ARCHITECTURAL SYMBOLS <br />TRUE PLAN <br />NORTH NORTH <br />NORTH ARROW <br />0 4 8 16 GRAPHIC SCALE <br />SCALE: 1/8" = V-0 <br />1 <br />4 A-211 2 INTERIOR ELEVATION <br />3 <br />SIM <br />1 DETAIL CALLOUT - SECTION <br />A-591 <br />rSIM <br />1 DETAIL CALLOUT - PLAN <br />A-591 <br />0- -- DOOR NUMBER CALLOUT <br />a <br />FLOOR FINISH TRANSITION <br />f-- <br />U <br />ROOM <br />NAME ROOM NAME/NUMBER <br />101 <br />CEILING HEIGHT <br />r - - CENTER LINE <br />6W1 WALL TYPE CALLOUT <br />FC1 FLOOR/CEILING TYPE CALLOUT <br />W1 WINDOW TYPE CALLOUT <br />RELITE TYPE CALLOUT <br />SHEET NOTE <br />Al REVISION <br />P R NC H. LITHCRETI <br />V DIIE 11 E EA, <br />1%10 <br />47*10 COLBY <br />JWA <br />EVERETT Px 98203 <br />It"'i'SUE FOR BID, PERMIT, AND CONSTRUCTIO <br />ABBREVIATIONS <br />AFF <br />ABOVE FINISHED FLOOR <br />NIC <br />NOT IN CONTRACT <br />CG <br />CORNER GUARD <br />OC <br />ON CENTER <br />DS <br />DOWNSPOUT <br />OFCI <br />OWNER FURNISHED, CONTRACTOR INSTALLED <br />EQ <br />EQUAL <br />OPP <br />OPPOSITE <br />FV <br />FIELD VERIFY <br />PPT <br />PRESSURE PRESERVATIVE TREATED <br />GA <br />GAUGE <br />SIM <br />SIMILAR <br />GWB <br />GYPSUM BOARD <br />TB <br />TACKBOARD <br />MAX <br />MAXIMUM <br />TYP <br />TYPICAL <br />MDF <br />MEDIUM DENSITY FIBERBOARD <br />UNO <br />UNLESS NOTED OTHERWISE <br />MIN <br />MINIMUM <br />WB <br />WHITEBOARD <br />VICINITY MAID <br />PLAN <br />NORTH <br />Additional Permits Are Required <br />For This Project To Include: <br />Plumbing Sprinkler <br />Mechanical Fire Alarm <br />Electrical <br />MONITORED AUTOMATIC FIRE <br />DETECTION SYSTEM REQUIRED <br />�jSUPERVISED AUTOMATIC <br />IL�J SPRINKLER SYSTEM REQUIRED <br />PROJECT GENERAL NOTES <br />1. ALL CONSTRUCTION SHALL COMPLY WITH THE 2017 INTERNATIONAL BUILDING CODE, <br />THE AMERICANS WITH DISABILITIES ACT, AND ALL APPLICABLE LOCAL CODES, <br />ORDINANCES, AND STANDARDS. <br />2. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. THE CONTRACTOR SHALL NOTIFY <br />ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. <br />3. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE <br />WORK, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF <br />QUESTIONS CANNOT BE RESOLVED IN THIS MANNER, CONTACT THE ARCHITECT <br />PRIOR TO PROCEEDING WITH THE WORK. <br />4. AN APPROVED PUBLIC SAFETY KEY BOX SHALL BE INSTALLED ADJACENT THE MAIN <br />ENTRANCE AND SHALL BE CLEARLY VISIBLE, MOUNTED WITHIN SIX FEET OF THE <br />GRADE, AND APPROVED BY THE LOCAL JURISDICTION. THE KEY BOX SHALL CONTAIN <br />KEYS THAT OPERATE THE ELEVATOR RECALL AND EMERGENCY OVERRIDE SYSTEMS. <br />KEYS SHALL BE CLEARLY MARKED AS FOR WHAT DOOR, ROOM, AREA OR LOCK THEY <br />SERVE. THE KEY BOX SHALL CONTAIN KEYS TO OPEN DOORS OR OTHER ACCESS <br />MEANS AT THE FOLLOWING LOCATIONS: <br />• THE MAIN ENTRANCE <br />• ROOMS CONTAINING CONTROL VALVES FOR AUTOMATIC SPRINKLER <br />SYSTEMS <br />• ROOMS CONTAINING FIRE ALARM SYSTEM CONTROL PANELS <br />• ROOMS CONTAINING ELEVATOR EQUIPMENT <br />• ROOMS CONTAINING MAIN ELECTRICAL SERVICES PANELS <br />5. WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERED TO IN SINGULAR IT IS <br />INTENDED THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICES, ITEMS OR PARTS <br />AS ARE REQUIRED TO PROPERLY COMPLETE THE WORK. <br />6. FIELD MEASURE AND CONFIRM DIMENSIONS FOR OWNER PROVIDED EQUIPMENT AND <br />FURNISHINGS. <br />7. PROVIDE STIFFENERS, BRACING, BACKING PLATES AND BLOCKING REQUIRED FOR <br />SECURE INSTALLATION OF GRAB BARS, DOORS AND DOOR HARDWARE INCLUDING <br />WALL -MOUNTED DOOR STOPS, HANDRAILS, WALL -MOUNTED SHELVES, <br />MISCELLANEOUS EQUIPMENT, AND SUSPENDED MECHANICAL AND ELECTRICAL <br />EQUIPMENT. <br />8. COORDINATE AND PROVIDE ALL BASE AND HOUSEKEEPING PADS FOR MECHANICAL, <br />PLUMBING AND ELECTRICAL EQUIPMENT. <br />9. LOCATE ACCESS DOORS IN ACCORDANCE WITH APPLICABLE CODES, SUBMIT <br />PROPOSED LOCATIONS TO THE ARCHITECT FOR REVIEW AND ACCEPTANCE PRIOR <br />TO INSTALLATION. <br />10,. FINISH FLOOR ELEVATIONS ARE TO TOP OF CONCRETE AND TOPPING SLAB UNLESS <br />OTHERWISE NOTED. <br />11. COORDINATE EXACT SIZE AND PLACEMENT OF EQUIPMENT BEING PROVIDED. <br />12. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE BUILDING <br />STRUCTURE AND STRUCTURAL COMPONENTS UNTIL FINAL CONNECTIONS HAVE <br />BEEN COMPLETED IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS. <br />13. FIRE BLOCKING AND SMOKE BARRIERS SHALL BE INSTALLED IN ACCORDANCE WITH <br />2017 INTERNATIONAL BUILDING CODE. <br />PROJECT TEAM <br />TENANT CONTRACTOR <br />PROVIDENCE ABSHER CONSTRUCTION <br />1820 14TH ST 1001 SHAW RD E <br />EVERETT, WA 98201 PUYALLUP, WA 98372 <br />CONTACT: DARREN REDICK CONTACT: KEARA FLYNN <br />PHONE: 425.258.7050 PHONE: 253.845.9544 <br />MECHANICAL & PLUMBING <br />SUNSET AIR <br />5210 LACEY BOULEVARD SE <br />LACEY, WA 98503 <br />CONTACT: RYAN PANTIER <br />PHONE: 360.456.4956 <br />ARCHITECT <br />BCRA, INC <br />414 STEWART ST, SUITE 200 <br />SEATTLE, WA 98101 <br />CONTACT: JANA SIMISON <br />PHONE: 253.627.4367 <br />ELECTRICAL FIRE PROTECTION ENGINEER <br />VALLEY ELECTRIC SHINN FIRE PROTECTION <br />1100 MERRILL CREEK PARKWAY 18802 80TH AVE, SOUTH <br />EVERETT, WA 98203 KENT, WA 98032 <br />CONTACT: ALEC DENSON CONTACT: ANDREW OLSON <br />PHONE: 425.772.1481 PHONE: 253.312.1113 <br />SHEET INDEX <br />SHEET <br />TITLE <br />01 - GENERAL <br />G-101 <br />COVER <br />G-102 <br />CODE INFORMATION <br />02 - ARCHITECTURAL <br />A-121 <br />FLOOR PLAN <br />A-122 <br />REFLECTED CEILING PLAN <br />A-211 <br />INTERIOR ELEVATIONS <br />A-212 <br />INTERIOR FINISH SCHEDULE, DOOR SCHEDULE, SPECIALTY <br />EQUIPMENT SCHEDULE <br />A-213 <br />ADA ACCESSIBLE MOUNTING HEIGHTS <br />A-214 <br />INTERIOR DETAILS <br />03 - MECHANICAL <br />M1.0 <br />HVAC GENERAL NOTES, SCHEDULES, AND FLOOR PLAN <br />04 - PLUMBING <br />P1.0 <br />PLUMBING GENERAL NOTES, SCHEDULES, AND FLOOR PLANS <br />05 - ELECTRICAL <br />E4.10 <br />2ND FLOOR PLAN SOUTH HEALTHCARE TI <br />EVERETT HEALTH CODE SUMMARY <br />CURRENT ADOPTED CODES: <br />2015 INTERNATIONAL BUILDING CODE (IBC) WITH APPENDIX E, & WAC 51-50 <br />2015 INTERNATIONAL MECHANICAL CODE (IMC) & WAC 51-52 <br />2015 UNIFORM PLUMBING CODE (UPC) & WAC 51-56 <br />2014 NATIONAL ELECTRICAL CODE (NFPA 70) & WAC 51-54 <br />2015 WASHINGTON STATE ENERGY CODE (WSEC) <br />2015 INTERNATIONAL ENERGY CONSERVATION CODE, WAC 51-11C <br />2015 INTERNATIONAL FIRE CODE (IFC) & WAC 51-54A <br />2009 ICC A117.1 <br />OCCUPANCY GROUPS: <br />BUSINESS B OCCUPANCY <br />TYPE OF CONSTRUCTION: IIB <br />FIRE -RESISTANCE RATING REQUIREMENTS (TABLE 601) 0 HR <br />ACCESSIBILITY <br />ACCESSIBILITY ROUTE AT LEAST ONE ACCESSIBLE ROUTE WITHIN THE SITE <br />(1104) SHALL BE PROVIDED FROM PUBLIC TRANSPORTATION <br />STOPS, ACCESSIBLE PARKING, ACCESSIBLE PASSENGER <br />LOADING ZONES, AND PUBLIC STREETS OR SIDEWALKS <br />TO THE ACCESSIBLE BUILDING ENTRANCE SERVED <br />PUBLIC ENTRANCE (1105.1) AT LEAST 60 PERCENT OF ALL PUBLIC ENTRANCES <br />SHALL BE ACCESSIBLE. <br />ACCESSIBLE PARKING IF BETWEEN 201-300 PROVIDED, REQUIRED MINIMUM <br />SPACES (TABLE 1106.1) NUMBER OF ACCESSIBLE SPACES TO BE 7. <br />VAN SPACES (1106.5) FOR EVERY SIX OR FRACTION OF SIX ACCESSIBLE <br />PARKING SPACES, AT LEAST ONE SHALL BE A VAN - <br />ACCESSIBLE PARKING SPACE. <br />TOTAL ACTUAL NUMBER OF PARKING SPACES: 299 <br />TOTAL ACCESSIBLE PARKING PROVIDED: 8 (2 VAN SPACES) <br />NO FINAL <br />APPROVAL <br />JUN 10 2022 <br />ARCHIVED <br />Permit#: <br />B1809-024 <br />Site Address: <br />4730 COLBY AVE <br />Owner: <br />YOUNG MENS CHRISTIAN ASSOCIATION <br />Tenant: <br />PROVIDENCE HEALTH <br />App. Date: <br />9/19/2018 <br />Proposed Use: <br />INITIAL BUILDOUTOFTI SPACE <br />Description: <br />INITIAL BUILDOUTOFTI SPACE IN NEW <br />YMCA <br />viewed By: <br />Date: <br />fFice Set <br />�oka Site Set Fire/Planning Set <br />1!- SHLL I MEASURES LESS I HAN 24 X36 , 11 IS A REDUCED PRINT. REDUCE SCALE ACCORDINGL <br />2 <br />00 <br />It <br />z00 <br />U rn <br />ws <br />m0 <br />F- <br />�S o <br />o <br />Cl) <br />U.3 W <br />rn <br />M — <br />°ct <br />I- (n <br />LLJ <br />Llp <br />cV Z <br />W <br />W > <br />ti¢ <br />co — <br />�Y U- <br />N U <br />c0 <br />Cl) <br />LO O <br />N <br />I- N <br />SEAL <br />NW <br />1� <br />W <br />U <br />rW <br />�} <br />Z <br />1U <br />® <br />w <br />Q <br />QQ <br />F- <br />I~- <br />i H <br />O <br />W <br />W <br />U W <br />W <br />0 <br />0 <br />W <br />W <br />^^ <br />I..L. <br />M CV <br />-tW� <br />DATE <br />09.20.2018 <br />BCRA NO. <br />14249 <br />DRAWN BY: <br />REVIEWED BY: <br />SHEET TITLE <br />COVER <br />BCRA 9 <br />©COPYRIGHT 2017 - BCRA, INC. ALL RIGHTS RESERVED <br />SHEET <br />Gml 01 <br />ISSUE FOR BID, PERMIT, AND <br />CONSTRUCTION <br />