Laserfiche WebLink
I <br />SCALE: 1/8" = 1'4' <br />I <br />24' - 6" <br />-- / 1 Q4 104 " i v e <br />8„ A8.12 SIM 9 4 10' - 81, SIM A8.12 A8.1 3' 4„ 121 <br />Sim <br />D D B <br />kl�V ( <br />I <br />1. ALL DIMENSIONS ARE TO FACE OF FRAMING, FACE OF SLAB, <br />CENTERLINE OF COLUMN, CENTERLINE OF OPENING, AND TO <br />FACE OF EXISTING FINISH WHERE REMAINING, UNLESS NOTED <br />OTHERWISE. DIMENSIONS TO EXISTING REFERENCES SHALL BE <br />VERIFIED IN FIELD AND THE ARCHITECT NOTIFIED OF ANY <br />DISCREPANCIES. <br />2. GRID LINES INDICATE FACE OF EXISTING CONCRETE TILT -UP <br />PANEL AND CENTERLINE OF COLUMNS. <br />3. SIDEWALKS AND PATIOS SHALL SLOPE AT 2% MAXIMUM AS <br />SHOWN ON PLANS. WARP CONCRETE AT WALLS AND COLUMNS <br />AS SHOWN TO FORCE WATER TO MIGRATE AWAY FROM AND <br />AROUND WITHOUT EXCEEDING 1.5% MAXIMUM SLOPE. <br />4. SEE SHEET A1.01 FOR TYPICAL CONSTRUCTION ASSEMBLY <br />DESCRIPTIONS. <br />5. SEE SHEET A8.14 FOR FIRE -RATED ASSEMBLY INTERSECTION <br />DETAILS. <br />6, SEE SHEET A1.11 FOR DOOR TYPES AND SCHEDULE. <br />7. SEE EXTERIOR ELEVATIONS FOR EXTERIOR WINDOW <br />DESIGNATIONS AND SHEET A1.12 FOR GLAZING TYPES. <br />8. INDICATES INTERIOR RELITE. REFER TO SHEET A1.12 FOR <br />ELEVATION AND WIDTHS. <br />9, SEE INTERIORS SHEETS FOR FINISH PLANS AND ROOM FINISH <br />SCHEDULES. <br />10. OPERABLE PARTS OF LIGHTING, ENVIRONMENTAL, ELECTRICAL, <br />SECURITY CONTROLS, AND ELECTRICAL RECEPTACLES SHALL <br />BE MOUNTED BETWEEN 15" AND 48" ABOVE FINISHED FLOOR. <br />SEE SHEET G3.01 FOR ADDITIONAL TYPICAL ACCESSIBLE <br />REQUIREMENTS. <br />11, EVERY ROOM OR SPACE THAT IS AN ASSEMBLY USE SHALL <br />HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED <br />IN A CONSPICUOUS PLACE. <br />12. ROOMS CONTAINING FIRE PROTECTION SYSTEMS OR <br />EQUIPMENT SHALL BE IDENTIFIED IN AN APPROVED MANNER. <br />SIGNS SHALL BE CONSTRUCTED OF DURABLE MATERIALS, <br />PERMANENTLY INSTALLED AND READILY VISIBLE. DOORS INTO <br />ELECTRICAL CONTROL PANEL ROOMS SHALL BE MARKED WITH A <br />PLAINLY VISIBLE AND LEGIBLE SIGN STATING "ELECTRICAL <br />ROOM". <br />13. FINISHED FACE OF NEW WALLS TO ALIGN WITH EXISTING WALL <br />FACE WHERE INDICATED. FINISH TO BE FLUSH WITH AND MATCH <br />EXISTING ADJACENT WALL FINISH WHERE WALLS ABUT. <br />EXISTING WALL <br />1-HR RATED WALL <br />I FIRE EXTINGUISHER <br />{FEGI <br />j CABINET <br />— — — — — - FLOOR OPENING + <br />SKYLIGHT ABOVE <br />102 (E) OPENING EXTENDED TO FLOOR FOR NEW PASSAGEWAY, <br />PATCH FLOOR FOR SMOOTH, LEVEL TRANSITION. SEE <br />DETAILS SHEET A8.11. <br />104 INF►LL (E) OPENING W/ METAL FRAMING, 5/8" GYP BOARD EA <br />SIDE. ALIGN GYP BOARD W/ INSIDE CORNER OF CHAMFER AT <br />EXPOSED AGGREGATE SIDE. SEE DETAIL 5/A8.12. <br />105 DRINKING FOUNTAIN/BOTTLE FILLER, SEE PLUMBING DWGS. <br />106 SEE INTERIORS DWGS FOR RECEPTION DESK AND OTHER <br />CASEWORK. <br />109 EMERGENCY GENERATOR & FUEL TANK. REFERENCE <br />ELECTRICAL DWGS. <br />111 EXISTING INFIL L AT CONCRETE OPENING TO REMAIN. <br />113 NEW 1-1/4" METAL PIPE HANDRAIL 36" ABOVE STAIR NOSING. <br />114 INSTALL 5/8" PLYWOOD BACKER BOARD OVER GYP BOARD TO <br />8' A.F.F. AT WALLS INDICATED, PAINT TO MATCH WALLS PER <br />FINISH SCHEDULE, <br />121 INFILI_ (E) OPENING WITH NEW CONCRETE, SEE DETAIL 4/A8.12 <br />AND REFERENCE STRUCTURAL DWGS, <br />127 GLASS PARTITION/PONY !HALL. <br />X-hitects Inc. <br />Alan-,% OR D72x�1, <br />2ST 6825 <br />Vim` otak.co <br />4 <br />O IA N It <br />I ` <br />1 t ASff,`T,3TQ <br />/2 /2020 <br />STAMP <br />CONSULTANT <br />0 <br />0 <br />Lij <br />0 <br />ce <br />CA <br />0 <br />N <br />TITLE <br /># DATE <br />DESCRI <br />A 04/17/2020 PLAN RE <br />B 05/20/2020 <br />PERMIT[ <br />REVISIONS <br />w <br />PTION <br />/ISIONS <br />tEVIEW 1 <br />KE, CD, DP MS, JG, WY <br />DRAWN BY CHECK BY <br />100% ISSUE SET/BID SET <br />STATUS <br />04/17/2020 <br />DATE <br />328801 <br />PROJECT NUMBER <br />A2. 01 a <br />@ 2020 OTAK, INC. <br />If this drauving is not 24" x 36" it has been <br />reduced/enlarged. Scale accordingly. <br />