a <br />co <br />0 <br />N <br />2 <br />W., <br />��'=' <br />F _ <br />--- <br />�p <br />I <br />f <br />u' <br />I ��y <br />/ I <br />r <br />tY_ <br />ILJ <br />�w <br />I � <br />Fi i� <br />i <br />� d Ir Ir <br />If rt <br />o o <br />QQQ Q <br />IF <br />ILI <br />-- <br />EGRESS PLAN - LEVEL 1 <br />1 /16" = 1'-0" <br />DEGRESS PLAN - LEVEL <br />1/16 =1-0 <br />20 OCCUPANTS <br />REQUIRED MIN: OCC X 0.2 = 4" <br />REQUIRED CLEAR: 32" CLEAR <br />PROVIDED: 42" -- - <br />1J J till <br />FIRE PROTECTION SYSTEMS <br />NONSEPARATED OCCUPANCY (508.3) <br />PORTABLE FIRE <br />WHERE REQUIRED: WITHIN 30 FEET OF COMMERCIAL COOKING <br />EXTINGUISHERS (906): <br />EQUIPMENT, IN AREAS WHERE FLAMMABLE OR COMBUSTIBLE <br />LIQUIDS ARE STORED, USED, OR DISPENSED, PER IFC TABLE 906.1, <br />SPECIAL -HAZARD AREAS. <br />PORTABLE FIRE EXTINGUISHERS SHALL BE LOCATED IN <br />CONSPICUOUS LOCATIONS WHERE THEY WILL BE READILY <br />ACCESSIBLE AND IMMEDIATELY AVAILABLE FOR USE. THESE <br />LOCATIONS SHALL BE ALONG NORMAL PATHS OF TRAVEL, UNLESS <br />THE FIRE CODE OFFICIAL DETERMINES THAT THE HAZARD POSED <br />INDICATES THE NEED FOR PLACEMENT AWAY FROM NORMAL PATHS <br />OF TRAVEL. <br />FIRE ALARM AND <br />A MANUAL FIRE ALARM SYSTEM THAT ACTIVATES THE OCCUPANT <br />DETECTION SYSTEMS (907): <br />NOTIFICATION SYSTEM IN ACCORDANCE WITH SECTION 907.5 SHALL <br />BE INSTALLED IN GROUP A OCCUPANCIES WHERE THE OCCUPANT <br />LOAD DUE TO THE ASSEMBLY OCCUPANCY IS 300 OR MORE. <br />EXCEPTION: MANUAL FIRE ALARM BOXES ARE NOT REQUIRED <br />WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN <br />AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH <br />SECTION 903.3.1.1 AND THE OCCUPANT NOTIFICATION APPLIANCES <br />WILL ACTIVATE THROUGHOUT THE NOTIFICATION ZONES UPON <br />SPRINKLER WATER FLOW. <br />ACTIVATION OF THE FIRE ALARM IN GROUP A OCCUPANCIES WITH <br />AN OCCUPANT LOAD OF 1,000 OR MORE SHALL INITIATE A SIGNAL <br />USING AN EMERGENCY VOICE/ALARM COMMUNICATIONS SYSTEM IN <br />ACCORDANCE WITH SECTION 907.5.2.2. <br />EXCEPTION: WHERE APPROVED, THE PRERECORDED <br />ANNOUNCEMENT IS ALLOWED TO BE MANUALLY DEACTIVATED FOR <br />A PERIOD OF TIME, NOT TO EXCEED 3 MINUTES, FOR THE SOLE <br />PURPOSE OF ALLOWING A LIVE VOICE ANNOUNCEMENT FROM AN <br />APPROVED, CONSTANTLY ATTENDED LOCATION <br />MEANS OF EGRESS <br />MAXIMUM FLOOR AREA FUNCTION OF SPACE FLOOR AREA (SF) PER OCCUPANT <br />ALLOWANCE PER OCCUPANT <br />OUTPATIENT AREAS 100/SF OCC GROSS <br />BUSINESS AREAS 100/SF OCC GROSS <br />STORAGE, MECHANICAL EQUIPMENT 300/SF OCC GROSS <br />OCCUPANT LOAD CALCULATION: SEE OCCUPANCY AND EXITING <br />EGRESS WIDTH BASED ON STAIRWAY = 0.3 INCHES PER OCCUPANT <br />COMPONENT (1005.3) OTHER EGRESS COMPONENT = 0.2 INCHES PER OCCUPANT <br />DISTRIBUTION OF EGRESS <br />WHERE MORE THAN ONE EXIT IS REQUIRED, THE MEANS OF EGRESS SHALL BE <br />CAPACITY (1005.5) <br />CONFIGURED SUCH THAT THE LOSS OF ANY ONE EXIT, SHALL NOT REDUCE THE AVAILABLE <br />CAPACITY TO LESS THAN 50% OF THE REQUIRED CAPACITY <br />SPACES WITH ONE EXIT OR <br />MAXIMUM OCCUPANT LOAD OF SPACE WITH ONE EXIT OR EXIT ACCESS DOORWAY: 49. <br />EXIT ACCESS DOORWAY <br />MAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE IS 100 FEET WITH SPRINKLER <br />SYSTEM (TABLE 1006.2.1) FOR W OCCUPANCY <br />EXIT AND EXIT ACCESS <br />WHERE TWO EXITS, EXIT ACCESS DOORWAYS, EXIT ACCESS STAIRWAYS OR RAMPS OR ANY <br />DOORWAY CONFIGURATION <br />COMBINATION THEREOF, ARE REQUIRED FROM ANY PORTION OF THE EXIT ACCESS, THEY <br />(1007.1.1) <br />SHALL BE PLACED A DISTANCE APART EQUAL TO NOT LESS THAN ONE-HALF OF THE LENGTH <br />OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE <br />SERVED MEASURED IN A STRAIGHT LINE BETWEEN THEM <br />EXCEPTION 2 <br />WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM, <br />THE SEPARATION DISTANCE SHALL BE NOT LESS THAN ONE-THIRD OF THE LENGTH OF THE <br />MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED. <br />ACCESSIBLE MEANS OF EGRESS <br />ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN ONE ACCESSIBLE MEANS <br />REQUIRED (1009.1) <br />OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS ARE REQUIRED BY SECTION <br />1015.1 OR 1021.1 FROM ANY ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE <br />SPACE SHALL BE SERVED BY NOT LESS THAN TWO ACCESSIBLE MEANS OF EGRESS. <br />SIZE OF DOORS (1010.1.1) <br />THE REQUIRED CAPACITY OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE <br />OCCUPANT LOAD THEREOF AND SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 32 <br />INCHES. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE <br />MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN <br />90 DEGREES. <br />DOOR SWING (1010.1.2) <br />EGRESS DOORS SHALL BE OF THE PIVOTED OR SIDE -HINGED SWINGING TYPE. DOORS <br />SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL WHERE SERVING A ROOM OR AREA <br />CONTAINING AN OCCUPANT LOAD OF 50 OR MORE <br />LANDINGS AT DOORS (1010.1.6) <br />LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE STAIRWAY OR THE <br />DOOR, WHICHEVER IS GREATER. DOORS IN THE FULLY OPEN POSITION SHALL NOT REDUCE <br />A REQUIRED DIMENSION BY MORE THAN 7". WHEN A LANDING SERVES AN OCCUPANT LOAD <br />OF 50 OR MORE, DOORS IN ANY POSITION SHALL NOT REDUCE THE LANDING TO LESS THAN <br />ONE-HALF ITS REQUIRED WIDTH. WHEN DOORS OPEN OVER LANDINGS, DOORS IN ANY <br />POSITION SHALL NOT REDUCE THE LANDING LENGTH TO LESS THAN 12". LANDINGS SHALL <br />HAVE A LENGTH MEASURED IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 44". <br />EXIT ACCESS TRAVEL DISTANCE <br />B OCCUPANCY WITH SPRINKLER SYSTEM: 300 FEET. <br />(1017.2) <br />EXIT DISCHARGE (1028.1) EXITS SHALL DISCHARGE DIRECTLY TO THE EXTERIOR OF THE BUILDING. THE EXIT <br />DISCHARGE SHALL BE AT GRADE OR SHALL PROVIDE A DIRECT PATH OF EGRESS TRAVEL <br />TO GRADE. THE EXIT DISCHARGE SHALL NOT REENTER A BUILDING <br />EXCEPTION 1 NOT MORE THAN 50 PERCENT OF THE NUMBER AND MINIMUM WIDTH OR REQUIRED <br />CAPACITY OF INTERIOR EXIT STAIRWAYS AND RAMPS IS PERMITTED TO EGRESS THROUGH <br />AREAS ON THE LEVEL OF DISCHARGE' <br />EXCEPTION 3 HORIZONTAL EXITS COMPLYING WITH SECTION 1026 SHALL NOT BE REQUIRED TO <br />DISCHARGE DIRECTLY TO THE EXTERIOR OF THE BUILDING <br />EXIT DISCHARGE (1028.5) THE EXIT DISCHARGE SHALL PROVIDE A DIRECT AND UNOBSTRUCTED ACCESS TO A PUBLIC <br />WAY. <br />OCCUPANCY/ EGRESS/ PLUMBING <br />OCCUPANCY: BUSINESS GROUP'B' <br />LOBBY <br />2 OCCUPANTS <br />@100 SF PER OCCUPANT <br />RECEPTION <br />3 OCCUPANTS <br />@100 SF PER OCCUPANT <br />PHYSICAL THERAPY <br />11 OCCUPANTS <br />@100 SF PER OCCUPANT <br />EXAM 1 <br />1 OCCUPANT <br />@100 SF PER OCCUPANT <br />EXAM 2 <br />1 OCCUPANT <br />@100 SF PER OCCUPANT <br />EXAM 3 <br />1 OCCUPANT <br />@100 SF PER OCCUPANT <br />EXAM 4 <br />1 OCCUPANT <br />la 100 SF PER OCCUPANT <br />TOTAL 20 OCCUPANTS ONE EXIT REQUIRED <br />PLUMBING FIXTURES REQUIRED: 1/25 OCC 1 W/C, 1 LAV <br />ONE GENDER -NEUTRAL ACCESSIBLE RESTROOM PROVIDED <br />Co <br />z� <br />S2¢ <br />o?: <br />mC) <br />0 <br />M <br />'n w <br />c� <br />v� <br />CV <br />COLd <br />`M Z <br />Z <br />CV <br />Lu <br />�Q <br />o U <br />v <br />�- <br />N U <br />cpn <br />M O <br />Lo <br />O <br />N <br />F- N <br />SEAL <br />�w <br />LL <br />U <br />1 <br />W <br />M <br />uj <br />U <br />U <br />3 <br />J <br />' 1z <br />W <br />W <br />U <br />I~- <br />> <br />J H <br />O <br />W <br />w <br />C) W <br />0 <br />j <br />W <br />MWN <br />� W rn <br />REVISIONS <br />DATE <br />09.20.2018 <br />BCRA NO. <br />14249 <br />DRAWN BY: <br />REVIEWED BY: <br />SHEET TITLE <br />CODE INFORMATION <br />BCRA <br />© COPYRIGHT 2017 - BCRA, INC. ALL RIGHTS RESERVED <br />SHEET <br />G-1 02 <br />ISSUE FOR BID, PERMIT, AND <br />CONSTRUCTION <br />IF SHEET MEASURES LESS THAN 24'X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY <br />