CONCRETE ACCESSORIES: <br />1. DEFORMED BAR ANCHORS (D.B.A.) SHALL BE NELSON TYPE D2L (ICC ESR-2907) OR APPROVED <br />EQUAL. <br />2. HEADED SHEAR STUDS SHALL BE NELSON HEADED ANCHORS WITH FLUXED ENDS (ICC ESR-2856) <br />OR APPROVED EQUAL. <br />3. HEADED SHEAR STUDS AND DEFORMED BAR ANCHORS SHALL BE AUTOMATICALLY END -WELDED <br />WITH THE MANUFACTURER'S STANDARD EQUIPMENT AND IN ACCORDANCE WITH THE ASSOCIATED <br />ICC REPORTS. <br />4. PERMANENTLY EXPOSED EMBEDDED PLATES AND ANGLES SHALL BE HOT -DIPPED GALVANIZED <br />,AFTER FABRICATION. EMBEDDED ITEMS SHALL NOT BE LOADED, NOR SHALL WELDS BE APPLIED, <br />FOR A MINIMUM OF 7-DAYS AFTER CASTING OF CONCRETE. <br />5. APPROVED POST -INSTALLED ANCHORS ARE AS FOLLOWS: <br />APPROVED POST -INSTALLED CONCRETE ANCHORS <br />TYPE <br />ANCHOR <br />ICC REPORT <br />SIMPSON TITEN HD <br />ICC ESR-2713 <br />CONCRETE <br />SCREW <br />DEWALT SCREW -BOLT+ <br />ICC ESR-3889 <br />HILTI KWIK HUS-EZ <br />ICC ESR-3027 <br />SIMPSON SET-3G <br />ICC ESR-4057 <br />EPDXY <br />ADHESIVE <br />DEWALT PURE110+ <br />ICC ESR-3298 <br />HILTI HIT -RE 500V3 <br />ICC ESR-3814 <br />SIMPSON AT-XP <br />IAPMO UES ER-263 <br />ACRYLIC <br />ADHESIVE <br />- <br />DEWALTAC200+ <br />_ <br />ICC ESR-4027 <br />HILTI HY 200 <br />ICC ESR-3187 <br />SIMPSON STRONG -BOLT II <br />ICC ESR-3037 <br />EXPANSION <br />DEWALT POWER STUD + SD2 <br />ICC ESR-2502 <br />HILTI KWIK BOLT-TZ <br />ICC ESR-1917 <br />NOTES: <br />A. ANCHOR LOCATIONS AND REQUIREMENTS SHALL CONFORM TO THOSE NOTED SPECIFICALLY <br />ON THE STRUCTURAL DRAWINGS. ALL OTHER LOCATIONS REQUIRE PRIOR APPROVAL. <br />B. ALL ANCHORS SHALL BE INSTALLED IN STRICT CONFORMANCE TO THE. APPLICABLE ICC <br />REPORT AND MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS. <br />C. REINFORCEMENT SHALL NOT BE CUT IN NEW, OR EXISTING CONCRETE DURING INSTALLATION <br />OF POST -INSTALLED ANCHORS. <br />D. ANCHORS THAT ARE LEFT EXPOSED TO WEATHER SHALL BE STAINLESS STEEL, OR HOT - <br />DIPPED GALVANIZED. <br />6. ADHESIVE ANCHORS SHALL BE INSTALLED ONLY IN DRY, HAMMER. -DRILLED DOLES. <br />7. INSTALLATION OF ADHESIVE ANCHORS SHALL BE PERFORMED ONLY BY ACl/CRSI CERTIFIED <br />ADHESIVE ANCHOR INSTALLERS. <br />8. ADHESIVE ANCHOR INSTALLATIONS IN HORIZONTAL, UPWARDLY INCLINED, AND OVERHEAD <br />ORIENTATIONS SHALL UTILIZE ADHESIVE MANUFACTURER'S PISTON PLUG AND TUBING DELIVERY <br />SYSTEM, PLACE ADHESIVE RETAINING CAP IN THE HOLE AFTER ADHESIVE INJECTION. <br />9. ADHESIVE ANCHOR INSTALLATIONS EXCEEDING 10" EMBEDMENT IN DOWNWARD INCLINED, AND <br />DOWNWARD ORIENTATIONS SHALL UTILIZE ADHESIVE MANUFACTURER'S PISTON PLUG AND TUBING <br />DELIVERY SYSTEM. <br />STRUCTURAL STEEL: <br />1. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING MINIMUM ASTM SPECIFICATIONS AND <br />GRADES: <br />STRUCTIJ L STEEL, <br />- <br />- --------------- <br />- <br />WIDE FLANGE SECTIONS <br />ASTM A-992, GRADE 50 (Fy=50 Kai) <br />PLATES WHERE NOTED <br />ASTM A572, GRADE 50 (Fy=50 KSI) <br />CHANNELS, ANGLES, PL ATES--EXCEPT AS NOTED <br />ASTM A-36 (Fy=36 KSI) <br />HOLLOW STRUCTURAL SECTIONS (TUBES) <br />A-500, GRADE B (Fy=46KS1) <br />PIPE <br />ASTM A53, TYPE E OR S (Fy=35 KSI) <br />2. DESIGN, FABRICATION, AND ERECTION SHALL BE IN ACCORDANCE WITH THE "RISC SPECIFICATION <br />FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL BUILDINGS" WITH <br />"COMMENTARY" AND THE "CODE OF STANDARD PRACTICE," WITH EXCEPTIONS AS NOTED IN THE <br />PROJECT SPECIFICATIONS. <br />3. REFERENCE PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS FOR MEMBERS PART OF <br />THE SEISMIC LOAD RESISTING SYSTEM (SLRS). <br />4. BOLTS SHALL CONFORM TO THE ASTM AND RCSC SPECIFICATIONS FOR JOINTS USING A325 OR <br />A490 HIGH STRENGTH BOLTS, BOLTS SHALL BE SNUG TIGHT UNLESS NOTED OTHERWISE. <br />5. WELDING SHALL CONFORM TO THE AWS CODES FOR ARC AND GAS WELDING IN BUILDING <br />CONSTRUCTION. WELDING SHALL BE PERFORMED IN ACCORDANCE WITH A WELDED PROCEDURE <br />SPECIFICATION (WPS) AS REQUIRED IN AWS 01.1 AND APPROVED BY THE STRUCTURAL ENGINEER <br />OF RECORD. THE WPS VARIABLES SHALL BE WITHIN THE PARAMETERS ESTABLISHED BY THE <br />FILLER -METAL MANUFACTURER. <br />6. FOR MEMBERS INCLUDED IN THE SEISMIC LOAD RESISTING SYSTEM (SLRS), REQUIREMENTS OF <br />AWS D1.8 (SEISMIC SUPPLEMENT) SHALL APPLY. <br />7. ALL WELDS USED IN THE SEISMIC LOAD RESISTING SYSTEM (SLRS), SHALL BE MADE WITH A FILLER <br />METAL THAT HAS A CHARPY V-NOTCH (CVN) TOUGHNESS OF 20 FT-LBS AT 0 DEGREES FAHRENHEIT <br />(F), AS DETERMINED BY AWS CLASSIFICATION OR MANUFACTURER CERTIFICATION, ALL COMPLETE <br />JOINT PENETRATION WELDS DESIGNATED AS "DEMAND CRITICAL" SHALL BE MADE WITH FILLER <br />METAL THAT HAS A CVN TOUGHNESS OF 20 FT-LBS AT MINUS 20 DEGREES F, AND 40 FT-LBS AT 70 <br />DEGREES F. <br />8. FOR COMPLETE JOINT PENETRATION WELDS ASSOCIATED WITH MEMBER SPLICES AND <br />CONNECTIONS NOT PART OF THE SLRS, WELDS SHALL BE MADE WITH FILLER METAL THAT HAS A <br />MINIMUM CVN TOUGHNESS OF 20 FT-LBS AT 40 DEGREES F. <br />9. FOR MEMBERS AND CONNECTIONS THAT ARE PART OF THE SEISMIC LOAD RESISTING SYSTEM, <br />DISCONTINUITIES CREATED BY ERRORS, OR BY FABRICATION OR ERECTION OPERATIONS, SUCH <br />AS TACK WELDS, ERECTION AIDS, AIR -ARC GOUGING, OR FLAME CUTTING, SHALL BE REPAIRED AS <br />REQUIRED BY THE STRUCTURAL ENGINEER. <br />10. WELDS SHALL BE MADE USING E70XX ELECTRODES AND SHALL BE 3/16" MINIMUM, UNLESS NOTED <br />OTHERWISE ON THE DRAWINGS. <br />11. WELDING SHALL BE MADE BY AWS CERTIFIED WELDERS. <br />12. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE BETWEEN THE ARCHITECTURAL: <br />ELECTRICAL AND STRUCTURAL DRAWINGS TO PRODUCE THE SHOP DRAWINGS. <br />13. ALL STEEL EXPOSED TO WEATHER, MOISTURE, SOIL, OR AS NOTED ON PLANS SHALL BE HOT <br />GALVANIZED IN ACCORDANCE WITH ASTM A-123, OR HAVE AN APPROVED PROTECTIVE COATING. <br />14. PROVIDE NON -SHRINK GROUT UNDER ALL BASE PLATES. GROUT SHALL BE FACTORY -PACKAGED, <br />8000 PSI MINIMUM AT 28 DAYS AND SHALL COMPLY WITH ASTM C 1107, <br />15. PROVIDE WEEP HOLES AT ALL EXTERIOR CLOSED SECTIONS WHERE MOISTURE MAY <br />ACCUMULATE. <br />F16. -0) FAESS STEEL IN UNHEATED OR EXTERNAL SPACES, SKIP OR STITCH WELDS ARE NOT <br />PERMITTED, ALL STEEL JOINTS SHALL BE FULLY WELDED AND GROUND SMOOTH. WHERE SKIP OR <br />STITCH WELDS HAVE BEEN INDICATED ON THE DRAWINGS, PROVIDE CONTINUOUS WELDS OR <br />PROVIDE SEAL WELD BETWEEN SKIP WELDS TO CLOSE ANY GAPS. ALL WELDED SURFACES <br />EXPOSED TO WEATHER SHALL BE SEALED COMPLETELY WITH WELDS TO PREVENT WATER <br />EXPOSURE BETWEEN JOINED SURFACES. <br />17. STEEL FABRICATION SHALL BE PERFORMED BY AN RISC -CERTIFIED STEEL FABRICATOR. IF THE <br />FABRICATOR IS NOT AISC CERTIFIED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING <br />A SPECIAL INSPECTOR TO INSPECT THE STEEL FABRICATION AT NO COST TO THE OWNER. <br />STEEL DECKING: <br />1. STEEL DECK SHALL CONFORM TO ASTM A653 DESIGNATION SS, GRADE 33 MINIMUM WITH 38KS1 <br />MINIMUM YIELD STRENGTH. <br />2 STEEL FLOOR DECK SHALL BE A COMPOSITE TYPE W, OF THE SIZE AND GAUGE SHOWN ON THE <br />STRUCTURAL DRAWINGS. <br />3. STEEL ROOF DECK SHALL BE 3" TYPE PLN OF THE GAUGE SHOWN ON THE STRUCTURAL <br />DRAWINGS. <br />4. THE GALVANIZED COATING SHALL CONFORM TO ASTM A653, G60 (G90 WHERE LEFT PERMANENTLY <br />EXPOSED TO WEATHER. <br />5. MINIMUM DECK GAUGES ARE SHOWN ON THE PLANS AND ARE BASED ON 3-SPAN, UN -SHORED <br />CONDITIONS. FOR OTHER SPAN CONDITIONS, DECK MANUFACTURER SHALL EVALUATE SHORING <br />REQUIREMENTS. <br />6. MINIMUM DECK PROPERTIES SHALL BE AS FOLLOWS: <br />FLOOR DECK <br />DECK SIZE --- 1, (IN-4/FT) <br />S, (IN 113/FT) <br />2" 18 GAUGE 0.564 <br />0.471 <br />ROOFDECK <br />DECK SIZE 1, (IN" 4/FT) S, (IN" 3/FT) <br />3" 16 GAUGE 1.571 0.883 <br />7. FLOOR AND ROOF DECK WELDING SHALL BE AS FOLLOWS: <br />AT TRANSVERSE <br />AND PERIMETER AT LONGITUDINAL SUPPORTS AT SIDE LAP CONNECTIONS <br />SUPPORTS <br />1/2" EFFECTIVE BUTTON PUNCH OR 1/2" TOP <br />DIAMETER PUDDLE 1/2" EFFECTIVE DIAMETER PUDDLE WELDS @ OR SIDE SEAM WELD @ 36" <br />WELDS @ 12" OC 16" OC OC <br />8. ROOF DECK SHALL BE ATTACHED AS SPECIFIED WITHIN THE STRUCTURAL DRAWINGS. <br />9. DO NOT HANG OR SUSPEND STRUCTURAL ITEMS DIRECTLY FROM THE ROOF DECK. NON- <br />STRUCTURAL ITEMS SUSPENDED FROM THE DECK SHALL BE REVIEWED AND APPROVED BY THE <br />ARCHITECT AND STRUCTURAL ENGINEER PRIOR TO INSTALLATION. <br />10. AT ENT BEARING SUPPORTS, DECK TO FULLY BEAR ON SUPPORTING MEMBERS 2" MINIMUM <br />TYPICAL AT ROOF AND FLOOR DECK. <br />11. AT FLOOR DECK END SPLICES, BUTT DECK ENDS TIGHTLY TOGETHER OVER FRAIVIING MEMBER <br />AND ATTACH DECK TO FRAMING MEMBERS, REF PLAN. <br />12. AT ROOF DECK END SPLICES, LAP DECK 2" MINIMUM OVER FRAMING MEMBER AND ATTACH DECK <br />TO FRAMING MEMBERS, REF PLAN. <br />13. MONITOR AND ADJUST DECK WIDTH MODULES (+/- 1/2") TO MAINTAIN PARALLEL LINES AND LAYOUT <br />AND TO ENSURE DECK VALLEYS ALIGN WITH ALL PARALLEL SUPPORTS AND COLLECTORS. DO NOT <br />RIP DECK SHEETS LENGTHWISE AND BEND DOWN TO FASTEN THE HIGH FLUTE TO PARALLEL <br />SUPPORTS. <br />LIGHT GAGE STEEL FRAMING: <br />1. METAL STUDS SHALL BE C-STUDS WITH A MINIMUM YIELD STRENGTH OF 33 KSI FOR 33 AND 43 MILS <br />AND 50 KSI FOR 54, 68, AND 97 MILS. <br />2. STUDS SHALL BE OF SAME SIZE, GAUGE AND SPACING AS SHOWN ON THE STRUCTURAL <br />DRAWINGS. <br />3. PROVIDE BRIDGING IN CONFORMANCE WITH THE STEEL STUD MANUFACTURERS ASSOCIATION'S <br />(SSMA) RECOMMENDATIONS ADEQUATE FOR DEVELOPMENT OF THE FULL MOMENT CAPACITY. <br />4. ALL TRACKS SHALL BE OVERSIZED TO PROVIDE FULL STUD END BEARING. <br />5. SCREWS SHALL BE ELCO DRIL-FLEX, OR HILTI KWIK-FLEX (ICC ER-4760). SCREWS SHALL EXTEND <br />THROUGH ALL MEMBERS WITH A MINIMUM OF 3 EXPOSED THREADS. <br />6. WELDING SHALL CONFORM WITH AWS D1.3 AND BE COMPLETED BY AWS WELDERS CERTIFIED FOR <br />LIGHT GAGE STEEL, <br />7. LOW VELOCITY FASTENERS SHALL BE 0.157" DIAMETER HILTI X-U (ICC ESR-2269). <br />C,. WHERE STUD CLIPS ARE ATTACHED SLAB EDGE ANGLES, SCREWS AND PATS SHALL BE INSTALLED <br />PRIOR TO CONCRETE SLAB PLACEMENT. AFTER SLAB IS PLACED, WELDS SHALL BE USED <br />CONTACT FROELICH ENGINEERS FOR WELD SIZES. <br />9. PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT LIMITED TO BRIDGING, TRACKS, CLIPS, WEB <br />STIFFENERS, ANCHORS, FASTENING DEVICES AND OTHER ACCESSORIES REQUIRED FOR A <br />COMPLETE AND PROPER INSTALLATION. <br />10. SPLICES IN STUDS ARE NOT PERMITTED. <br />11. STUDS SHALL BE SCREWED TO THE FLANGES OF BOTH UPPER AND LOWER TRACKS. <br />12. JOIST SHALL BE BRACED WITH BRIDGING„ REF MANUFACTURER'S SPECIFICATIONS. <br />SATIN FRAMING LUMBER: <br />1. SAWN LUMBER SHALL CONFORM TO THE WEST COAST LUMBER INSPECTION BUREAU <br />(WCLIB) OR THE WESTERN WOODS PRODUCTS ASSOCIATION (WWPA) GRADING RULES. <br />2. ALL LUMBER SHALL BE THE SPECIES AND GRADES AS FOLLOWS: <br />SAWN LUMBER <br />- USE <br />SPECIES/GRADE 1 <br />FIB PSI) --BASE VALUE <br />LUMBER 2" TO 4" THICK <br />DOUGLAS FIR -LARCH <br />900 <br />N O.2 <br />BEAMS 5"x5" AND GREATER <br />DOUGLAS FIR -LARCH <br />--- 1350 --- <br />NO.1 <br />POSTS <br />D FIR -LARCH <br />DOUGLAS <br />1200 <br />NOA <br />T AND G DECKING <br />DOUGLAS <br />DOUGLAS FIR LARCH <br />COMMERCIAL DEX <br />MOISTURE3, ALL DIMENSIONAL LUMBER AND TIMBERS SHALL BE KILN DRIED AND CERTIFIED IN WRITING <br />BY THE SUPPLIER TO BE LESS THAN 19 PERCENT <br />4, ALL LUMBER IN CONTACT WITH CONCRETE PRESERVATIVE <br />,rACCORDANCE-- -. AMERICAN WOOD PRESERVERS BUREAU a S- <br />QUALITY MARK. <br />5. CUTTING AND NOTCHING OF JOISTS AND STUDS SHALL CONFORM TO IBC SECTIONS <br />AN APPROVED MOISTURE BARRIER IS PROVIDED. ALL PT LUMBER SHALL BEAR THE AWPB <br />6. PROVIDE - LINES OF BLOCKING, SAME DEPTH OF FRAMINGB N AT ALL <br />BEARING <br />WOOD STRUCTURAL PANEL SHEATHING: <br />1 . WOOD STRUCTURAL ROOF AND FLOOR PANELS SHALL CONFORMTO THE REQUIREMENTS <br />PRODUCT STANDARD PS I FOR <br />CONSTRUCTION INDUSTRIAL r-._. <br />THE "U.S. PRODUCT STANDARD PS 2 PERFORMANCE STANDARD WOOD -BASED <br />STRUCTURAL USE PANELS," Or s3 PERFORMANCE STANDARDS." <br />2. UNLESS NOTED OTHERWISE ON THE DRAWINGS, ALL PANELS SHALL BE APA RATED <br />SHEATHING, EXPOSURE 1, OF THE THICKNESS AND SPAN RATING AS FOLLOWS: <br />MOOD STRUCTURAL PANEL BREATHING <br />USE THICKNESS/RATING <br />ROOF SHEATHING I 15/32"-INDEX 32/16 <br />FLOOR SHEATHING (SECTOR 1) 15/32"-INDEX 32/16 <br />FLOOR SHEATHING (SECTOR 11) 1 1/8"-INDEX 60132 <br />3. ALL FLOOR AND ROOF SHEATHING SHALL BE INSTALLED FACE GRAIN <br />PERPENDICULAR TO SUPPORTS AND <br />_ND JOINTS SHALL-; r - <br />4, ROOF SHEATHING SHALL BE BLOCKED WHERE INDICATED, OR HAVE EDGES SUPPORTED <br />BY D. <br />5, FLOOR SHEATHING PANELS SHALL BE FIELD GLUED TO THE FRAMING <br />MEETING THE APA SPECIFICATION TONGUE D -O; <br />SHALL ALSO BE GLUED AT THE T AND G JOINT, I <br />NAILING AND FASTENERS: <br />1. ALL FRAMING NAILS SHALL BE OF THE SIZE AND NUMBER INDICATED ON THE DRAWINGS <br />AND CONFORM TO THE "STANDARD SPECIFICATION OF DRIVEN FASTENERS: NAILS, <br />SPIKES, AND STAPLES" (ASTM F1667) AND "POWER -DRIVEN STAPLES AND NAILS FOR USE IN <br />ALL TYPES OF BUILDING CONSTRUCTION" (NER 272). <br />2. NAILING NOT SHOWN SHALL BE AS INDICATED ON IBC TABLE 2304.9.1, OR NER-272. <br />3. NAILS SHALL BE IDENTIFIED BY LABELS ATTACHED TO THEIR CONTAINERS, THAT SHOW <br />THE MANUFACTURER'S NAME, NAIL SHANK DIAMETER, AND LENGTH. <br />4. NAIL SIZES SHALL BE AS FOLLOWS: <br />FRAMING NAILS <br />NAIL TYPE <br />SHANK DIAMETER (IN) <br />MINIMUM PENETRATION <br />INTO FRAMING MEMBER (IN) <br />6d <br />0.113 <br />1.250 <br />8d <br />0.131 <br />1.375 <br />10d <br />0.148 <br />1.500 <br />16d <br />0.162 <br />1.625 <br />5. UNLESS OTHERWISE NOTED ON PLANS, PLYWOOD SHEATHING SHALL BE ATTACHED TO <br />TIME FRAMING SUPPORTS AS FOLLOWS: <br />SHEATHING NAILING <br />USE <br />PANEL EDGES <br />INTERMEDIATE FRAMING <br />MEMBERS <br />ROOF SHEATHING <br />0.131°" DIA AT 6" OC <br />0.131" DIA AT 12" OC <br />FLOOR SHEATHING <br />0.148" DIA AT 6" OC <br />0.148" DIA AT 12" OC <br />WALL SHEATHING <br />0.131" DIA AT 6" OC <br />0.131" DIA AT 12" OC <br />NOTES. - <br />A. ALL NAILS SHALL BE COMMON NAILS EXCEPT DING SHANKS SHALL BE USED FOR <br />FASTENING ROOF SHEATHING. <br />6. BOLTS AND LAG SCREWS SHALL CONFORM TO ANSUASME STANDARD 818.2.1-1981. ALL <br />BOLTS AND LAG SCREWS SHALL BE INSTALLED WITH STANDARD CUT WASHERS. ALL A307 <br />BOLTS SHALL HAVE CUT THREADS. <br />7. PRE -DRILL HOLES FOR LAG BOLTS. SOAP THREADS OF LAGS IMMEDIATELY PRIOR TO <br />INSTALLATION. <br />8. JOIST HANGERS, HOLDOWNS, AND OTHER FRAMING ACCESSORIES SHALL BE <br />MANUFACTURED BY SIMPSON STRONG TIE (OR AN APPROVED EQUAL) AND BE OF THE SIZE <br />AND TYPE SHOWN ON THE DRAWINGS. HARDWARE FASTENERS SHALL BE INSTALLED IN <br />STRICT CONFORMANCE TO THE MANUFACTURER'S REQUIREMENTS. ANY PRODUCT <br />SUBSTITUTIONS TO SIMPSON SHALL MEET OR EXCEED SIMPSON'S PUBLISHED DESIGN <br />CAPACITIES AND MUST HAVE A CURRENT ICC EVALUATION REPORT FOR THE APPLICABLE <br />CODES. <br />9. HANGERS NOT SHOWN SHALL BE SIMPSON U-TYPE, OR B-TYPE OF THE SIZE <br />RECOMMENDED FOR THE SPECIFIC FRAMING MEMBER SHOWN ON PLAN. <br />10. FASTENERS (NAILS, BOLTS, SCREWS, LAG SCREWS, ETC) IN CONTACT WITH PT LUMBER <br />AND SHEATHING SHALL BE HOT DIPPED ZINC -COATED GALVANIZED STEEL, OTHER <br />FASTENERS AND HARDWARE IN CONTACT WITH PT LUMBER AND SHEATHING SHALL BE OF <br />MECHANICALLY DEPOSITED ZINC -COATED STEEL WITH COATING WEIGHTS IN <br />ACCORDANCE WITH ASTM B695, CLASS 55 MINIMUM. CONNECTORS 1N CONTACT WITH <br />EXTERIOR APPLICATIONS OF PT LUMBER AND SHEATHING SHALL HAVE BE ZINC -COATED <br />GALVANIZED STEEL IN ACCORDANCE WITH ASTMA653, TYPE G185. ADDITIONALLY, <br />FASTENER TYPE AND COATINGS SHALL COMPLY WITH THE WRITTEN REQUIREMENTS OF <br />THE MANUFACTURER. NO SUBSTITUTIONS PERMITTED. <br />11. FASTENERS (NAILS, BOLTS, SCREWS, LAG SCREWS, ETC) IN CONTACT WITH FRT LUMBER <br />AND SHEATHING SHALL BE HOT DIPPED ZINC -COATED GALVANIZED STEEL. OTHER <br />FASTENERS AND HARDWARE IN CONTACT WITH FRT LUMBER AND SHEATHING SHALL BE <br />OF MECHANICALLY DEPOSITED ZINC -COATED STEEL WITH COATING WEIGHTS IN <br />ACCORDANCE WITH ASTM B695, CLASS 55 MINIMUM. ADDITIONALLY, FASTENER TYPE AND <br />COATINGS SHALL COMPLY WITH THE WRITTEN REQUIREMENTS OF THE MANUFACTURER. <br />12. SILLS AT WALLS SHALL BE BOLTED TO CONCRETE WITH 5/8" DIAMETER x 7" EMBED <br />ANCHOR BOLTS AT 4'-0" OC MAXIMUM AND WITHIN V-0" OF SILL PLATE ENDS, CORNERS OR <br />SPLICES, UNLESS DETAILED OTHERWISE. WASHERS TO BE MINIMUM 1/4"x3"x3", IN <br />ACCORDANCE WITH IBC 2305.111. <br />13, ALL SILL PLATES AND LEDGERS SHALL DE ANCHORED WITH A MINIMUM OF THREE <br />FASTENERS PER PIECE;. <br />GLUED LAMINATED MEMBERS: <br />1. GLUED LAMINATED MEMBERS SHALL BE FABRICATED IN CONFORMANCE WITH THE <br />"AMERICAN NATIONAL STANDARD FOR STRUCTURAL GLUED LAMINATED TIMBER" <br />(ANSI/AITC A190.1), OR OTHER CODE -APPROVED DESIGN, MANUFACTURING AND QUALITY <br />ASSURANCE PROCEDURES. <br />2. ADHESIVE SHALL BE WET -USE EXTERIOR WATERPROOF GLUE. <br />3, EACH MEMBER SHALL BEAR AN AITC OR APA-EWS IDENTIFICATION MARK OR BE <br />ACCOMPANIED BY A CERTIFICATE OF CONFORMANCE. <br />4. ONE COAT OF END SEALER SHALL BE APPLIED IMMEDIATELY AFTER TRIMMING IN EITHER <br />THE SHOP OR FIELD. <br />5. NOTCHING AND/OR BORING OF GLUED LAMINATED MEMBERS (EITHER IN THE SHOP, OR <br />FIELD) IS STRICTLY PROHIBITED UNLESS AS SPECIFICALLY DETAILED IN THE STRUCTURAL <br />DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER OF RECORD. <br />6. GLUED LAMINATED TIMBER BEAMS SHALL BE WESTERN SPECIES WITH THE FOLLOWING <br />STRENGTH PROPERTIES, UNLESS OTHERWISE NOTED ON PLANS: <br />GLUED LAMINATED MEMBERS <br />COMBINATION <br />MODULUS OF <br />FLEXURAL <br />HORIZONTAL SHEAR <br />SYMBOL <br />USE � <br />ELASTICITY <br />STRESS <br />STRESS (PSI) <br />(SPECIES) <br />(PSI) <br />(PSI) <br />24F-V4 (DF/DF) <br />- <br />SIMPLE SPAN <br />-- <br />1,800,000 <br />2,400 <br />265 <br />L®E VERED <br />CANTILEVERED <br />24F-V8 (DF/DF) <br />OR <br />1,800,000 <br />2,400 <br />265 <br />CONTINUOUS <br />7. GLULAM MEMBERS SHALL BE OF THE FOLLOWING APPEARANCE GRADE(S), UNLESS <br />OTHERWISE NOTED ON PLANS: ARCHITECTURAL <br />ENGINEERED COMPOSITE LUMBER: <br />1. ENGINEERED COMPOSITE WOOD PRODUCTS SUCH AS LAMINATED VENEER LUMBER <br />(MICROLAM), PARALLEL STRAND LUMBER (PARALAM), AND LAMINATED STRAND LUMBER <br />(TIMBERSTRAND) SHALL BE OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS, <br />MANUFACTURED BY TRUS-JOIST OR AN APPROVED EQUAL, <br />2. MEMBERS SHALL HAVE THE FOLLOWING MINIMUM DESIGN PROPERTIES: <br />ENGINEERED COMPOSITE LUMBER <br />COMPOSITE LUMBER TYPE MODULUS OF ELASTICITY <br />ALLOWABLE FLEXURAL <br />(PSI) <br />STRESS (PSI) <br />LSL <br />- <br />1,500,000 <br />2,350 <br />LVL <br />1,900,000 <br />2,600 <br />PSL <br />2,000,000 <br />2,900 <br />NOTE: FLEXURAL STRESSES NOTED ABOVE. ARE FOR 12" DEEP MEMBERS, DEEPER <br />MEMBERS SHALL BE DESIGNED FOR REDUCED STRESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S REQUIREMENTS. <br />T <br />Otak Architects, Inc. <br />808 SW Third Avenue, Ste 800 <br />Portland, OR 97204 <br />503.287.6825 <br />www.otak.com <br />ad UCTU <br />eMZzij <br />, <br />LI CH <br />17700 SW Upper Boones Ferry Rd. <br />Suite #115 <br />Portland, Oregon 97224 <br />Office: (503) 624-7005 <br />Portland, OR. I Bend, OR, I Denver, CO. <br />troelich-engineers.corn I FE9 19-T172 <br />CONSULTANT <br />0 <br />TITLE <br /># DATE DESCRIPTION <br />A 4/17/2020 PLAN REVISIONS <br />REVISIONS <br />Author Checker <br />DRAWN BY CHECK BY <br />100% ISSUE SET/BID SET <br />STATUS <br />04/17/2020 <br />DATE <br />328801 <br />PROJECT NUMBER <br />0 2020 OTAK, INC. <br />If this drawing is not 24 "x 36", it has been <br />reducedlenlarged. Scale accordingly. <br />