Laserfiche WebLink
Bedroom Kitchen <br />Occupants: 2 Occupants: <br />(Actual Bets) (156 SF/200) <br />T <br />Lounge <br />Occupants: 2 <br />(383 SF/200) <br />®T <br />Elevator <br />Occupants:16 <br />(Actual Beds) <br />Occupants:1 <br />(f SF/200) Hallway <br />Exam <br />Occupants:1 <br />(98 SF/100) <br />Office <br />Occupants: 2 <br />(169 SF/100) <br />wo <br />r r. <br />I I I <br />J L L <br />TI I IT IT <br />L J_J J <br />T T IT <br />J L L <br />,a tv <br />s: 40 <br />11 S) <br />Fr 71 <br />I <br />Tr I tT T <br />� <br />TIIIT IT <br />� r r <br />I I I <br />J L L <br />® <br />1 1 <br />Stairway <br />77� <br />Down to <br />1 <br />Longest Travel Distance:149' <br />`Exit <br />at Grade <br />(52 SF/200) MW Iwo MW Eno <br />000000 <br />VJanitor F-- <br />Laund <br />cupan :1 <br />(41 SF/2 <br />To Floor 0%c:c%,u anc;v,& ExifinqPlan <br />P <br />Scale: 1/8" =1'-0" <br />Existing north stairway runs down to the exisitng main entrance lobby with direct outside access. Existing south stairway runs down to an existing at -grade exit. <br />Room Finish Schedule <br />ROOM NAME <br />FLOOR <br />BASE <br />WALLS <br />CEILING <br />REMARKS <br />BEDROOM <br />CARPET TILE <br />4" RUBBER <br />PAINTED GWB <br />PAINTED GWB <br />FLAT FIN15W <br />KITCHEN <br />SHEET VINYL <br />4" RUBBER <br />PAINTED GWB <br />PAINTED GWB <br />EGGSHELL FINISH <br />LOUNGE <br />CARPET TILE <br />WOOD <br />WOOD/GWB <br />2x2 ACT <br />TEXTURED CEILING TILES <br />6ENESI5 DORM <br />CARPET TILE <br />4" RUBBER <br />PAINTED GWB <br />PAINTED GWB <br />FLAT FIN/SN <br />GENESIS CLA56 <br />CARPET TILE <br />WOOD <br />WOOD/GWB <br />2x2 ACT <br />TEXTURED CEILING TILES <br />STORAGE <br />SHEET VINYL <br />4" RUBBER <br />PAINTED GWB <br />PAINTED GWB <br />EGGSNELL FINISH <br />HALLWAY <br />VINYL PLANK <br />4" RUBBER <br />PAINTED GWB <br />2x4 ACT <br />MATCH EXISTING CEILING TILES <br />LINE DORM <br />CARPET TILE <br />4" RUBBER <br />PAINTED GWB <br />PAINTED GWB <br />FLAT FINISH <br />RESPITE CARE <br />CARPET TILE <br />4" RUBBER <br />PAINTED GWB <br />PAINTED GWB <br />FLAT FINISH <br />EXAM <br />SHEET VINYL <br />4" RUBBER <br />PAINTED GWB <br />2x4 ACT <br />MATCH HALLWAY CEILING TILES <br />JANITOR <br />514EET VINYL <br />VINYL COVE <br />GWB/FRP <br />PAINTED GWB <br />EG6514ELL FINISH <br />LAUNDRY <br />SHEET VINYL <br />VINYL COVE <br />PAINTED GWB <br />2x4 ACT <br />MATCH HALLWAY CEILING TILES <br />OFFICE <br />CARPET TILE <br />4" RUBBER <br />WOOD(SWB <br />2x4 ACT <br />MATCH HALLWAY CEILING TILES <br />T <br />North <br />Building Code Summary <br />Drawing Index <br />Code reference: 2015 IEBC, IBC, IFC, IMC, UPC, ANSI 117.1, WSEC <br />Architectural Structural <br />Occupancy (IBC Section 310.4): R-2 (congregate living facility, nontransient) <br />A1.00 Cover Sheet SI A General Notes <br />Construction type (IBC Section 602.5): Type VA (new & existing) <br />A1.01 Code Summary, Site Plan, Schedules Electrical <br />Sprinkler system throughout: Yes <br />A1.02 Top Floor Plan, Details E0.00 Cover Sheet <br />IEBC compliance Section 301.1.2; Section 504, Level 2 alteration <br />A1.03 Top Floor Reflected Ceiling Plan E2.03 Top Floor Lighting Plan <br />Building area: 4,955 SF Basement (existing/unchanged) <br />A1.04 Interior Elevations E3.03 Top Floor Power Plan <br />7,194 SF Main Floor (existing/unchanged) <br />General <br />Notes E4.00 Electrical Panel Schedules <br />5,460 SF Top Floor (existing/unchanged) <br />17,629 SF Total (existing/unchanged) <br />1. The project described herein is intended to be constructed in compliance with all applicable <br />codes and/or as otherwise approved by the governing jurisdictions, even though every detail <br />Code Notes: <br />of such compliance is not shown nor described herein. The Architect shall be notified for <br />1. Original building approved by the City of Everett ca.1992 as "Type V One Hour Fully Sprinklered" <br />clarification or additional information as needed to construct the project as intended or <br />reasonably inferenced from the drawings, specifications, discussions, or other information. <br />2. Building areas based on approved original building drawings. Verify as required. No increase <br />in building area is sought for the proposed scope of work. <br />2. The Contractor shall notify the Architect if the existing conditions are not as shown on the <br />drawings or otherwise not suitable to accomodate the proposed work. <br />3. The proposed improvements are limited to 4,506 gross SF of the top floor. No work is <br />3. The Architect shall be the primary means of communication to each consultant. Any <br />proposed at the basement or main floor levels, or to the exterior of the building. <br />deviations from the project drawings, specifications, or other directions shall be coordinated <br />4. Verify compliance with applicable portions of the 2015 IBC, 2015 IEBC, 2015 IFC, 2015 IMC, 2015 <br />with the Architect prior to construction. <br />UPC, WSEC, and ICC/ANSI A117.1-2009 Accessible and Usable Buildings and Facilities, <br />4. The Contractor shall maintain the use by the Owner of the building areas not included in the <br />including Washington State amendments, as adopted by the City of Everett. <br />scope of work. <br />Occupancy & Exiting Notes <br />5. No site work, no new floor area, nor expansion of the building beyond the existing footprint is <br />sought in this application. <br />Top floor occupant load: 76 <br />6. The existing building is currently served by the local water, sewer, electric, and gas utilities. <br />Exits required: 2 <br />No changes are sought to any existing utility connections. <br />Exits provided: 2 <br />7. The proposed worts is to reconfigure certain spaces of the top floor of the existing shelter <br />building. Total overnight resident capacity is reduced from 83 to 66. No change in use, <br />Exit door width required (.2"/person): 72" (2 @ minimum required size) <br />occupancy, or operating times is proposed or sought with this permit application. <br />Exit door width provided: 108" (existing exit doors) <br />Exit <br />Electrical Notes <br />stair width required (.3"/person): 88" (2 @ minimum required size) <br />Exit stair width provided: 90" (existing exit stairs) <br />1. Any additional documentation required to demonstrate compliance with the Washington State <br />Maximum travel distance allowed: 250' <br />Energy Code and secure necessary permits, including but not limited to manual lighting <br />Maximum travel distance provided (longest is from Line Dorm): 149' <br />controls, lighting reduction controls, occupancy sensors, and emergency egress lighting, may <br />be amended or provided by the chosen design/build electrical contractor. Coordinate the <br />Existing exits provide access to accessible means of egress to the public way (see site plan), <br />installation of all work depicted in such documentation with that shown on the architectural <br />No changes proposed or required to the means of egress for the main floor and basement. <br />drawings. <br />2. The design/build electrical contractor shall verify and otherwise demonstrate the provision of <br />emergency egress lighting of 1 FC at the floor level along the means of egress path of travel. <br />Such emergency lighting may be provided by suitable bug -eye fixtures, hardwired to the <br />building's power supply and with a battery back-up. See electrical plans for suggested locations. <br />Mechanical Notes <br />1. The chosen design/build mechanical contractor shall provide any additional documentation <br />required to demonstrate compliance with the 2015 IEBC, 2015 IBC, 2015 IMC, and the <br />Washington State Energy Code and secure necessary permits. No modifications to the <br />existing HVAC system serving the existing floor area is proposed, except for relocation of <br />existing grilles and/or diffusers. Verify the existing HVAC equipment provides 5 CFM outdoor <br />air, and 15 CFM ventilation air. <br />Site <br />Deferred Submittals <br />E <br />co <br />38th St. <br />Map <br />No Scale <br />Site Address: 3711 Smith Avenue, Everett, WA 98201 <br />Door Schedule <br />NOMINAL SIZE <br />DOOR <br />FRAME <br />zuzl <br />z� <br />HARDWARE <br />REMARKS <br />3070A <br />3'-0" x 7'-0" <br />SOLID CORE WOOD VENEER + GLASS <br />NM <br />NA. <br />LEVER <br />VISION PANEL, SELF -CLOSING, 20 MIN. RATING, SMOKE $ DRAFT CONTROL PER 13C 7163.3 <br />30108 <br />3'-0" X 7'-0" <br />SOLID CORE WOOD VENEER <br />HM <br />NA. <br />LEVER <br />SELF -CLOSING, 20 MIN. RATING, SMOKE $ DRAFT CONTROL PER IBC 7163.3 <br />3070C <br />3'-0" X 7'-0" <br />WOOD + GLASS <br />WM <br />NA. <br />LEVER <br />GLASS PANELS, SELF -CLOSING, MATCNING FIXED SIDELIGHT, 20 MIN RATING, SMOKE t DRAFT CONTROL PER BC 7163.3 <br />3fi70A <br />Y-6"x 7'-0" <br />NA. <br />WM <br />NA. <br />NA. <br />HOLLOW METAL FRAME ONLY, NO INTEGRAL STOP AT JAMB $ HEAD <br />5070A <br />5'-0" x 7'-0" <br />NA. <br />PM <br />NA. <br />NA. <br />HOLLOW METAL FRAME ONLY, NO INTEGRAL STOP AT JAMB $ HEAD <br />fi070A <br />0 3'-O" x 7'-0" <br />SOLID CORE WOOD VENEER + GLASS <br />WM <br />NA. <br />LEVER <br />VISION PANEL, SELF -CLOSING, 20 MIN. RATING, SMOKE $ DRAFT CONTROL PER IBC 7163.3 <br />SEE FLOOR PLAN FOR ACTUAL DOOR SWING, JAMB THICKNESSES, AND OUANTITIES. VERIFY KEYING WITW OWNER HARDWARE AND OPERATION SHALL COMPLY WITH IBC SECTION 1010.1.9J AND ICC A117.1-2009, CHAPTER 4042. <br />3'-0" 3'-0" 3'-0" 3'-0" 6'_p,►" <br />oe NOMINAL NOMINAL NOMINAL 8" x ' RATED GLASS NOMINAL 00 NOMINAL <br />5„ RAILS � <br />8" x 33"RATED GLASS <br />� NO STOP ON � <br />6„ ,w� FIXED SIDELIGHT JAMBS, TYP. <br />_� / _9 _� <br />v' --I %5"STILE N 0 U) 0 a' <br />Z _ Z RATED GLASS PANELS <br />a <br />8" STILE W/KICK PLATE z z z <br />0 <br />3070A KICK PLATE 30706 KICK PLATE 3070C 6070A KICK PLATE 3670A <br />rziw/ou <br />5070A <br />NO STOP ON <br />JAMBS, TYP. <br />PO BOX 141 <br />1DM0N0S, WASHING10N 98f <br />�206j 920.3554 P <br />WWW.PWFARCHITECIURE.COM <br />i•. i Mwdmrofthe <br />American Institute of Architects <br />PROJECT NAME: <br />Everett Gospel Mission <br />Men's Shelter Remodel <br />3711 Smith Avenue <br />Everett, WA 98201 <br />PROJECT NUMBER: <br />01.15013 <br />DATE: <br />February 1, 2019 <br />STAMP: <br />REGISTERED <br />ARCHITECT <br />W. <br />wASHI GTON <br />NOTE: <br />The information contained herein is intended to <br />be used in conjunc tim with shop drawings, <br />approved submittals, diagrams, specifications, <br />and any other documents as required as a guide <br />for construction in a manner consistent with <br />applicable codes and generally -accepted <br />industry standards of construction. Any conflicts <br />within and between these documents and such <br />codes and standards shall be brought to the <br />attention of the Architect prior to construction for <br />dariflation as needed. <br />tEVISIONS: <br />04/22/19 <br />SHEET ililE: <br />Code Notes, Site Plan, <br />Schedules <br />SNEEI NUMBER: <br />41. 1 <br />