Laserfiche WebLink
m <br />CN <br />r— <br />C <br />0 <br />0 <br />G� E1 <br />T_ <br />— -F .® — <br />05 _D5 <br />6„ 20' 0" <br />� I I <br />11 <br />I <br />�I <br />� <br />I <br />I <br />( <br />1 <br />- <br />I� <br />MATCHLINE I <br />, <br />SEE 1/D1 01b�� �� E <br />I <br />I <br />LEVEL e , y ' <br />A <br />SCALE: 1/8" = 1'-0" <br />TF <br />[ I - D2 <br />D2.01 C I I I <br />I <br />C1 I I I B2 81 Al A AA <br />D4 --- __ <br />r::,14'- <br />�;/ , I O7 EXISTING FIRE SPRINKLER RISER <br />1'�m 0" ( I ," / /1 TO REMAIN. SEE FIRE <br />2,, 41- �� � f' ,- ,� _ D 5 <br />' D50 16' 0'" — ® I PROTECTION/PLUMBING DRAWINGS <br />WINGS <br />I / <br />3'- 0„ / ' /I ` ,I �I \ SUP FOR NEW SPRINKLER SYSTEM. <br />M. <br />I <br />DEMOLITION <br />1. CASHED LINES INDICATE OBJECTS TO BE DEMOLISHED AND / OR SALVAGED. <br />2, ITEMS SALVAGED FOR RE -USE SHALL BE SAFELY STORED AND PROTECTED FROM DAMAGE DURING <br />CONSTRUCTION. <br />3. EXISTING FURNITURE, DECORATIVE LIGHTING, & EQUIPMENT NOT TO BE RE -USED. CONTRACTOR TO <br />BE RESPONSIBLE FOR SALVAGING FOR RECYCLING OR DISPOSAL AS REQUIRED. <br />4. REFER TO THE REFLECTED CEILING PLANS FOR ADDITIONAL DEMO NOTES SPECIFIC TO THE EXISTING <br />CEILING CONDITIONS. <br />5. CONTRACTOR IS RESPONSIBLE FOR THE SAFE REMOVAL OF ANY AND ALL MATERIALS REFERRED TO <br />IN THE MED-TOX 2007 HAZARDOUS BUILDING MATERIALS SURVEY. SHOULD THE CONTRACTOR <br />ENCOUNTER ANY ADDITIONAL ASBESTOS MATERIALS, PCB'S, OR OTHER TOXIC SUBSTANCES NOT <br />NOTED IN THE SURVEY, THE CONTRACTOR. SHOULD IMMEDIATELY REPORT THE FINDINGS IN WRITING <br />TO THE BUILDING OWNER &TENANT, PRIOR TO CONTINUING WITH ANY WORK IN THE AREA. WORK <br />SHALT_ NOT BE RESUMED EXCEPT BY WRITTEN AUTHORIZATION OR AGREEMENT FROM THE OWNER. <br />6. EXISTING HVAC EQUIPMENT, PLUMBING, DRAIN & FIRE PROTECTION LINES TO BE DEMOLISHED <br />EXCEPT AS NOTED. REFER TO MECHANICAL AND PLUMBING DEMOLITION DRAWINGS FOR FULL <br />EXTENT OF DEMO. CONTRACTOR SHALL VERIFY EXISTING ITEMS TO REMAIN WITH <br />ARCHITECT/MECHANICAL DESIGNER. COORDINATE WITH PROPERTY PRIOR TO INTERFERING WITH <br />EXISTING UTILITIES. <br />T THE PLANS/ELEVATIONS ARE DERIVED FROM ARCHIVAL BUILDING PLANS & ARE INTENDED TO <br />REASONABLY REPRESENT EXISTING CONDITIONS. ACTUAL CONDITIONS MAY DEVIATE FROM THAT <br />WORK, BUT MAY NOT BE SHOWN N THE DRAWINGS. DEMON NOTES IDENTIFY SPECIFIC AREAS OF 0 0 S o s O s E SEC c I <br />COMPLETE IN THE IDENTIFICATION OF ALL REMOVALS. THE CONTRACTOR SHALL VERIFY ACTUAL <br />CONDITIONS & COORDINATE DEMO WITH NEW WORK SO THAT DEMO IS COMPLETE. <br />8. EXISTING LIGHT FIXTURES AND ELECTRICAL COMPONENTS TO BE REMOVED EXCEPT AS NOTED. <br />REFER TO ELECTRICAL DEMOLITION PLANS FOR FULL EXTENT OF DEMOLITION AND FIXTURES BEING <br />REMOVED. <br />9. EXISTING FINISHES WILL BE REMOVED IN THEIR ENTIRETY WHERE INDICATED AND EXPOSED <br />SURFACES PREPARED FOR NEW FINISHES. <br />10. ALL WORK WHICH IS TO REMAIN SHALL BE PROTECTED FROM DAMAGE AND, IF DAMAGED, SHALL BE <br />REPAIRED AT NO COST TO THE OWNER. PROVIDE DUST ISOLATION & PROTECTION TO LIMIT DUST TO <br />AREAS OF WORK. <br />DEMOLITION LEGEND <br />AREA OF DEMOLITION <br />WALLS TO REMAIN <br />— — — — — ITEM TO BE REMOVED <br />ITEM TO REMAIN <br />`E LEGEND <br />D1 REMOVE (E) CONCRETE PLANTERS. SALVAGE PLANTINGS IN GOOD CONDITION AND RETURN <br />TO OWNER OR DISPOSE OF AS DIRECTED. <br />D2 REMOVE (E) STEEL CANOPY POSTS, FRAMING, ROOF STRUCTURE, AND FOOTINGS. PROTECT <br />EXISTING EXPOSED AGGREGATE CONCRETE TO REMAIN FROM DAMAGE DURING <br />DEMOLITION. <br />D3 REMOVE (E) CONCRETE SIDEWALKAND PAVING AS REQUIRED FOR NEW ENTRY ADDITION, <br />SEE LANDSCAPE/CIVIL DRAWINGS FOR FULL EXTENT OF SIDEWALK AND PAVING REMOVAL. <br />D4 REMOVE (E) CONCRETE STEPS AND METAL RAILING, <br />D5 REMOVE (E) WINDOWS AND CONCRETE WALL TO EXTENTS SHOWN. REMOVE INTERIOR <br />INSULATION AND GYP BOARD ONLY TO SAME EXTENTS AS WALL REMOVAL OR AS REQUIRED <br />FOR STRUCTURAL RETROFIT. CONCRETE TO BE SAWCUT FOR SMOOTH, EVEN EDGE, REFER <br />I TO DEMO ELEVATIONS D2.01 FOR ADDITIONAL INFORMATION. <br />D6 REMOVE (E) WINDOW. PRESERVE AND PROTECT OPENING FOR NEW WINDOW <br />REPLACEMENT. <br />246 D7 REMOVE (E) DOOR AND FRAME. <br />D8 REMOVE (E) CONC FILLED METAL PAN STAIR, LANDING, GUARD AND HANDRAILS. <br />D10 REMOVE (E) CABINETS AND/OR COUNTEROP, <br />D11 REMOVE (E) INTERIOR WALL AS INDICATED. <br />D12 REMOVE (E) INTERIOR DOOR AND FRAME. <br />D13 REMOVE (E) GYP; PLASTER FINISH TO EXPOSE WOOD COLUMN, TYP. USE CAUTION TO AVOID <br />DAMAGE TO COLUMN SURFACE AND STRUCTURAL INTEGRITY DURING DEMO. <br />D14 REMOVE (E) VINYL FLOORING AND RUBBER BASE. SCRAPE ADHESIVE AS REQUIRED AND <br />PREP FOR NEW FLOOR FINISH. <br />D15 REMOVE (E) CARPET OR CARPET TILE, PADDING, AND RUBBER BASE. SCRAPE ADHESIVE AS <br />REQUIRED AND PREP FOR NEW FLOOR FINISH. <br />D16 REMOVE (E) ACOUSTIC TILE CEILING, GRID, AND SUPPORT. REMOVE ALL CEILING MOUNTED <br />p2 LIGHT FIXTURES AND HVAC REGISTERS. SEE ELECTRICAL AND MECHANICAL FOR <br />ADDITIONAL INFORMATION, SEE FIRE PROTECTION DRAWINGS FOR SPRINKLER SYSTEM <br />3 REMOVAL. <br />D17 REMOVE (E) TOILET PARTITIONS. FILL HOLES AND PATCH AND/OR LEVEL CONCRETE AS <br />REQUIRED FOR SMOOTH, LEVEL SURFACE. <br />D18 REMOVE (E) RESTROOM ACCESSORIES INCLUDING BUT NOT LIMITED TO MIRRORS; GRAB <br />i BARS, PAPER TOWEL, TOILET PAPER, SOAP, AND FEMININE HYGEINE DISPENSERS; AND <br />WASTE RECEPTACLES. <br />D19 REMOVE (E) PLUMBING FIXTURE(S) AS SHOWN, SUPPLY AND DRAIN PIPING TO BE REMOVED <br />D7 AND FILLED OR CAPPED AS DIRECTED IN PLUMBING DRAWINGS. <br />— — —'� ID8 D20 REMOVE (E) PLUMBING PIPING AND FITTINGS, SALVAGE FOR RECYCLING OR PROPERLY <br />DISPOSE OF. SEE PLUMBING DEMO DRAWINGS, <br />D21 <br />REMOVE (E) CONC PAD WHERE MECH/ELEC EQUIP HAS BEEN REMOVED, PATCH ANDIOR <br />GRIND CONCRETE SMOOTH AND LEVELAND PREP FOR NEW FINISH AS REQUIRED. <br />D22 <br />REMOVE (E) STAIR, LANDINGS, HAND AND GUARD RAILS, AND FRAMING IN THEIR ENTIRETY. <br />D23 <br />REMOVE (E) HYDRAULIC ELEVATOR, STRUCTURE, AND MACHINERY, PROVIDE TEMPORARY <br />STRUCTURAL SUPPORT AS REQUIRED. REFER TO STRUCTURAL DRAWINGS FOR NEW <br />FRAMING THIS AREA. <br />D24 <br />REMOVE ALL DATA AND COMMUNICATION WIRING, EQUIPMENT, SUPPORT BRACKETS, AND <br />PLYWOOD BACKBOARDS, TYP, WIRING AND EQUIPMENT TO BE SALVAGED AND RECYCLED <br />OR PROPERLY DISPOSED OF, <br />D6 D25 <br />REMOVE (E) CONCRETE SLAB OR FLOOR STRUCTURE FOR NEW ELEVATOR PIT AND SHAFT. <br />I <br />TYP <br />SEE SLAB PLAN SHEET A2.01s FOR DIMENSIONS. <br />D26 <br />REMOVE (E) MOP SINK, WATER HEATER, AND CONCRETE PAD, <br />D36 <br />REMOVE (E) ACOUSTIC CEILING TILES, CEILING GRID AND SUPPORT TO REMAIN AND BE <br />REPAINTED. <br />D37 <br />REMOVE (E) WOOD HANDRAILS AND BRACKETS. PATCH WALL SURFACE AS REQUIRED FOR <br />I <br />SMOOTH CONSISTENT FINISH, <br />D39 <br />SAWCUT AND REMOVE (E) CONCRETE FOR NEW WINDOW OPENING, REFERENCE DEMO <br />ELEVATIONS D2.01 AND A3 SHEETS FOR EXTERIOR ELEVATIONS. <br />D50 <br />REMOVE AND RELOCATE EXISTING ROOF DRAIN PER PLUMBING DRAWINGS. <br />s°� r Ms 9 <br />I 0$, _a <br />R <br />a <br />808 <br />% <br />1 <br />STAMP <br />p5& Inc. <br />Ste B0 <br />- 972011 <br />7.5825 <br />TT <br />G <br />CONSULTANT <br />TITLE <br /># DATE DESCRIPTION <br />REVISIONS <br />KE, MS WY, JG <br />DRAWN BY CHECK BY <br />100% ISSUE SET/BID SET <br />STATUS <br />04/17/2020 <br />DATE <br />328801 <br />PROJECT NUMBER <br />D1.01 a <br />@ 2020 OTAK, INC. <br />If this drawing is not 24" x 36", it has been <br />reducedlenlarged. Scale accordingly. <br />