Laserfiche WebLink
A3.04 2 <br />MATCHLINE <br />SEE 1/A2.02a <br />SEE 1 /A2.02b <br />LEVEL <br />02 FLOOR i OVERALL <br />f <br />SCALE: 1/16" = 1 -0" <br />MATCHLINE <br />SEE 1/A2 02a <br />SEE 1/A2 02b <br />BUILDING PLAN NOTES <br />1. ALL DIMENSIONS ARE TO FACE OF FRAMING, FACE OF SLAB, <br />CENTERLINE OF COLUMN, CENTERLINE OF OPENING, AND TO <br />FACE OF EXISTING FINISH WHERE REMAINING, UNLESS NOTED <br />OTHERWISE, DIMENSIONS TO EXISTING REFERENCES SHALL BE <br />VERIFIED IN FIELD AND THE ARCHITECT NOTIFIED OF ANY <br />DISCREPANCIES, <br />2. GRID LINES INDICATE FACE OF EXISTING CONCRETE TILT -UP <br />PANEL AND CENTERLINE OF COLUMNS. <br />3. SIDEWALKS AND PATIOS SHALL SLOPE AT 2% MAXIMUM AS <br />SHOWN ON PLANS. WARP CONCRETE AT WALLS AND COLUMNS <br />AS SHOWN TO FORCE WATER TO MIGRATE AWAY FROM AND <br />AROUND WITHOUT EXCEEDING 1.5% MAXIMUM SLOPE. <br />4, SEE SHEET A1.01 FOR TYPICAL CONSTRUCTION ASSEMBLY <br />DESCRIPTIONS. <br />5, SEE SHEET A8.14 FOR FIRE -RATED ASSEMBLY INTERSECTION <br />DETAILS. <br />6. SEE SHEET A1.11 FOR DOOR TYPES AND SCHEDULE. <br />7. SEE EXTERIOR ELEVATIONS FOR EXTERIOR WINDOW <br />DESIGNATIONS AND SHEET A1.12 FOR GLAZING TYPES. <br />3. �INDICATES INTERIOR RELITE. REFER TO SHEET A1.12 FOR <br />ELEVATION AND WIDTHS. <br />9. SEE INTERIORS SHEETS FOR FINISH PLANS AND ROOM FINISH <br />SCHEDULES. <br />10. OPERABLE PARTS OF LIGHTING, ENVIRONMENTAL, ELECTRICAL, <br />SECURITY CONTROLS, AND ELECTRICAL RECEPTACLES SHALL <br />BE MOUNTED BETWEEN 15" AND 48" ABOVE FINISHED FLOOR. <br />SEE SHEET G3.01 FOR ADDITIONAL TYPICAL ACCESSIBLE <br />REQUIREMENTS. <br />11. EVERY ROOM OR SPACE THAT IS AN ASSEMBLY USE SHALL <br />HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED <br />IN A CONSPICUOUS PLACE. <br />12. ROOMS CONTAINING FIRE PROTECTION SYSTEMS OR <br />EQUIPMENT SHALL BE IDENTIFIED IN AN APPROVED MANNER. <br />SIGNS SHALL BE CONSTRUCTED OF DURABLE MATERIALS, <br />PERMANENTLY INSTALLED AND READILY VISIBLE. DOORS INTO <br />ELECTRICAL CONTROL PANEL ROOMS SHALL BE MARKED WITH A <br />PLAINLY VISIBLE AND LEGIBLE SIGN STATING "ELECTRICAL <br />ROOM". <br />13. FINISHED FACE OF NEW WALLS TO ALIGN WITH EXISTING WALL <br />FACE WHERE INDICATED, FINISH TO BE FLUSH WITH AND MATCH <br />EXISTING ADJACENT WALL FINISH WHERE WALLS ABUT. <br />l .IMMUNE € i <br />-. EXISTING WALL <br />-� 1-HR RATED WALL <br />FEC _ -1 FIRE EXTINGUISHER <br />CABINET <br />FLOOR OPENING + <br />SKYLIGHT ABOVE <br />14( ) <br />A�.02 <br />__ <br />2 <A3.02 <br />17'N1 <br />Ok -hite s, Inc <br />808 SW i rd Av `_ue, Ste 00 <br />PI o an 'Jan OR72C <br />.2 1,BB2 <br />atak.corn <br />CONSULTANT <br />TITLE <br /># DATE DESCRII <br />A 04/17/2020 PLAN RED <br />B 05/20/2020 PERMIT F <br />REVISIONS <br />9 <br />CL <br />'TION <br />'ISIONS <br />EVIEW 1 <br />Author Checker <br />DRAWN BY CHECK BY <br />100% ISSUE SET/BID SET <br />STATUS -__-- <br />04/17/2020 <br />DATE <br />326601 <br />PROJECT NUMBER <br />G <br />Q, <br />h <br />0 2020 OTAK, INC. <br />ff this drawing is not 24"x 36", it has been <br />reduced/enlarged. Scale accordingly. <br />