My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2312 W CASINO RD 2020 COMMUNITY TRANSIT Plans 2022-12-02
>
Address Records
>
W CASINO RD
>
2312
>
COMMUNITY TRANSIT
>
Plans
>
2312 W CASINO RD 2020 COMMUNITY TRANSIT Plans 2022-12-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2022 12:24:46 PM
Creation date
5/10/2022 4:28:38 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
2312
Tenant Name
COMMUNITY TRANSIT
Permit
B2003-012
Year
2020
Notes
EXISTING BUILDING RENOVATED INTO NEW ADMINISTRATIVE OFFICE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
156
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />I71 <br />0 <br />N <br />CJ <br />N <br />of <br />a <br />cc <br />r <br />4'-8„ <br />F�- <br />)88A ; <br />16 ALIGN — <br />-1 7' - 3 1 /4" <br />APPLICANT <br />TESTING <br />� <br />i <br />1a3 <br />OPEN OFFICE <br />it <br />�r <br />,. <br />r— <br />4 <br />. <br />- <br />OPEN <br />{ <br />CONFERENCE <br />FEC <br />( <br />- 6 1 /2' 6' - 2" <br />122 <br />24' - 8" <br />u Q <br />LEVEL 01 - FLOOR PLAN - B <br />NMI <br />$� <br />CORRIDOR <br />� a87 <br />10'-8" <br />7'-11" <br />1 <br />A6.03 LARGE CONF 16 (E) RISER <br />�� 077 11 r - <br />OPEN CONF <br />086 <br />�j�� - <br />> <br />5'- 2"' <br />( <br />B <br />> SMALL COIF 'e <br />_ 094 I <br />-116' <br />21 �21 i16; ( I <br />14 21 _ I <br />- - -- - 085 I <br />I <br />084A <br />A <br />OFFICE OFFICE 1 I/ I - VENDING 1611 12A <br />i 107 <br />ca 6 --- 083 - <br />113 _ ag2 ti -_ <br />-- <br />( SM CON 134 <br />116 16 O 09 A6.a3 I1 _l l �� 1 16 <br />113 =402 I - -- _ J I 12 I <br />oc r - <br />�4 ; <br />f tQ? WELLNESS ( '' ( 1 13 10 LJLI <br />SIM <br />1 OFFICE OFFICE 1 - I i ELEV �` 15 as.� BREAK AREA I BREAK AREA 1 <br />O 16 , ( • (ELEV EQ STo <br />112 ag3 'PHONE <br />3 131 133 <br />PH NE <br />16 j 16� <br />16 u 1 <br />- <br />T <br />M � REATMENT 2— <br />^_- <br />__ <br />i <br />( <br />�_ ( I g' ag6 A6.05 i 15 j 13 ( 13.A �12� 16 i <br />� 17� ( ;12A j 12 CORRIDOR ( <br />SMALL I <br />CONFERENCE COPYf PRINT —j126 12 <br />111 110 UPS 13A fl <br />( .( <br />LAUNDRY JANITOR f STOR <br />FITNESS -' 12 <br />a I � 118 125 ( 126 ( agg 126 I 128 I j <br />1626� * � <br />B; 414 ( �. <br />�- 12B <br />110 -- ., 105 (. . <br />-- -- 118 _—_,. ( a <br />12'-51/4" 4'-93/4" 7'-11" 5'-2" Q (. <br />e r C 1 - 5'- 2" 6' - 0" 6-3" 7' - 1 1/4' 1 i <br />CORRIDOR <br />16 17 1 16 16 i m( 6 I I <br />16 123 A6.a5 _ <br />-------Ir <br />----------- -------., <br />' 129B <br />(. <br />¢ <br />116 ,. m <br />t- <br />71 <br />10' - 8 3/4 <br />R <br />WOMEN S , e I MEWS <br />115 FEC 114 <br />4 17 I 11g _ 121 <br />I <br />N 112 r-- <br />108 <br />O- - - -- -- <br />`A MEN'S SHWR FITNESS - - i 110 <br />I STORAGE( WOMEN'S <br />MECHANICAL DATA CENTER ; ` ( STUDIO 12 , <br />WORKILAE� SHWR 122 1 -- <br />1 BIKE ROOM <br />117 I 13a <br />( Q ( 119 132 <br />115 -91, <br />( <br />114=1 6I - <br />I <br />122 <br />20B1 ( ( ( 42Q <br />[16 <br />LARGE CONE <br />a89 <br />16 <br />OFFICE OFFICE <br />115 a90 <br />16 16 <br />OFFICE OFFICE <br />114 ag1 <br />124 <br />2 <br />1.07 <br />24' - 8" <br />123 <br />Fd <br />24' - 8" <br />24' - 8" <br />1 <br />24' - 8" <br />01 <br />15'-0" <br />c� <br />F_ <br />U) <br />w <br />(D <br />BUILDING PLAN NOTES <br />1. ALL DIMENSIONS ARE TO FACE OF FRAMING, FACE OF SLAB, <br />CENTERLINE OF COLUMN, CENTERLINE OF OPENING, AND TO <br />FACE OF EXISTING FINISH WHERE REMAINING, UNLESS NOTED <br />OTHERWISE. DIMENSIONS TO EXISTING REFERENCES SHALL BE <br />VERIFIED IN FIELD AND THE ARCHITECT NOTIFIED OF ANY <br />DISCREPANCIES. <br />2. GRID LINES INDICATE FACE OF EXISTING CONCRETE TILT -UP <br />PANEL AND CENTERLINE OF COLUMNS. <br />3. SIDEWALKS AND PATIOS SHALL SLOPE AT 2% MAXIMUM AS <br />SHOWN ON PLANS, WARP CONCRETE AT WALLS AND COLUMNS <br />AS SHOWN TO FORCE WATER TO MIGRATE AWAY FROM AND <br />AROUND WITHOUT EXCEEDING 1.5% MAXIMUM SLOPE. <br />4. SEE SHEET A1.01 FOR TYPICAL CONSTRUCTION ASSEMBLY <br />DESCRIPTIONS. <br />5. SEE SHEET A8.14 FOR FIRE -RATED ASSEMBLY INTERSECTION <br />DETAILS. <br />6. SEE SHEET A1.11 FOR DOOR TYPES AND SCHEDULE. <br />7, SEE EXTERIOR ELEVATIONS FOR EXTERIOR WINDOW <br />DESIGNATIONS AND SHEET A1.12 FOR GLAZING TYPES. <br />8. O INDICATES INTERIOR RELITE, REFER TO SHEET A1.12 FOR <br />ELEVATION AND WIDTHS. <br />9. SEE INTERIORS SHEETS FOR FINISH PLANS AND ROOM FINISH <br />SCHEDULES. <br />10. OPERABLE PARTS OF LIGHTING, ENVIRONMENTAL, ELECTRICAL, <br />SECURITY CONTROLS, AND ELECTRICAL RECEPTACLES SHALL <br />BE MOUNTED BETWEEN 15" AND 48" ABOVE FINISHED FLOOR. <br />SEE SHEET G3.01 FOR ADDITIONAL TYPICAL ACCESSIBLE <br />REQUIREMENTS. <br />11. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY USE SHALL <br />HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED <br />IN A CONSPICUOUS PLACE. <br />12. ROOMS CONTAINING FIRE PROTECTION SYSTEMS OR <br />EQUIPMENT SHALL BE IDENTIFIED IN AN APPROVED MANNER. <br />SIGNS SHALL BE CONSTRUCTED OF DURABLE MATERIALS, <br />PERMANENTLY INSTALLED AND READILY VISIBLE, DOORS INTO <br />ELECTRICAL CONTROL PANEL ROOMS SHALL BE MARKED WITH A <br />PLAINLY VISIBLE AND LEGIBLE SIGN STATING "ELECTRICAL <br />ROOM". <br />13. FINISHED FACE OF NEW WALLS TO ALIGN WITH EXISTING WALL <br />FACE WHERE INDICATED. FINISH TO BE FLUSH WITH AND MATCH <br />EXISTING ADJACENT WALL FINISH WHERE WALLS ABUT. <br />FLOOR PLAN LEGEND <br />C_,- EXISTING WALL <br />1-HR RATED WALL <br />r --1 FIRE EXTINGUISHER <br />FF.ff-- <br />CABINET <br />_ _ _ _ _ - _ FLOOR OPENING + <br />SKYLIGHT ABOVE <br />KEYNOTE LEGEND <br />101 INFILL OPENING TO MATCH EXISTING WALL CONSTRUCTION, <br />THICKNESS, AND SURFACE MATERIALS. FINISH SMOOTH AND <br />CONSISTENT WITH ADJACENT SURFACES. <br />105 DRINKING FOUNTAIN/BOTTLE FILLER, SEE PLUMBING DWGS. <br />107 VENDING MACHINE BY OWNER. <br />108 WALL MOUNTED TEAK BENCH. <br />110 15" X 15" METAL LOCKERS, 5 TIERS HIGH. <br />113 NEW 1-1/4" METAL PIPE HANDRAIL 36" ABOVE STAIR NOSING, <br />114 INSTALL 5/8" PLYWOOD BACKER BOARD OVER GYP BOARD TO 8' <br />A.F.F. AT WALLS INDICATED, PAINT TO MATCH WALLS PER <br />FINISH SCHEDULE. <br />115 INSTALL 5/8" PLYWOOD BACKER BOARD OVER GYP BOARD TO <br />UNDERSIDE OF STRUCTURE AT WALLS INDICATED. PAINT TO <br />MATCH WALLS PER FINISH SCHEDULE. <br />116 INSTALL 5/8" PLYWOOD ABOVE AND BETWEEN CASEWORK THIS <br />WALL. <br />119 WALL MOUNTED OFFSET BIKE RACKS (14 BIKES HANGERS <br />TOTAL), <br />120 FLOOR MOUNTED HOOP STYLE BIKE RACK. <br />122 INFILL TO MATCH EXISTING SURROUNDING WALL <br />CONSTRUCTION. INSTALL ADDITIONAL FRAMING, INSULATION, <br />AND GYP BOARD PER WALL ASSEMBLY INDICATED. FINISH <br />SMOOTH AND CONSISTENT WITH ADJACENT SURFACES. <br />123 EXISTING DOOR AND FRAME REINSTALLED IN EXISTING <br />LOCATION. <br />124 REPLACE WALL IN EXISTING LOCATION. MATCH EXISTING WALL <br />CONSTRUCTION, THICKNESS, AND SURFACE MATERIALS. <br />FINISH SMOOTH AND CONSISTENT WITH ADJACENT SURFACES. <br />129 INSTALL METAL STUD FURRING AND 5/8" GYP BOARD TO <br />ENCLOSE NEW PIPING, ALIGN WITH AND MATCH FINISH OF <br />ADJACENT SURFACES. <br />KEY PLAN <br />_CITY OF EVERF7`1` <br />a' 4' 8' 16' <br />0 <br />k i 771 <br />I <br />7.29.2020 <br />STAMP <br />CONSULTANT <br />z <br />0 <br />F— <br />0 <br />z <br />LLJ <br />0 <br />Q g <br />o0 <br />� <br />Li 00 <br />a <br />0) <br />Q Q <br />z <br />I" <br />CU <br />W <br />Qa <br />ry <br />N W <br />LJ <br />N W <br />TITLE <br /># DATE DESCRI <br />A 04/17/2020 PLAN RE' <br />B 05/20/2020 PERMIT F <br />C 05/20/2020 PLAN RE' <br />E 07/29/2020 PERMIT F <br />0 <br />LLJ <br />LLJ <br />'TI ON <br />/ISIONS <br />,EVI EW 1 <br />/ISIONS <br />;EVI EW 2 <br />REVISIONS <br />KE, CD, DP MS, JG, WY <br />DRAWN BY CHECK BY <br />100% ISSUE SET/BID SET <br />STATUS <br />04/17/2020 <br />DATE <br />328801 <br />PROJECT NUMBER <br />A2001 b <br />O 2020 OTAK, INC. <br />If this drawing is not 24"x 36", it has been <br />reducedlenlarged. Scale accordingly. <br />SCALE: 1/8" = l'-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.