• • <br /> that accessible improvements are not limited to providing van accessible spaces. Other <br /> accessible spaces shall be improved to meet current requirements, or other inaccessible <br /> features shall be improved, as required by IEBC Section 705.2. Improvements may <br /> include, but are not limited to, restriping of other accessible spaces and adding signage. <br /> The existing van accessible space is within the building footprint on the first level <br /> and meets the current dimensions for van parking. Building clear height is 7'-0"and <br /> is posted on an existing overhead limit pole at the entrances. ADA and Van parking <br /> stall striping on the fourth floor have been dimensioned on the revised plans A1.11 <br /> and A 1.12. These dimensions replace the detail E4/A1.11. <br /> 4. Sheet A1.11 shows new accessible spaces on both sides of the elevator core. See IBC <br /> Section 1101.2The following comments shall be addressed: <br /> a. The boundary of the spaces immediately adjacent to the core is not defined. <br /> Striping consistent with Detail E4/A1.11 shall be shown to confirm that the required <br /> minimum dimensions are provided. See 107.2.1. <br /> Existing ADA stall layout meets or exceeds the minimum required <br /> dimensions shown on Detail E4/A1.11. <br /> b. The minimum accessible clearance shall be provide between the elevator entrance <br /> and the adjacent parking space. See ICC A117.1-09 Section 304 and Chapter 4. <br /> Existing parking layout exceeds the 60"minimum clearance required. <br /> c. The locations of the van-accessible spaces shall be specified on the plans. <br /> See response to comment#3 above. <br /> This comment has not been completely addressed. Sheet A1.11 shows new accessible <br /> spaces on both sides of the elevator core. See IBC Section 1101.2 and Comment 3 above <br /> for additional information The following comments shall be addressed: <br /> a. The boundary of the spaces immediately adjacent to the core is not defined. <br /> Striping consistent with Detail E4/A1.11 shall be shown to confirm that the required <br /> minimum dimensions are provided. See 107.2.1. <br /> Boundary lines are shown for the parking stalls adjacent to the elevator on <br /> the revised plans. <br /> b. No additional comment. <br /> c. The locations of the van-accessible spaces shall be specified on the plans. See <br /> revised plan for dimensions on van accessible and ADA stalls and the <br /> addition of a "VAN ACCESSIBLE" sign, mounted on the wall below the <br /> existing ADA sign as noted on the plan and new detail A2/A1.13. <br /> 5. Detail E4/A1.11 specifies the access aisle on the driver-side of the van-accessible parking <br /> space. The aisle shall be located on the passenger-side for angled parking spaces. See <br /> IBC Section 1101.2 and ICC A117.1-09 Section 502.4.1. <br /> This comment has not been addressed. The original comment stated that Detail E4/A1.11 <br /> specifies the access aisle on the driver-side of the van-accessible parking space instead <br /> of the passenger-side as required for angled parking spaces. The detail has been revised <br /> to eliminate the van-accessible space. However, striping for van-accessible spaces is <br /> required per Comment 3 above. The detail shall be revised as stated in the original <br /> comment. See IBC Section 1101.2 and ICC A117.1-09 Section 502.4.1. <br /> � I � <br />