAS BEEN <br />INSTALLED. <br />SPECIAL INSPECTION AND TESTING: <br />1. SPECIAL INSPECTION WILL BE PROVIDED BY R BAREQUIREMENTS OF THE IBC AS SUMMARIZED IN THE SPECIAL INSPECTION AND TESTING <br />PROGRAM ON SHEET SO.03. THE <br />RACTOR SHALL PROVIDE SUFFICIENT NOTICE <br />AND ACCESS FOR THE SED ON THE <br />SUBMITTALS: <br />1. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO THE FABRICATION <br />AND CONSTRUCTION OF ALL STRUCTURAL ITEMS INCLUDING THE FOLLOWING:. <br />SUBMITTALS <br />ITEM <br />SUBMITTAL <br />(A, D) <br />DEFERRED <br />SUBMITTAL <br />(B, D) <br />COMMENTS <br />CONCRETE MIX DESIGNS <br />X <br />CONCRETE REINFORCEMENT <br />X <br />i <br />REINFORCING STEEL MILL <br />CERTS <br />X <br />ACl/CRSI ADHESIVE ANCHOR <br />INSTALLER CERTIFICATIONS <br />X <br />CONCRETE ANCHORAGES <br />X <br />EMBEDDED STEEL ITEMS <br />X <br />STRUCTURAL STEEL MILL <br />CERTS <br />X <br />STRUCTURALSTEEL <br />X <br />STEEL WELDING PROCEDURES <br />X <br />STEELFASTENERS <br />X <br />WELDER CERTIFICATIONS <br />X <br />GLUED LAMINATED MEMBERS <br />X <br />LIGHT GAUGE METAL FRAMING <br />(INCLUDING WALLS, SOFFITS, <br />CEILINGS, OPENING FRAMING, <br />AND CONNECTIONS, ETC.) <br />X <br />l <br />C X <br />C <br />FOOTNOTE "E„ <br />ROOF TIEOFFS <br />X <br />X <br />FOOTNOTE "E" <br />_ <br />MECHANICAL SCREENS <br />- X , - <br />X - <br />FOOTNOTE "E" - <br />ROOF LADDERS AND SHIPS <br />LADDERS <br />X <br />X <br />FOOTNOTE "E„ <br />SKYLIGHTS, CANOPIES AND <br />AWNINGS <br />X <br />X <br />STAIRS AND RAILINGS <br />X <br />X <br />MEP ANCHORAGE AND <br />BRACING <br />X <br />X <br />FOOTNOTE R"C" <br />A. IF THE SHOP DRAWINGS DIFFER FROM OR ADD TO THE DESIGN OF THE <br />STRUCTURAL DRAWINGS, THEY SMALL BEAR THE SEAL AND SIGNATURE OF A <br />PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS <br />LOCATED. ANY MODIFICATIONS TO THE STRUCTURAL DRAWINGS SHALL BE <br />SUBMITTED TO THE ARCHITECT AND ARE SUBJECT TO REVIEW AND ACCEPTANCE <br />BY THE STRUCTURAL ENGINEER OF RECORD. <br />B. DESIGN DRAWINGS, SHOP DRAWINGS, AND CALCULATIONS FOR THE DESIGN AND <br />FABRICATION OF ITEMS THAT ARE DESIGNED BY OTHERS SHALL BEAR THE SEAL <br />AND SIGNATURE OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE <br />WHERE THE PROJECT IS LOCATED. CALCULATIONS SHALL BE INCLUDED FOR ALL <br />CONNECTIONS TO THE STRUCTURE CONSIDERING LOCALIZED EFFECTS ON <br />STRUCTURAL ELEMENTS INDUCED BY THE CONNECTION LOADS. DESIGN SHALL BE <br />(BASED UPON THE REQUIREMENTS OF THE IBC AND AS NOTED UNDER "DESIGN <br />CRITERIA." <br />C. THE CONTRACTOR SHALL COORDINATE THE VERTICAL AND SEISMIC RESTRAINTS <br />OF MECHANICAL, ELECTRICAL, AND PLUMBING EQUIPMENT, MACHINERY, AND <br />ASSOCIATED PIPING WITH THE STRUCTURE. CONNECTIONS TO THE STRUCTURE <br />SHALL CONFORM TO ASCE 7-10 CHAPTER 13 AND BE DESIGNED BY AN <br />PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS <br />LOCATED. <br />D. FIELD ENGINEERED DETAILS DEVELOPED BY THE CONTRACTOR THAT DIFFER FROM, <br />OR ADD TO, THE STRUCTURAL DRAWINGS SHALL BEAR THE SEAL AND SIGNATURE <br />OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT <br />IS LOCATED AND SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO <br />CONSTRUCTION. ANY SUCH DETAILS ARE SUBJECT TO REVIEW AND ACCEPTANCE <br />BY THE STRUCTURAL ENGINEER OF RECORD. <br />E. THE DELEGATED DESIGNER SHALL, IN CONJUNCTION WITH THE GENERAL <br />CONTRACTOR, COORDINATE THE VERTICAL AND SEISMIC RESTRAINTS AND <br />LOADING OF EQUIPMENT WITH THE STRUCTURE. CONNECTIONS TO THE <br />STRUCTURE SHALL CONFORM TO IBC AND ASCE 7 AND BE DESIGNED BY A <br />PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS <br />LOCATED, <br />F. SHOP DRAWINGS SHALL BE GENERATED AND ORIGINATE FROM THE CONTRACTOR. <br />STRUCTURAL AUTOCADIREVIT BACKGROUNDS WILL NOT BE RELEASED BY FE AND <br />MAY NOT BE USED FOR THE GENERATION OF SHOP DRAWINGS. IT IS THE <br />CONTRACTORS RESPONSIBILITY TO GENERATE THEIR SHOP DRAWINGS. <br />FOUNDATIONS: <br />1. FOUNDATION SIZES ARE BASED UPON A MAXIMUM TOTAL LOAD BEARING SOIL PRESSURE <br />AS NOTED IN DESIGN CRITERIA FOR BEARING ON NATIVE SOILS/COMPACTED FILL, AS <br />RECOMMENDED BY THE GEOTECHNICAL REPORT. <br />2. ALL FOOTINGS SHALL BE A MINIMUM OF 18 INCHES BELOW FINAL GRADES. <br />3. ALL DISTURBED SOIL SHALL BE REMOVED BY HAND OPERATION FROM FOOTING <br />EXCAVATIONS TO NEAT LINES AND REPLACED WITH ENGINEERED FILL IF NECESSARY. <br />4. THE CONTRACTOR SHALL REVIEWALL GEOTECHNICAL ENGINEER RECOMMENDATIONS <br />PRIOR TO THE COMMENCEMENT OF ANY SITEWORK. <br />5. STRUCTURAL FILL MATERIALS, PLACEMENT, AND COMPACTION REQUIREMENTS SHALL BE <br />IN ACCORDANCE WITH THE GEOTECHNICAL REPORT. <br />6. BOTTOM OF FOOTINGS SHALL BE STEPPED FROM ELEVATION TO ELEVATION AT 2' 0" <br />HORIZONTAL TO V-0" VERTICAL STEPS. <br />7. PLACEMENT OF ALL FILL SHALL BE OBSERVED AND TESTED FOR RELATIVE COMPACTION <br />BY A QUALIFIED TECHNICIAN UNDER THE GUIDANCE OF THE GEOTECHNICAL ENGINEER. <br />MINIMUM TESTING FREQUENCY SHALL BE ESTABLISHED BY THE GEOTECHNICAL ENGINEER. <br />8. THE CONTRACTOR SHALL NOTIFY THE GEOTECHNICAL ENGINEER PRIOR TO <br />COMMENCEMENT OF FILLING OPERATIONS. <br />9. ALL GENERAL EXCAVATIONS AND FOOTINGS SH <br />ALL BE INSPECTED AND APPROVED PRIOR <br />TO THE PLACEMENT OF ANY SOIL BACKFILL AND/OR CONCRETE. <br />10. ALL FILL, BACKFILL AND COMPACTION ACTIVITIES, PARTICULARLY DURING WET WEATHER <br />CONDITIONS, SHALL FOLLOW RECOMMENDATIONS OF GEOTECHNICAL ENGINEER. <br />11. GROUND ADJACENT TO THE FOUNDATION SHALL BE SLOPED AWAY FROM THE BUILDING AT <br />LEAST 5 PERCENT SLOPE FOR A MINIMUM DISTANCE OF 10 FEET FROM THE BUILDING. <br />NOTIFY FOR IF CONDITIONS VARY. <br />CONCRETE: <br />1. ALL CONCRETE WORK SHALL CONFORM TO "ACI 313--BUILDING CODE REQUIREMENTS FOR <br />STRUCTURAL CONCRETE" AND CHAPTER 19 OF THE INTERNATIONAL BUILDING CODE. <br />2. CONCRETE STRENGTHS SHALL BE VERIFIED BY STANDARD 28-DAY CYLINDER TESTS PER <br />ASTM C39, UNLESS NOTED OTHERWISE, AND SHALL BE AS FOLLOWS: <br />CONCRETE STRENGTHS <br />WATER - <br />ENTRAINED <br />DESCRIPTION <br />f"c (PSI) <br />CEMENT <br />RATIO BY <br />AIR OTHER <br />WEIGHT <br />(PERCENT) <br />FOOTINGS, STEMWALLS <br />1 4,000 <br />0.53 <br />2 +/- 1.5 <br />INTERIOR WALLS <br />4,000 <br />0.45 <br />EXTERIOR WALLS <br />( 4,000 <br />0.45 <br />6 +/- 1.5 <br />INTERIOR SLAB -ON -GRADE <br />4,000 <br />0,48 <br />SEE NOTE E <br />NOTES: <br />A. VERIFY WATERICEMENT RATIO WITH FLOOR COVERING MANUFACTURER FOR <br />CONCRETE FLOORS WITH MOISTURE SENSITIVE FLOOR COVERINGS. <br />B. CONCRETE MIXES SHALL BE NORMAL WEIGHT AND CONTAIN PORTLAND CEMENT <br />CONFORMING TO ASTM C150 FOR TYPE 1, OR TYPE 11. <br />C. AIR ENTRAINING AGENT SHALL CONFORM TO ASTM C260. <br />D. COLUMNS THAT ARE AN INTEGRAL PART OF A WALL SHALL HAVE CONCRETE <br />STRENGTH AS REQUIRED FOR COLUMNS, <br />E. SHRINKAGE RATE, AS DETERMINED BY ASTM C157, OF CONCRETE SHALL NOT EXCEED <br />0.045 PERCENT AT 28 DAYS. USE A SHRINKAGE REDUCING ADMIXTURE TO ACHIEVE <br />THIS VALUE, IF REQUIRED. <br />F. LIMITS ON CEMENTITIOUS MATERIALS FOR CONCRETE ASSIGNED TO EXPOSURE <br />CLASS F3: <br />CEMENTITIOUS MATERIALS <br />MAXIMUM PERCENT OF TOTAL <br />CEMENTITIOUS MATERIALS BY MASS <br />FLY ASH OR OTHER POZZOLANS <br />25 <br />CONFORMING TO ASTM C618 <br />SLAG CEMENT CONFORMING TO ASTIVI <br />50 <br />C989 <br />SILICA FUME CONFORMING TO ASTM <br />10 <br />C1240 <br />-- -^- <br />TOTAL OF FLY ASH OR OTHER <br />35 --- -- <br />POZZOLANS AND SILICA FUME <br />TOTAL OF FLY ASH OR OTHER <br />POZZOLANS, SLAG CEMENT, AND SILICA <br />50 <br />FUME <br />3. MINIMUM CEMENT CONTENT PER CUBIC YARD SHALL BE AS FOLLOWS: <br />MINIMUM CEMENT CONTENT <br />f c (PSI) MINIMUM CEMENT CONTENT PER CUBIC <br />YARD <br />3,000 _ 470 LBS. <br />4,000 550 LBS, <br />5,000 630 LBS. <br />A. FLYASH CONFORMING TO ASTM C618 "TYPE F," OR "TYPE; C" MAY BE USED TO REPLACE <br />UP TO 20 PERCENT OF THE CEMENT CONTENT, PROVIDED THAT THE MIX STRENGTH IS <br />SUBSTANTIATED BY TEST DATA. <br />4. THE CONTRACTOR SHALL SUBMIT CONCRETE MIX DESIGNS, ALONG WITH TEST DATA <br />COMPLIANT WITH ACI-318 CHAPTER 5, A MINIMUM OF TWO WEEKS PRICER TO PLACING <br />CONCRETE. <br />5. NO WATER MAY BE ADDED TO CONCRETE IN THE FIELD UNLESS IT CONFORMS TO THE <br />APPROVED MIX DESIGN AND IS SPECIFICALLY APPROVED IN WRITING BY THE CONCRETE <br />SUPPLIER. <br />6. A WATER REDUCING ADMIXTURE CONFORMING TO ASTM C494 USED IN STRICT <br />CONFORMANCE WITH THE MANUFACTURER'S RECOMMENDATIONS SHALL BE <br />INCORPORATED INTO CONCRETE MIX DESIGNS. A HIGH RANGE WATER REDUCING <br />ADMIXTURE CONFORMING TO ASTM C494 "TYPE F, OR TYPE "G" MAY BE USED IN <br />CONCRETE MIXES PROVIDED THAT THE SLUMP DOES NOT EXCEED 10-INCHES. <br />7. CONCRETE SMALL BE PLACED IN ONE CONTINUOUS OPERATION WHEREVER PRACTICAL. <br />VERTICAL CONSTRUCTION JOINTS IN WALLS SHALL BE LOCATED MIDWAY BETWEEN <br />COLUMNS OR PILASTERS. <br />8. SLEEVES, OPENING, CONDUITS, AND OTHER EMBEDDED ITEMS NOT SHOWN ON THE <br />STRUCTURAL DRAWINGS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER PRIOR TO <br />PLACING CONCRETE. CONDUITS EMBEDDED IN SLABS SHALL NOT BE LARGER IN OUTSIDE <br />DIMENSION THAN ONE-THIRD THE THICKNESS OF THE SLAB AND SHALL NOT BE SPACED <br />CLOSER THAN THREE DIAMETERS ON -CENTER. <br />9. THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR THE LAYOUT OF CONSTRUCTION <br />AND CONTROL JOINTS FOR CONCRETE SLABS -ON -GRADE. THE JOINTS SHALL BE LOCATED <br />AT MAXIMUM 12'-0" ON -CENTER EACH WAY FORMING RECTANGLES WITH A LENGTH TO <br />WIDTH RATIO NOT EXCEEDING 1.5 IN ANY DIRECTION. CONTROL JOINTS SHALL INTERSECT <br />AT COLUMN BLOCKOUTS, AT ENDS OF BEARING WALLS, AND AT ALL RE-ENTRANT <br />CORNERS IN THE SLAB. <br />10. PROVIDE VERTICAL EXPANSION JOINTS IN CONTINUOUS CONCRETE ASSEMBLIES AND <br />WALLS SUCH THAT THE DISTANCE BETWEEN JOINTS DOES NOT EXCEED THE LESSER OF A <br />LENGTH -TO -HEIGHT RATIO OF 3.5 OR 40-FEET. REFERENCE ARCHITECTURAL DRAWINGS <br />FOR THE LOCATION OF EXPANSION JOINTS. <br />11. ALL BOLTS AND/OR ANCHOR RODS EMBEDDED INTO CONCRETE SHALL CONFORM TO ASTM <br />SPECIFICATION F1554 GRADE 36 UNLESS NOTED OTHERWISE ON THE STRUCTURAL <br />DRAWINGS. <br />12. ANCHOR RODS ARE TO BE LOCATED BY MEANS OF TEMPLATE. ANCHOR RODS SHALL NOT <br />BE HAND SET, OR WET SET. <br />13. ANCHOR RODS AND EMBEDDED ITEMS SHALL BE SET IN ACCORDANCE WITH THE AISC <br />CODE OF STANDARD PRACTICE SECTION 7.5. <br />14. WHERE NEW CONCRETE IS PLACED AGAINST EXISTING CONCRETE, THE EXISTING <br />CONCRETE SURFACE SHALL BE CLEANED AND ROUGHENED TO A (MINIMUM 1/4" <br />AMPLITUDE. <br />15. PROVIDE 3/4" CHAMFERS ON ALL EXPOSED CONCRETE EDGES, UNLESS NOTED <br />OTHERWISE. <br />16. PREPARATION, CONSTRUCTION AND PROTECTION OF CONCRETE DURING COLD WEATHER <br />OR HOT WEATHER SHALL CONFORM TO ACI 318 5.12, 5.13 AND ACI 306R AND 305R. <br />SHOTCRETE: <br />1. SHOTCRETE SHALL CONFORM TO ACI 506R-05, ACI 506.2-95, AND SECTION 1910 OF THE IBC. <br />2. PRE -CONSTRUCTION TESTS SHALL BE PERFORMED PER IBC SECTION 1910.5. <br />3. WET OR DRY MIX MAY BE USED AT THE CONTRACTORS DISCRETION. <br />4. THE CONCRETE SHALL ACHIEVE A MINIMUM OF 2,000 PSI AT 3 DAYS AND 4,000 PSI AT 26 <br />DAYS. <br />5. SHOTCRETE SHALL NOT BE PLACE BELOW 40 DEG. F OR ABOVE 100 DEGREES F. <br />6. DAMPEN CONCRETE AND MASONRY SURFACES BEFORE APPLICATION, DRY TO A <br />,SATURATED -SURFACE -DRY (SSD) CONDITION FOR APPLICATION. EXCESSIVELY WET <br />SURFACES ARE NOT PERMITTED. <br />7. APPLY WATER CONTROL MEASURES TO WET EARTH SURFACES. <br />8. FOR INSTALLATIONS ON ROUGHENED CONCRETE OR ROCK SURFACES, SAND BLAST TO <br />REMOVE ALL LOOSE MATERIAL. <br />9, TIE REINFORCING TO PREVENT VIBRATION DURING APPLICATION. <br />10. USE ROUND AGGREGATE FOR SHOTCRETE MIX. <br />11. INSTALL WELDED WIDE FABRIC OVER ENTIRE SURFACE. USE NON -CONTACT LAPS AT ALL <br />WWF SPLICES. <br />REINFORCING STEEL- <br />1. REINFORCING STEEL SHALL BE DETAILED, FABRICATED, AND PLACED IN ACCORDANCE TO ®ACI 318- <br />BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" AND "ACI 315-MANUAL OF <br />STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES." <br />2. ALL REINFORCING STEED SHALL CONFORM TO THE FOLLOWING SPECIFICATIONS AND GRADES <br />UNLESS NOTED OTHERWISE ON THE STRUCTURAL DRAWINGS: <br />REINFORCING SPECIFICATIONS AND GRADES <br />USE ASTM SPECIFICATION AND <br />GRADE <br />SMOOTH WELDED WIRE FABRIC ASTM A1064 <br />CONCRETE SHEAR WALL REINFORCEMENT ASTM A706*, GRADE 60 <br />ALL OTHER REINFORCEMENT ASTM A615, GRADE 60 <br />*ASTM A706 REBAR IN THE ABOVE USES IS PERMITTED TO BE REPLACED WITH ASTM A615 REBAR OF <br />THE SAME GRADE IF ALL OF THE FOLLOWING ARE MET: <br />A) THE ACTUAL YIELD STRENGTH BASED ON MILL TESTS DOES NOT EXCEED fy BY MORE THAN 18,000 <br />PSI <br />B) THE RATIO OF THE ACTUAL TENSILE STRENGTH TO THE ACTUAL YIELD STRENGTH IS NOT LESS <br />THAN 1.25 <br />C) SUPPORTING MILL CERTS OF THE REBAR SUPPLIED ON THE PROJECT IS PROVIDED FOR REVIEW <br />3. REINFORCING STEEL TO BE WELDED SHALL CONFORM TO ASTM A706. WELDING OF REINFORCING <br />STEEL SHALL CONFORM TO AWS D1.4. ALL WELDING SHALL BE DONE BY AWS CERTIFIED WELDERS <br />USING LOW HYDROGEN E70XX ELECTRODES. <br />4. REINFORCING STEEL SHALL BE SECURELY TIED IN -PLACE WITH #r16 ANNEALED IRON WIRE. BARS IN <br />BEAMS, SLABS, AND FOUNDATIONS SHALL BE SUPPORTED ON WELL -CURED CONCRETE BLOCKS, <br />OR APPROVED METAL CHAIRS, AS SPECIFIED BY THE "CRSI MANUAL OF STANDARD PRACTICE," <br />MSP-1. <br />5. ALL REINFORCEMENT SHALL BE FREE OF LOOSE MILL AND RUST SCALE, OIL, DIRT, OR COATINGS OF <br />ANY KIND THAT REDUCE THE POND STRENGTH TO THE CONCRETE. <br />6. REINFORCEMENT STEEL SHALL NOT BE DISPLACED OR ALTERED FOR THE CONVENIENCE OF OTHER <br />TRADES UNLESS APPROVED BY THE STRUCTURAL ENGINEER OF RECORD. <br />7. "WET SETTING" OF REINFORCING STEEL, ANCHOR RODS, EMBEDDED PLATES AND INSERTS IS NOT <br />PERMITTED. <br />8. ALL REINFORCEMENT SHALL BE CONTINUOUS WITH ADEQUATE LAP LENGTHS AT SPLICE <br />LOCATIONS. <br />9. MINIMUM LAP OF WELDED WIRE FABRIC SHALL BE 12". <br />10. THE FOLLOWING MINIMUM LAP SPLICE LENGTHS SHALL BE PROVIDED FOR ALL REINFORCING STEEL: <br />TYPICAL LAP SPLICE SCHEDULE (IN) <br />3,000 PSI <br />4,000 PSI <br />5,000 PSI <br />BAR SIZE <br />TOP BARS <br />OTHER BARS <br />TOP BARS <br />OTHER BARS <br />TOP BARS <br />OTHER BARS <br />3 <br />28 <br />22 <br />24 <br />19 - <br />22 <br />17 <br />#I'4 <br />37 <br />29 <br />32 <br />25 <br />29 <br />22 <br />95 <br />47 <br />36 <br />40 <br />31 <br />36 <br />2 <br />#6 <br />56 <br />43 <br />46 <br />37 <br />43 <br />33 <br />#7 <br />81 <br />63 <br />70 <br />54 <br />63 <br />49 <br />#8 <br />93 <br />72 <br />80 <br />62 <br />72 <br />55 <br />NU I L6: <br />A. FOR CENTER -TO -CENTER SPACING LESS THAN FOUR TIMES THE BAR DIAMETER, MULTIPLY THE <br />ABOVE VALUES BY A FACTOR OF 1 A. <br />B. TABLE VALUES APPLY FOR CLEAR COVER GREATER THAN OR EQUAL TO 1-1/2". CONTACT <br />ENGINEER OF RECORD IF CONDITIONS VARY. <br />C. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12°" OF CONCRETE CAST BELOW THE BAR. <br />D. VALUES ARE FOR UNCOATED BARS. <br />11. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR ALL REINFORCING STEEL: <br />MINIMUM CONCRETE COVER (CAST -III -PLACE) <br />USE <br />COVER <br />BEAM, JOIST AND COLUMN BARS <br />1-1/2" (TO STIRRUPS, OR TIES) <br />SLAB BARS <br />1'" <br />INTERIOR WALL FACE <br />S ES <br />(NOT EXPOSED TO EARTH, OR WEATHER) <br />3/4'° (#11 AND SMALLER) <br />EXTERIOR WALL FACES <br />(EXPOSED TO EARTH, OR WEATHER) <br />1-1/2" (#5 AND SMALLER) <br />2" (#6 AND LARGER) <br />CONCRETE CAST AGAINST EARTH <br />3" <br />12. UNLESS NOTED OTHERWISE ON THE STRUCTURAL DRAWINGS, REINFORCE ALL CONCRETE WALLS <br />AS FOLLOWS: <br />TYPICAL CONCRETE WALL REINFORCING <br />-LOCATION <br />WALL SIZE <br />(HORIZONTAL <br />BARS <br />VERTICAL BARS <br />- <br />6" <br />74 AT 16" OC <br />#4 AT 16" OC <br />AT CL OF WALL <br />8" <br />#4 AT 12" OC <br />#4 AT 12" OC <br />AT CL OF WALL <br />10" <br />94 AT 18" CC <br />#4 AT 18" OC <br />t___#4AT_16"OC <br />AT EACH FACE <br />12" <br />AT 16" OC <br />AT EACH FACE <br />13. CONTINUE HORIZONTAL WALL BARS THROUGH PILASTERS, COLUMNS AND INTERSECTING WALLS. <br />14, PROVIDE HOOKED FOOTING DOWELS OF THE SAME SIZE AND SPACING AS THE VERTICAL WALL <br />REINFORCEMENT. LAP SPLICE DOWELS TO THE VERTICAL WALL REINFORCEMENT AND TERMINATE <br />WITH STANDARD 90 DEGREE HOOK INTO THE FOOTING WITH 3" CLR TO BOTTOM OF FOOTING. <br />15, AT WALL OPENINGS, PROVIDE A MINIMUM OF TWO #5 BARS OVER, UNDER, AND AT THE SIDES OF <br />THE OPENING. EXTEND THESE BARS A LAP DISTANCE (OR A MINIMUM OF 2'-0") PAST THE OPENING <br />ON ALL SIDES. <br />16. PROVIDE ONE 95 FOR SINGLE LAYER, AND TWO #5 FOR DOUBLE LAYER REINFORCING, 4'-0" LONG, <br />DIAGONALLY AT EACH CORNER OF ALL WALL OPENINGS. <br />17.. REFERENCE TYPICAL DETAILS FOR THE DISPOSITION OF REINFORCEMENT AT WALL CORNERS, <br />WALL INTERSECTIONS, AND FOR BAPS IN SMALL WALL SECTIONS. <br />18. PROVIDE ##5 CARRIER BAR AT 3'-0" MAX SPACING FOR ALL WALL REINFORCING NOT SUPPORTED BY <br />OTHER TRANSVERSE REINFORCEMENT, <br />19. PROVIDE "CORNER" BAR AT CORNERS AND INTERSECTIONS FOR WALLS AND FOUNDATIONS EQUAL <br />IN SIZE, NUMBER AND SPACING TO HORIZONTAL REINFORCING. SIZE CORNER BAR TO PROVIDE A <br />FULL. LAP WITH HORIZONTAL REINFORCEMENT ON EACH LEG. <br />q.. i YaMI <br />4 I�� <br />�l b B h Ari <br />Otak Architects, Inc. <br />808 SW Third Avenue, Ste 800 <br />Portland, OR 97204 <br />503.?$7.682-5 <br />www.otak.corn <br />r10 T tJr�oj­!� <br />.. / <br />{ <br />FRO E LICH <br />EN(3IH EER5s <br />17700 SW Upper Boones Ferry Rd. <br />Suite #115 <br />Portland, Oregon 97224 <br />Office: (503) 624-7005 <br />Portland, OR. I Bend, OR. I Denver, CO. <br />froelich-engineers.coinjj FE# 19-T172 <br />CONSULTANT <br />Q <br />0 <br />CA <br />w <br />TITLE <br />REVISIONS <br />Author Checker <br />DRAWN BY CHECK BY <br />100% ISSUE SET/BID SET <br />STATUS <br />04/17/2020 <br />DATE <br />328801 <br />PROJECT NUMBER <br />