Laserfiche WebLink
2/15/2022 Page <br /> City of Everett 2 I 3 <br /> 6:40:50AM <br /> INSPECTION ACTIVITY REPORT <br /> 1/18/2022 1/18/2022 ELEC 09-FINAL TJJO CORRECTION eTRAKiT Inspection 1/17/2022 6:45 PM ENERGY FLOW <br /> Request ELECTRIC INC <br /> lock box code 4016 same for garage <br /> Contact Name:ENERGY FLOW <br /> ELECTRIC INC <br /> Site Address: 1219 MAPLE ST <br /> Phone:4257374221 <br /> e-Mail:energyflowelectric@gmail.com <br /> (1/18/2022 2:54 PM TJJO) <br /> -All grounding electrode conductors must <br /> land on the grounded bus 250.24(4) <br /> -in looking at sub panel no equipment <br /> grounding conductor is running with <br /> overhead service,please provide in in <br /> accordance with 250.122 <br /> -Panel needs labeling in accordance with <br /> 230.85 <br /> -check lights for bushings or gromets <br /> 1/25/2022 1/26/2022 ELEC 09-FINAL SKB CANCELLED eTRAKiT Inspection 1/24/2022 9:54 AM Seyi Oluwole <br /> Request Added DFCI to existing wiring from <br /> 08/30/2015(Date)16:04:18(Time) <br /> Does the city want me to put a new <br /> sub-panel in the garage;the current <br /> subpanel in the garage was permitted as <br /> part of Permit No:01898? <br /> Note the following; <br /> corrections keep changing on existing <br /> things. <br /> No electrical work has been done either by <br /> me or anybody since at least 08/30/2015 <br /> (Date)16:04:18(Time) <br /> The work done by my ELECTRICIAN has <br /> nothing to do with the garage before. <br /> NOW ALL THE CORRECTIONS ARE IN <br /> THE GARAGE <br /> Contact Name:Seyi Oluwole <br /> Site Address:1219 MAPLE ST <br /> Phone:2063709445 <br /> e-Mail:jwheelsamericallc@outlook.com <br /> (1/26/2022 6:25 AM SKB) <br /> Cancelled per owner. <br /> 2/1/2022 2/1/2022 ELEC 09-FINAL TJJO CORRECTION eTRAKiT Inspection 1/28/2022 8:18 AM Seyi Oluwole <br /> Request Ref:City of Everett Electric Wiring Permit <br /> No:01898 <br /> Issued on 7/7/83 approved on 7/13/83;note <br /> on the approval inspection report call PUD <br /> at 258-8255 for service connection. <br /> All the corrections in the garage need to be <br /> grandfathered in as existing. <br /> Note that GFCI circuits were added along <br /> with several corrections that were not part <br /> of the intent of the permit I applied for <br /> through my electrician. <br /> Contact Name:Seyi Oluwole <br /> Site Address: 1219 MAPLE ST <br /> Phone:2063709445 <br /> e-Mail:jwheelsamericallc@outlook.com <br /> (2/1/2022 9:29 AM TJJO) <br /> Corrections not completed <br /> 2/10/2022 2/10/2022 ELEC 08-OTHER TJJO CORRECTION (2/10/2022 12:34 PM TJJO) <br /> Kitchen recep being fed from bath needs to <br /> be corrected <br /> INSP12 CRWs YSTEMS <br />