Laserfiche WebLink
6 BUILDING HEIGHT AND AREA, C NT°D <br />K,< <br />1 <br />in <br />al <br />L� xs <br />nt}1 <br />zt <br />00 <br />CN <br />O <br />r-, <br />Q <br />PLUMBING FITUIE CALCULATIONS <br />OCCUPANT LOAD FOR PLUMBING <br />FIXTURES <br />LEVEL 01 <br />A-3 - ROOMS 009, 010 <br />126 <br />ROOMS 080, 081, 082 <br />172 <br />TOTAL <br />298 ( 2 = 149 M + 149 F <br />B - ALL OTHER SPACES <br />442 f 2 = 221 M +221 F <br />LEVEL 02 <br />B - ALL ROOMS <br />45012 = 225 M 225 F <br />FIXTURE CALCULATIONS <br />i WATERCLOSETS <br />LAVATORIES <br />MALE <br />FEMALE <br />j MALE <br />i FEMALE <br />LEVEL 01 - A-3 <br />j 1491125 =1.19 <br />149 / 65 = 2.29 <br />149 l 200 <br />= 0.75 <br />G 149 / 200 = 0.75 <br />LEVEL 01 - B <br />50 f 25 = 2.0 <br />50 125 = 2.0 <br />80 / 40 <br />= ZO <br />80/40 = 2.0 <br />_ <br />I ' 171 / 50 3.42 <br />- 2 <br />171 J 0 - .4_ <br />5 3 <br />141 80 <br />/ <br />- <br />-1.76 <br />41 -1 <br />1 / 80 .76 <br />LEVEL 01 REQUIRED <br />i 6.61 <br />7.71 <br />4.51 <br />4.51 <br />j <br />LEVEL 02 - B <br />50 / 25 = 2.0 <br />50 / 25 = 2.0 <br />80 / 40 <br />= 2.0 <br />80140 = 2.0 j <br />175/50 =3.5 <br />175/50=3.5 <br />1 145/80 <br />=1.81 <br />145/80=1.81 <br />LEVEL 02 REQUIRED <br />5.5 <br />5.5 <br />3.81 <br />3.81 <br />DRINKING FOUNTAINS OCC LOAD REQUIRED <br />FIRST 150 OCCUPANTS 150 1 <br />EACH ADDITIONAL 500 1040 3 <br />TOTAL 1190 4 <br />ACCESSIBLE MEANS OF EGRESS MAXIMUI AREA OF EXTERIOR WALL OPENINGS <br />1009,4 ELEVATORS 70aB WAIT OPENINGS <br />ELEVATORS SHALL COMPLY WITH THE EMERGENCY OPERATION AND SIGNALING DEVICE FIRE SEPARATION DISTANCE 30'-0" OR GREATER - UNLIMITED OPENINGS <br />REQUIREMENTS OF SECTION 2.27 OF ASME Al7.1/CSA B44. STANDBY POWER SHALL BE <br />BUILDING PROVIDED PER CHAPTER 27 AND SECTION 3003.. G SEPARATION REQUIREMENTS <br />DISTANCE TO CENTERLINE OF STREET EXCEEDS 30' ON NORTH, SOUTH, EAST, AND WEST <br />SIDES AS NOTED. THEREFORE NO FIRE RESISTIVE RATING REQUIRED. SEE SITE PLAN G4.01 <br />EXIT ACCESS TRAVEL DISTANCE <br />COMMON PATIO OF TRAVEL DISTANCE <br />REFER TO FLS PLANS ON SHEETS G2,01 AND GZ02 <br />11 ACCESSIBILITY <br />ACCESSIBLE ROUTE <br />REFER TO SHEET G3.01 FOR TYPICAL ACCESSIBLE DESIGN CLEARANCES, MOUNTING HEIGHTS, <br />REACH RANGES, AND HANDRAILS. <br />1101.2.1 CLEAR WIDTH OF ACCESSIBLE ROUTE <br />FOR EXTERIOR ROUTES OF TRAVEL, THE MINIMUM CLEAR WIDTH SHALL BE 44 INCHES. <br />1104A SITE ARRIVAL POINTS <br />ACCESSIBLE ROUTE PROVIDED FROM PUBLIC WAY AT W. CASINO ROAD MAIN ENTRY. SEE SITE <br />PLAN SHEET G4.01. <br />PARKING <br />PLUMBING FIXTURES PROVIDES <br />WATERCLOSETS t URINALS <br />LAVATORIES <br />SHOWERS SEE PARKING SUMMARY THIS SHEET AND SITE STATS ON SHEET C2.01, <br />MALE <br />FEMALE <br />UNISEX <br />MALE FEMALE <br />UNISEX <br />MALE i FEMALE j <br />LEVEL 01 <br />4 ,- 3 <br />7 <br />2 <br />6 6 <br />2 <br />2 1 2 <br />LEVEL 02 <br />4 +3 <br />7 <br />- <br />6 6 <br />v <br />131 ENERGY EFFICIENCY <br />TOTALS <br />14 <br />14 <br />2 <br />12 12 <br />2 <br />2 2 <br />DRINKING FOUNTAINS <br />WATER COOLERS BOTTLE FILLERS <br />LEVEL 01 1 1 <br />LEVEL 02 1 1 <br />TOTALS j 2 2 <br />mmNadjawl = r I 1• <br />HOISTWAY ENCLOSURES <br />3002.1 HOISTWAY ENCLOSURE PROTECTION <br />ELEVATOR HOISTWAY ENCLOSURES TO BE SHAFT ENCLOSURES COMPLYING WITH <br />SECTION 713, <br />EMERGENCY OPERATIONS <br />3003.1 STANDBY POWER <br />TWO ELEVATORS TO BE CONNECTED TO STANDBY EMERGENCY GENERATOR POWER AND <br />OPERATED PER SECTION 3003,1.3. <br />€ { " <br />CHAPTER PROVISIONS FOR ALL COMPLIANCE METHODS <br />301.1.2 WORK AREA COMPLIANCE METHOD <br />ALTERATIONS. AND ADDITIONS TO THE EXISTING BUILDING SHALL COMPLY WITH APPLICABLE <br />REQUIREMENTS OF CHAPTERS 5 THROUGH 13 OF THIS CODE. <br />CHAPTER 1 CLASSIFICATION OF WORK <br />505,1 SCOPE <br />LEVEL 3 ALTERATIONS APPLY WHERE THE WORK AREA EXCEEDS 50 PERCENT OF THE BUILDING <br />AREA.. <br />505.2 APPLICATION <br />LEVEL 3 ALTERATIONS SHALL COMPLY WITH THE PROVISIONS OF CHAPTERS 7 AND 8 FOR LEVEL 1 <br />AND 2 ALTERATIONS AS WELL AS THE PROVISIONS OF CHAPTER 9. <br />507.2 APPLICATION <br />ADDITIONS TO EXISTING BUILDINGS SHALL COMPLY WITH PROVISIONS OF CHAPTER 11. <br />CHAPTER 9 1 ALTERATIONS - LEVEL <br />901.2 COMPLIANCE <br />IN ADDITION TO CHAPTER 9 PROVISIONS, WORK SHALL COMPLY WITH ALL REQUIREMENTS OF <br />CHAPTERS 7 AND 8. <br />SEE REFERENCED SECTIONS OF 2015 IBC AND OTHER LISTED CODES FOR APPLICABLE CODE <br />SECTIONS UTILIZED FOR DESIGN. <br />CHAPTER 111 ADDITIONS <br />SEE REFERENCED SECTIONS OF IBC FOR APPLICABLE CODE SECTIONS UTILIZED FOR DESIGN <br />OF THE ADDTIONS. <br />SCOPE / CRITERIA <br />REFER TO MECHANICAL DRAWINGS AND ENVELOPE COMPONENT CALCULATIONS FOR <br />COMPLIANCE PER 2015 WSEC, <br />THERMAL RATINGS OF DOORS AND FENESTRATION TO COMPLY WITH 2O15 WSEC <br />SECTIONS C402.1 AND C402.2 FOR CLIMATE ZONE 5 AND MARINE 4. <br />TABLE C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS <br />OPAQUE DOORS (SWINGING) MAXIMUM U-FACTOR = U-0.37 <br />TABLE C402.4 BUILDING ENVELOPE FENESTRATION <br />VERTICAL FENESTRATION MAXIMUM U-FACTOR <br />METAL FRAMING (FIXED) .38 <br />METAL FRAMING (ENTRANCE DOORS) .60 <br />SHGC SEW N <br />PF < 0.2 0A0 0.53 <br />0.2 <_ PF < 0.5 OA8 0.58 <br />PF>_0.5 0.64 0.64 <br />SKYLIGHTS <br />U-FACTOR 0.50 <br />SHGC 0.35 A <br />FIRE CLASSIFICATION <br />TABLE 1505.1 MINIMUM ROOF COVERING CLASSIFICATION <br />CONSTRUCTION TYPE III-B: ROOF ASSEMBLIES TO BE CLASS C OR HIGHER (NEW AND EXISTING). <br />MECHANICAL EQUIPMENT SCREENS <br />1510.6 MECHANICAL EQUIPMENT SCREENS <br />HEIGHT LIMITED TO 18' ABOVE ROOF DECK: <br />RISK CATEGORY <br />TABLE 1604,5: STRUCTURAL DESIGN FOR RISK CATEGORY IV, LIFE SAFETY CRITERIA. <br />REFERENCE STRUCTURAL DRAWINGS AND CALCULATIONS. <br />SAFETY GLAZING <br />2406.4 HAZARDOUS LOCATIONS <br />THE LOCATIONS SPECIFIED IN SECTIONS 206A.1 THROUGH 2406.4.7 SHALL BE CONSIDERED <br />SPECIFIC HAZARDOUS LOCATIONS REQUIRING SAFETY GLAZING MATERIALS. <br />GLASS IN HANDRAILS AND GUARDS <br />2407.1 MATERIALS <br />GLASS USED IN A HANDRAIL, GUARDRAIL, OR GUARD SECTIONS SHALL BE LAMINATED GLASS <br />CONSTRUCTED OF FULLY TEMPERED OR HEAT -STRENGTHENED GLASS, <br />GUARDS WITH STRUCTURAL GLASS PANELS SHALL BE INSTALLED WITH ATTACHED TOP RAIL OR <br />HANDRAIL SUPPORTED BY A MINIMUM OF THREE GLASS BALUSTER PANELS. <br />. � r <br />MINIMUM PLUMBING FACILITIES <br />TABLE 2902,1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES <br />WATERCLOSETS LAVATORIES <br />OCCUPANCY I MALE FEMALE MALE FEMALE <br />A-3 1 PER 125 1 PER 65 1 PER 200 <br />S 1 PER 25 FOR FIRST 50/ 1 1 PER 40 FOR FIRST 801 <br />1 PER 50 FOR REMAINDER 1 PER 80 FOR REMAINDER <br />2902.5.1 DRINKING FOUNTAIN NUMBER <br />OCCUPANT LOADS OVER 30 - 1 PER FIRST 150 1 PER EACH ADDITIONAL 500 <br />2902,5.4.2 BOTTLE FILLING STATIONS - SUBSTITUTION <br />BOTTLE FILLING STATIONS PERMITTED TO BE SUBSTITUTED FOR UP TO 50 PERCENT OF <br />REQUIRED NUMBER IN OCCUPANCIES REQUIRING MORE THAN TWO DRINKING FOUNTAINS PER <br />FLOOR. <br />FACADE PROTECTION I SPRINKLERING DISTANCE TO CENTERLINE OF <br />STREET OR PROPERTY LINE <br />NORTH UP/Sp 172' 0" <br />EAST UP/Sp 164' 6" <br />SOUTH UP I SP 65'- 0" <br />WEST UP/Sp 165' - 0" <br />FIRE RATED BARRIERS <br />FIRE -RESISTANCE RATING REQUIRED PROVIDED <br />TYPICAL SHAFT WALLS 1 HR FIRE BARRIER (713,4) 1 HR FIRE BARRIER <br />ELEVATOR HOISTWAY 1 HR FIRE BARRIER (713.14) 1 HR FIRE BARRIER <br />INTERIOR EXIT STAIRWAYS 1 HR FIRE BARRIER (1023,2) 1 HR FIRE BARRIER <br />ELEVATOR MACHINE ROOM 1 HR FIRE BARRIER (3005.4) 1 HR FIRE BARRIER <br />TABLE 803.11 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY (SPRINKLERED) <br />INTERIOR EXIT CORRIDORS & ENCLOSURE <br />STAIRWAYS & RAMPS & FOR EXIT ACCESS ROOMS & <br />EXIT PASSAGEWAYS STAIRWAYS & RAMPS ENCLOSED SPACES <br />B B C C <br />A-3 B B C <br />PINKL ER SYSTEM <br />AUTOMATIC SPRINKLER SYSTEM COMPLYING WITH NFPA 13 SHALL BE INSTALLED THROUGHOUT THE <br />AREA OF WORK. (903.3.1.1) EXISTING SPRINKLER SYSTEM AT FACILITTES MAINTENANCE AREA TO <br />REMAIN. <br />PORTABLE FIDE EXTINGUISHERS <br />PORTABLE FIRE EXTINGUISHERS TO BE INSTALLED AS REQUIRED BY 906.1 AND NFPA 10. MAXIMUM <br />TRAVEL DISTANCE TO FIRE EXTINGUISHER TO BE 75FOR LIGHT (LOW) HAZARD OCCUPANCY PER <br />TABLE 906.3(1). <br />FIRE ALARM SYSTEM <br />FIRE ALARM AND DETECTION SYSTEM IN ACCORDANCE WITH NFPA 72 SHALL BE INSTALLED. <br />10 MEANS OF EGRESS <br />LEVEL 01: TOTAL: 740 OCCUPANTS <br />LEVEL 02: TOTAL: 450 OCCUPANTS <br />TOTAL - RANTS <br />O L OCCUPANTS IN SCOPE OF WORK; 1,190 OCCUPANTS <br />FACILITIES MAINTENANCE: TOTAL:136 OCCUPANTS <br />(EXISTING 1 NOT IN SCOPE) <br />REFER TO FILS PLANS SHEETS G2.01 AND G2.02 FOR OCCUPANT LOAD CALCULATIONS, <br />NUMBER OF EXITS <br />TABLE 1006.3.1 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STONY <br />B <br />LEVEL 01: REQUIRED: 3 <br />PROVIDED: 8 <br />LEVEL 02: REQ <br />UIRED: QUIRED: 2 <br />PROVIDED: 4 <br />MEANS OF EGRESS ILLUMINATION <br />1008.1: REFER TO ELECTRICAL DRAWINGS FOR EGRESS ILLUMINATION LIGHTING LEVELS, <br />COVERAGE, AND EMERGENCY POWER SYSTEM <br />AREAS OF REFUGE <br />1009.3 STAIRWAYS <br />EXCEPTION 4: AREAS OF REFUGE ARE NOT REQUIRED AT EXIT ACCESS STAIRWAYS WHERE <br />TWO-WAY COMMUNICATION IS PROVIDED AT THE ELEVATOR LANDING PER 1009.8. <br />EXCEPTION 5: AREAS OF REFUGE ARE NOT REQUIRED AT STAIRWAYS IN BUILDINGS EQUIPPED <br />THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH <br />903.3.1.1. <br />EXISTING INTERIOR EXIT STAIRWAYS <br />2015 INTERNATIONAL FIRE CODE, SECTION 1104.10 STAIR DIMENSIONS FOR EXISTING STAIRS <br />EXISTING STAIRWAYS IN BUILDINGS SHALL BE PERMITTED TO REMAIN IF THE RISE DOES NOT <br />EXCEED 8-1/4 INCHES AND THE RUN IS NOT LESS THAN 9 INCHES. <br />EXISTING STAIR DIMENSIONS RISER HEIGHT TREAD LENGTH <br />STAIR S-2 7,434" 105' <br />STAIR S-3 7,434" 10.51, <br />STAIR S-4 7,125" 11.01, <br />STAIR S-5 7.125" 11 A" <br />NUMBER BE OF STORIES <br />TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE <br />OCCUPANCY GROUPS TYPE_ I11-37 <br />B, S-2 4 <br />A-3, F-1 3 <br />NUMBER OF STORIES: 2 (EXISTING) <br />OCCUPANCY GROUP AREA SUMMARY <br />TABULAR ALLOWABLE AREA <br />ALLOWABLE AREA FACTOR (TABLE 506.2): BASE GSF (NS): BASE GSF (SM): <br />TYPE III-B - A-3 OCCUPANCY 9,500 GSF 28,500 GSF <br />TYPE III-B - B OCCUPANCY 19,000 GSF 57,000 GSF <br />TYPE III-B - F-1 OCCUPANCY 12,000 GSF 36,000 GSF <br />TYPE III-B - S-2 OCCUPANCY 26,000 GSF 78,000 GSF <br />TABULAR ALLOWABLE AREA FOR MIXED -OCCUPANCY, MULTISTORY BUILDING (506.2.4): <br />Aa = [At + (NS x If )] WHERE: <br />OCCUPANCY <br />At = 57,000 <br />If = [FIP-.25]WI30 = [I 175/1175-.25]30130 = .75 <br />If = .75 <br />Aa = [At + (NS x If )] ® (57,000 + (19,000 x .75)] m 71,250 GSFISTORY <br />F-1 OCCUPANCY <br />At = 36,000 <br />It = [F/P-.25]W130 = [I17511175-.25]30130 = .75 <br />If = .75 <br />Aa �: [At + (NS x If )] 136,000 + (12,000 x ,75)] = 45,000 GSF/STORY <br />S-2 OCCUPANCY <br />At = 78,000 <br />If = [F/P-.251W130 = [1175/1175-.25]30/30 = .75 <br />If = .75 <br />Aa m [At + (NS x If )] 178,000 + (26,000 x ,75)) 4 97,500 GSF/STORY <br />BUILDING AREA SUMMARY <br />OCCUPANCY GROUP <br />B <br />A-3 <br />TOTALS <br />AREA OF RENOVATION <br />LEVEL II <br />Ff331,866GSF <br />3,460 GSF <br />35,.326 GSF <br />LEVEL 2 <br />848 GSF <br />33 996 GSF <br />SUBTOTAL <br />66,014 GSF <br />4,308 GSF <br />70,322 GSF <br />OCCUPANCY GROUP <br />B <br />F-1 5-2 <br />FACILITIES MAINTENANCE <br />(NOT IN SCOPE) <br />LEVEL 1 <br />6,856 GSF <br />16,340 GSF <br />23,196 GSF <br />LEVEL 2 <br />5,929 GSF <br />5,929 GSF <br />SUBTOTAL <br />6,856 GSF <br />16,340 GSF 5,929 GSF <br />29,125 GSF <br />TOTAL BUILDING AREA <br />99,447 GSF <br />RATIO OF DESIGNED AREA TO ALLOWABLE AREA <br />508.2 ALLOWABLE BUILDING AREA: <br />IN EACH STORY, THE SUM OF THE RATIOS OF ACTUAL BUILDING AREAS DIVIDED BY THE <br />ALLOWABLE SHALL NOT EXCEED 1. <br />GROUP B: MAIN OCCUPANCY <br />ACCESSORY (A-3) <br />31,866 <br />3,460 <br />B <br />FAC MAINTEN NCEt <br />6.856 <br />42,182 / 71,250 = <br />.59 <br />GROUP F-1: FAC MAINT <br />16,340 / 45,000 = <br />.36 <br />95 < 1 =COMPLIES <br />LEVEL 2 DESIGN / ALLOWABLE <br />GROUP IB: MAIN OCCUPANCY <br />34,148 <br />FAC MAINTENANCE <br />- <br />6 856 <br />314,9961 71,250 = <br />.49 <br />GROUPS-2: FAC MAINT <br />5,929/ 97,500 = <br />.06 <br />.55 < 1 = COMPLIES <br />LEVEL 1 + LEVEL 2 = ,95 ¢ .55 a 1.50 < 2 = COMPLIES <br />I <br />FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS <br />TABLE 601 <br />BUILDING ELEMENT <br />TYPE III-B REQUIRED <br />PROVIDED <br />PRIMARY STRUCTURAL FRAME <br />OHR <br />OHR <br />EXTERIOR BEARING WALLS <br />2 HR <br />2 HR <br />INTERIOR BEARING WALLS <br />OHR <br />0 HR <br />STRUCTURAL FRAME SUPPORTING <br />ROOF ONLY OHR <br />OHR <br />FLOORS & SECONDARY MEMBERS <br />OHR <br />OHR <br />ROOF CONSTRUCTION <br />OHR <br />OHR <br />NON -BEARING INTERIOR WALLS <br />OHR <br />OHR <br />NON -BEARING EXTERIOR WALLS <br />0 HR (TABLE 602) <br />OHR <br />FIRE RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS <br />TABLE 602 TYPE III-B <br />OCCUPANCY OCCUPANCY <br />PROVIDED <br />FIRE SEPARATION DISTANCE <br />B, A-3, 8-2 F-1 (NIC) <br />X<5 <br />1 HR 2HR <br />5<X<10 <br />1 HR 1 HR <br />10<X<30 <br />1 HR 1 HR <br />X>30 <br />OHR OHR <br />OHR <br />FIRE SEPARATION DISTANCE GREATER THAN 30'-0" AT ALL SIDES, <br />SEE SITE PLAN SHEET G4.01, <br />THE PROPOSED PROJECT WILL RENOVATE THE EXISTING BUILDING AT 2312 W CASINO ROAD AND <br />INCLUDES EXTENSIVE INTERIOR RENOVATIONS, EXTERIOR IMPROVEMENTS AND TWO SMALL <br />ADDITIONS, AND SITE WORK TO IMPROVE ON -SITE PARKING AND TRAFFIC FLOW. <br />INTERIOR RENOVATIONS INCLUDE BUSINESS OFFICES AND ASSOCIATED CONFERENCE ROOMS, <br />RECORDS STORAGE, AND SUPPORT SPACES; PARTIAL DEMOLITION OF THE SECOND FLOOR FORA <br />TWO-STORY INTERIOR SPACE; A STADIUM STAIR f SEATING AREA; REMOVAL AND REPLACEMENT OF <br />THE EXISTING FAILING ELEVATOR; ADDITION OF A SECOND SERVICE ELEVATOR; AND STRUCTURAL <br />RETROFIT TO ENSURE SEISMIC PERFORMANCE. <br />EXTERIOR IMPROVEMENTS INCLUDE A TWO-STORY MAIN ENTRANCE VESTIBULE ADDITION; A ONE- <br />STORY ADDITION WITH ROOF DECK AT THE EMPLOYEE ENTRANCE; AREAS OF CONCRETE PANEL <br />REMOVAL FOR NEW STOREFRONT AND EXPANDED WINDOW OPENINGS; AND EXPANSIVE SKYLIGHTS. <br />SITE WORK INCLUDES A NEW RAISED PLAZA AT THE NORTH AND EAST SIDES OF THE BUILDING; <br />ADDITIONAL PARKING SPACES INCLUDING ACCESSIBLE SPACES AND EV CHARGING STATIONS; NEW <br />LOCATIONS FOR TRANSFORMER; GENEPATOR, AND FIRE DEPARTMENT CONNECTION; AND STORM <br />WATER MANAGEMENT SYSTEM. <br />THE RENOVATION DOES NOT INCLUDE THE EXISTING FACILITIES MAINTENANCE DEPARTMENT WHICH <br />OCCUPIES THE SOUTH END OF THE FIRST FLOOR AND MEZZANINE AND WILL REMAIN IN OPERATION <br />THROUGH THE CONSTRUCTION WORK. (PLAN CHECK NO. B0906-043, 2009) <br />RELEVANT CODES ZONING <br />BUILDING CODE; 2015 INTERNATIONAL BUII DING COQE (IBC) WITH AMENDMENTS (WAC 51 50) AND <br />B 2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC) W1 AMENDMENTS (WAC 51-50) <br />MECHANICAL CODE: 2015 INTERNATIONAL MECHANICAL CODE (IMC) WITH AMENDMENTS (WAC 51-52) <br />PLUMBING CODE: 2015 UNIFORM PLUMBING CODE WITH AMENDMENTS (WAC 51-56) <br />ELECTRICAL CODE: 2014 NATIONAL ELECTRICAL CODE (NEC) <br />FUEL GAS CODE: 2015 NATIONAL FUEL GAS CODE (NFPA 54) WITH AMENDMENTS (WAC 51-52-21000) <br />FIRE CODE: 2015 INTERNATIONAL FIRE CODE (IFC) WITH AMENDMENTS (WAG 51-54A) <br />ENERGY CODE: 2015 WASHINGTON STATE ENERGY CODE COMMERCIAL, APPENDIX (WAC 51-11C) <br />PETROLEUM GAS CODE: 2014 LIQUIFIED PETROLEUM GAS CODE (NFPA 58) <br />PROPERTY MAINTENANCE CODE: 2015 INTERNATIONAL PROPERTY MAINTENANCE CODE <br />ACCESSIBLITY: ICC/ANSI Al17.1-2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES <br />STORMWATER: WASHINGTON STATE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT <br />MANUAL FOR WESTERN WASHINGTON <br />DESIGN STANDARDS: CITY OF EVERETT DESIGN AND CONSTRUCTION STANDARDS AND <br />SPECIFICATIONS MANUAL <br />ZONING CODE: EVERETT MUNICIPAL CODE (2/5/2020) <br />1101111k, WIN] <br />f <br />MECHANICAL SCREENING ® CHAPTER 19.28 <br />19.28.020 ADDITIONAL STANDARDS FOR USES IN THE M-M ZONE <br />A.2 MECHANICAL EQUIPMENT SCREENING <br />MODkFICATION OF THE ARCHITECTURAL SCREENING REQUIREMENT TO BE APPROVED THROUGH THE <br />CONSTRUCTION PERMIT REVIEW PER GRACE POLLARD EMAIL DATED 2/12/2020, NO LAND USE <br />APPLICATION REQUIRED, ROOFTOP UNITS WILL BE PAINTED TO MATCH THE BUILDING AND ENSURE <br />NO SHINE OR GLARE. ROOFTOP DUCTING MAY NOT BE VISIBLE, <br />PARKING SUMMARY - CHAPTER 19.34 <br />TABLE 34.1: OFF-STREET PARKING SPACES REQUIRED <br />ADMINISTRATIVE OFFICES (GENERAL OFFICE) -1 PER 400 SF 176 SPACES REQUIRED <br />FACILITIES MAINTENANCE (LIGHT INDUSTRIAL) -1 PER 750 SF 39 SPACES REQUIRED <br />TOTAL REQUIRED = 215 <br />TOTAL PROVIDED = 243 <br />REQUIRED ACCESSIBLE PARKING (TABLE 1106.1) = 7 <br />ACCESSIBLE PARKING PROVIDED = 7 (INCLUDES 2 VAN ACCESSIBLE) <br />d �• <br />OCCUPANCY GROUPS <br />tB: ADMINISTRATIVE OFFICES, CONFERENCE ROOMS, SUPPORT SPACES, AND AMENITIES <br />A-3: CONFERENCE CENTER, STADIUM SEATING <br />F-1: FACTORY/WAREHOUSE (EXISTING FACILITIES MAINTENANCE) <br />5 2: LOW HAZARD STORAGE (EXISTING FACILITIES MAINTENANCE) <br />STAGES, PLATFORMS AND TECHNICAL PRODUCTION CTION SPACES <br />410.4 PLATFORM CONSTRUCTION <br />PRESENTATION PLATFORM TO BE NOT MORE THAN 30" ABOVE MAIN FLOOR, NOT MORE THAN <br />ONE-THIRD OF THE ROOM FLOOR AREA, AND NOT MORE THAN 3,000 SF, SPACE BENEATH <br />PLATFORM SHALL NOT BE USED FOR STORAGE. <br />, In, MM \ 1 <br />4 <br />CONSTRUCTION TYPE: III-B, FULLY SPRINKLERED <br />PREVIOUSLY CLASSIFIED AS TYPE V-B UNDER PERMIT #80906-03 <br />BUILDING I HT <br />TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLAN_ E <br />OCCUPANCY GROUPS TYPE I11- <br />A, B, F, S 75 FT <br />BUILDING HEIGHT (EXISTING) <br />GRADE TO FINISH FLOOR (EAST SIDE) 1' 6" <br />FINISH FLOOR TO TOP OF PARAPET 29' -10" <br />TOTAL BUILDING HEIGHT 91' - 4" <br />(NOT INCLUDING MECHANICAL SCREENS OR EQUIPMENT) <br />I I I „aV '-l`1ited5, ivi . <br />s- <br />SC ��. � ` . hM Av �ue, Ste 800 <br />P rtl ' O R T2C4 <br />.287.CS25 <br />4� <br />v <br />f , Ty'Ai. <br />y. <br />Gy <br />[tiFfIII <br />06/01/2020 <br />CONSULTANT <br />TITLE <br /># DATE DESCRII <br />B 05/20/2020 PERMIT F <br />D 06/01/2020 PLAN REi <br />'TION <br />EVIEW 1 <br />ISIONS <br />REVISIONS <br />KE, MS JG <br />DRAWN BY CHECK BY <br />100% ISSUE SET/BID SET <br />STATUS <br />04/17/2020 <br />DATE <br />328801 <br />PROJECT NUMBER <br />G1 mOl <br />Q 2020 OTAK, INC, - <br />If this drawing is not 24" x 36 ", it has been <br />reducedlenlarged. Scale accordingly. <br />