• • <br /> 3. The door into the officeon the lower floor should be shown with a minimum of 18"clear <br /> to the adjacent wall from the pull side. ANSI Section 404.2.3 <br /> 4. The turning space should be shown for the new women's restroom. ANSI Section 603.2.1 <br /> 5. The clear floor space for the sink should be shown in the new men's restroom. ANSI <br /> Section 606.2 <br /> 6. Handrails, handrail extensions and edge protection should be shown for the new ramp on <br /> the lower floor. IBC Section 1012.8 & 1012.10 <br /> STRUCTURAL <br /> 1. The design live loads for the increased occupant load of the assembly areas on the upper <br /> floor should be provided. Calculations should be provided to substantiate the increased <br /> loading. IEBC Section 506.4 <br /> 2. The plans refer to the IRC for details of construction for the covered deck and stairs. The <br /> deck addition should have the design for the lateral force resisting system shown on the <br /> plans with corresponding details and calculations provided in compliance with the IBC. <br /> IBC Section 101.2 <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two new sets of revised construction documents reflecting the corrections <br /> requested. Please include a response letter which indicates how the corrections were resolved. <br /> All codes cited refer to the 2018 International Building Code (IBC), 2018 International Existing <br /> Building Code (IEBC), the 2018 International Fire Code (IFC), the 2018 International Mechanical <br /> Code (IMC), and/or the 2018 Washington State Energy Code (WSEC), as amended by the State <br /> of Washington and adopted by the City of Everett. The current IBC referenced standard for <br /> accessible design is the 2009 "Accessible and Usable Buildings and Facilities" (ICC/ANSI <br /> A117.1). Federal ADA regulations and standards may be more restrictive. <br /> These comments address building issues only. Additional revisions or additions may be required <br /> by other departments (such as Utilities, Traffic, Planning or Fire). All required submittals must <br /> be of sufficient detail and information to ensure that the proposed structure will be constructed <br /> in compliance with all adopted codes. <br /> Sincerely, <br /> Tony Lee <br /> Building Official <br /> � i� <br /> O 3200 Cedar Street © 425.257.8810 O tlee@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov <br />