I
<br />I
<br />SEE 101 01 a
<br />m
<br />MATCHLINE I r
<br />I
<br />D5 I
<br />I
<br />I o
<br />; r
<br />I �
<br />ti•
<br />I
<br />�
<br />I
<br />L
<br />i
<br />D6 I
<br />E1 D1 C1 B2 131
<br />jj
<br />L /
<br />:.
<br />l - _T _T glll-
<br />' lll�� 101 f !! II II D24
<br />l J1 LI1 Ll Illj ui Uj � �I OFFICE l) 4 D24 I�
<br />II 1 I III \ ll I I CI — — — — 'I j SPRINKLER RISER
<br />lIL ` MEN'S Ill WOMEN'S Jll D15 II
<br />D14 D18 D14 D18 D12 Q15 (l D2.01 IT/DATA ( — —
<br />1 l I I l D28
<br />O D17 D19 D17 D19 ll I _
<br />l D35 Ill D35 — -I I D11 L — —
<br />Il I � I � I � ► —_=—_
<br />ILQ D11
<br />mil- _ _ I II OFFICE (( _ VESTIBULE
<br />( l D15 D11 D15
<br />JANITOR. - ll D12 '{ D16
<br />D12
<br />D12 D19 D12 D11 D12 7
<br />In I I I D33 I D11
<br />I i._ _ F
<br />JI
<br />I ll II IT STORAGE ll
<br />OFFICE
<br />6ICE
<br />D15 D15 IIlI
<br />D11
<br />OFFICE D16
<br />D15 D11
<br />D1I Ill I II I I
<br />D6-
<br />I
<br />ll I { D11
<br />I I ( D13
<br />I I TYP.
<br />(
<br />I
<br />_< D5 I li l I I I
<br />D13 I
<br />— — TYP.
<br />I
<br />D11
<br />wai
<br />OPEN OFFICE
<br />D15
<br />D16
<br />D13 I
<br />TYP.
<br />:LIMITED SCOPE THIS AREA FOR
<br />TRUCTURAL RETROFIT AS INDICA-
<br />IRM
<br />D) (C
<br />I
<br />B
<br />DEMOLITION NOTES
<br />1. DASHED LINES INDICATE OBJECTS TO BE DEMOLISHED AND / OR SALVAGED.
<br />2. ITEMS SALVAGED FOR RE -USE SHALL BE SAFELY STORED AND PROTECTED FROM DAMAGE DURING
<br />CONSTRUCTION.
<br />3. EXISTING FURNITURE, DECORATIVE LIGHTING, & EQUIPMENT NOT TO BE RE -USED. CONTRACTOR TO
<br />BE RESPONSIBLE FOR SALVAGING FOR RECYCLING OR DISPOSAL AS REQUIRED.
<br />4, REFER TO THE REFLECTED CEILING PLANS FOR ADDITIONAL DEMO NOTES SPECIFIC TO THE EXISTING
<br />A AA CEILING CONDITIONS.
<br />5. CONTRACTOR IS RESPONSIBLE FOR THE SAFE REMOVAL OF ANY AND ALL MATERIALS REFERRED TO
<br />IN THE MED-TOX 2007 HAZARDOUS BUILDING MATERIALS SURVEY. SHOULD THE CONTRACTOR
<br />ENCOUNTER ANY ADDITIONAL ASBESTOS MATERIALS, PCB'S, OR OTHER TOXIC SUBSTANCES NOT
<br />NOTED IN THE SURVEY, THE CONTRACTOR SHOULD IMMEDIATELY REPORT THE FINDINGS IN WRITING
<br />TO THE BUILDING OWNER & TENANT, PRIOR TO CONTINUING WITH ANY WORK IN THE AREA. WORK
<br />EE 1/D 1.01 a HALL NOT BE RESUMED EXCEPT
<br />S S 0 C T BY WRITTEN AUTHORIZATION OR AGREEMENT FROM THE OWNER.
<br />F.
<br />x
<br />6 EXISTING HVAC EQUIPMENT, PLUMBING, DRAIN & FIRE PROTECTION LINES TO BE DEMOLISHED
<br />MATCHLINE
<br />Ili I EXCEPT AS NOTED. REFER TO MECHANICAL AND PLUMBING DEMOLITION DRAWINGS FOR FULL
<br />EXTENT OF DEMO. CONTRACTOR SHALL VERIFY EXISTING ITEMS TO REMAIN WITH
<br />4 ARCHITECT/MECHANICAL DESIGNER, COORDINATE WITH PROPERTY PRIOR TO INTERFERING WITH
<br />EXISTING FIRE SPRI KLER EXISTING UTILITIES.
<br />RISER TO REMAIN. S E FIRE
<br />PROTECTION/PLUMOING 7, THE PLANS/ELEVATIONS ARE DERIVED FROM ARCHIVAL BUILDING PLANS &ARE INTENDED TO
<br />-} DRAWINGS FOR NE REASONABLY REPRESENT EXISTING CONDITIONS. ACTUAL CONDITIONS MAY DEVIATE FROM THAT
<br />- 1 ' SHOWN ON THE DRAWINGS. THE DEMO NOTES IDENTIFY SPECIFIC AREAS OF WORK, BUT MAY NOT BE
<br />SPRINKLER SYSTEM COMPLETE IN THE IDENTIFICATION OF ALL REMOVALS. THE CONTRACTOR SHALL VERIFY ACTUAL
<br />CONDITIONS & COORDINATE DEMO WITH NEW WORK SO THAT DEMO IS COMPLETE.
<br />D37 — - I 8. EXISTING LIGHT FIXTURES AND ELECTRICAL COMPONENTS TO BE REMOVED EXCEPT AS NOTED,
<br />17 REFER TO ELECTRICAL DEMOLITION PLANS FOR FULL EXTENT OF DEMOLITION AND FIXTURES BEING
<br />STAIR D2 REMOVED.
<br />D15 j ``, 9. EXISTING FINISHES WILL BE REMOVED IN THEIR ENTIRETY WHERE INDICATED AND EXPOSED
<br />SURFACES PREPARED FOR NEW FINISHES.
<br />— — -� — ---2 10. ALL WORK WHICH IS TO REMAIN SHALL BE PROTECTED FROM DAMAGE AND, IF DAMAGED, SHALL BE
<br />_ REPAIRED AT NO COST TO THE OWNER. PROVIDE DUST ISOLATION & PROTECTION TO LIMIT DUST TO
<br />— D8 AREAS OF WORK.
<br />D5 I
<br />0
<br />G
<br />KEYNOTE LEGEND
<br />— — — — 4
<br />D6 D2 REMOVE (E) STEEL CANOPY POSTS, FRAMING, ROOF STRUCTURE, AND FOOTINGS. PROTECT
<br />i EXISTING EXPOSED AGGREGATE CONCRETE TO REMAIN FROM DAMAGE DURING
<br />I DEMOLITION.
<br />D5 REMOVE (E) WINDOWS AND CONCRETE WALL TO EXTENTS SHOWN. REMOVE INTERIOR
<br />INSULATION AND GYP BOARD ONLY TO SAME EXTENTS AS WALL REMOVAL OR AS REQUIRED
<br />D5 FOR STRUCTURAL RETROFIT. CONCRETE TO BE SAWCUT FOR SMOOTH, EVEN EDGE. REFER
<br />TO DEMO ELEVATIONS D2.01 FOR ADDITIONAL INFORMATION.
<br />D6 REMOVE (E) WINDOW. PRESERVE AND PROTECT OPENING FOR NEW WINDOW REPLACEMENT.
<br />I D7 REMOVE (E) DOOR AND FRAME.
<br />o D8 REMOVE (E) CONC FILLED METAL PAN STAIR, LANDING, GUARD AND HANDRAILS.
<br />00 D11 REMOVE (E) INTERIOR WALL AS INDICATED,
<br />D12 REMOVE (E) INTERIOR DOOR AND FRAME,
<br />D13 REMOVE (E) GYP/PLASTER FINISH TO EXPOSE WOOD COLUMN, TYP. USE CAUTION TO AVOID
<br />DAMAGE TO COLUMN SURFACE AND STRUCTURAL INTEGRITY DURING DEMO,
<br />D14 REMOVE (E) VINYL FLOORING AND RUBBER BASE, SCRAPE ADHESIVE AS REQUIRED AND
<br />PREP FOR NEW FLOOR FINISH.
<br />D15 REMOVE (E) CARPET OR CARPET TILE, PADDING, AND RUBBER BASE, SCRAPE ADHESIVE AS
<br />REQUIRED AND PREP FOR NEW FLOOR FINISH,
<br />D16 REMOVE (E) ACOUSTIC TILE CEILING, GRID, AND SUPPORT, REMOVE ALL CEILING MOUNTED
<br />LIGHT FIXTURES AND HVAC REGISTERS, SEE ELECTRICAL AND MECHANICAL FOR ADDITIONAL
<br />INFORMATION. SEE FIRE PROTECTION DRAWINGS FOR SPRINKLER SYSTEM REMOVAL.
<br />r D17 REMOVE (E) TOILET PARTITIONS. FILL HOLES AND PATCH AND/OR LEVEL CONCRETE AS
<br />REQUIRED FOR SMOOTH, LEVEL SURFACE.
<br />D18 REMOVE (E) RESTROOM ACCESSORIES INCLUDING BUT NOT LIMITED TO MIRRORS; GRAB
<br />BARS, PAPER TOWEL, TOILET PAPER, SOAP, AND FEMININE HYGEINE DISPENSERS; AND
<br />WASTE RECEPTACLES,
<br />D12 D11 D19 REMOVE (E) PLUMBING FIXTURE(S) AS SHOWN. SUPPLY AND DRAIN PIPING TO BE REMOVED
<br />AND FILLED OR CAPPED AS DIRECTED IN PLUMBING DRAWINGS.
<br />CITY OF EVERETT
<br />REVIEWED FOR PERM11'
<br />01
<br />LEVEL 01-A
<br />r r,
<br />f
<br />%LEVEL 01 B ;
<br />-29
<br />It
<br />STAMP
<br />CONSULTANT
<br />M
<br />0
<br />0
<br />z
<br />W
<br />Q
<br />Q
<br />O O
<br />00
<br />0 z <
<br />ZU)
<br />vry
<br />Q � W
<br />�./ 04 W
<br />TITLE
<br /># DATE DESCRIE
<br />m
<br />I
<br />TION
<br />REVISIONS
<br />KE, MS WY, JG
<br />DRAWN BY CHECK BY
<br />100% ISSUE SET/BID SET
<br />STATUS
<br />04/17/2020
<br />DATE
<br />328801
<br />PROJECT NUMBER
<br />D1
<br />0l b
<br />■
<br />2020OTAK, INC,
<br />If this drawing is not 24"x 36", it has been
<br />reducedfenlarged. Scale accordingly.
<br />SCALE, 1/8" = V-0"
<br />
|